Loading…
Loading…
Tender ID
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
23 Mar 2026, 1:00 pmClosed
Executive Engineer ED Budgam KPDCL
Executive Engineer ED Budgam KPDCL
Face lifting/upgradation of Divisional/Sub Divisional offices of ED-Budgam KPDCL
2026_PDD_306282_1
138 of 2025-26
Open Tender
Electrical and Maintenance Works
Turn-key
6 days
ED Budgam, KPDCL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer ED Budgam KPDCL
₹10,000
23 Mar 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
16 Mar 2026 - 16 Mar 2026
Work items identified;
Wiring for Light point/Exhaust fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in existing surface/recessed Conduits(Havells/Polycab/Anchor/Finolex / Eq. make) (Including Cost of Conduit) laid in slabs with 01 No. of 6 Amp Modular Switch, Modular Plate, Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia) / Eq. make & shall be approved before execution of work.
Wiring for Ceiling fan point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable in surface/recessed Conduits(Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make) with 01 No. of 6 Amp Modular Switch, Modular Plate, Cover in front and suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia)/ Eq. make & shall be approved before execution of work.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC certified of Havells(crab-Tree)/Legrand(Myrics)/Anchor Rooma Plus/Schneider(Livia)/Eq.make & shall be approved before execution of work.
Providing & Fixing of M.S Ceiling Fan Fastener to be laid in Slab where required of Standard / Eq. make.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia) / Eq. make & shall be approved before execution of work (4/6/8/12 Module)
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia)/ Eq. make & shall be approved before execution of work
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make) & shall be approved before execution of work(2x10 sq mm+ 1x6 sq mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards).
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make) & shall be approved before execution of work(2x6 sq mm+ 1x6 sq mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards).
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Including Cost of Conduit)(Havells/Polycab/Anchor/Finolex / Eq. make) & shall be approved before execution of work(2x2.5 sq mm+ 1x2.5 sq mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards).
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Livia)/ Eq. make/ Eq. make
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP, 240V, "C" Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB _DB Complete with connections.(L&T/Siemens/Legrand/ABB/Schneider / Eq. make)
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C Curve 10K, Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider / Eq. make(100 Amp).
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C Curve 10K, Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider / Eq. make(40Amp).
Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C Curve 10K, Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/ABB/Schneider / Eq. make(63Amp).
Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required.(L&T/Siemens/Legrand/ ABB /Schneider / Eq. make)
Supply/Installation/Testing and Commissioning of 12W + LED Surface Mounted Panel light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F. >0.95, THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Wipro/H G/Jaguar/Bajaj / Eq. make
Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/wt, LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety Factor >0.95, THD(I) <10% , driver current <=750mA drier should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K, Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by
Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required USHA/Havells/Polycab/Orient / Eq. make. (5-Star)
Supply/Installation/Testing and Commissioning of ~~200mm~~ Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Havells/Polycab/Orient./ Eq make (Min 3-Star)
Supply/Laying of 25/32mm Dia PVC Conduit of Anchor/Ravinder/Polypack/Finolex / Eq. make with other accessories like bends,etc complete to be laid in wall for downs and finishing the surface to its original shape by cement mortar plastering/Wall Putty/Tile with same Colour/Paint etc
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required Havells/Legrand/Panasonic/Anchor/Schneider / Eq. make
Supplying, installation,Testing & Commissioning of 1.5 Ton AC With automatic Stabilizer of standard make including the cost of fitting/fixtures complete in all respects .
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR electrification of Divisional/Sub Divisional office of ED-Budgam KPDCL.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.71 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 1.62 MB
BOQ_994493.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .