Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-Finance | L1 | Accepted-Finance Lowest rate | |
| 2 | L2₹22.0 L+₹11,164.93 (0.51%)Rejected-Finance | L2 | Rejected-Finance Higher rate | |
| 3 | L3₹22.2 L+₹30,867.81 (1.41%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L3 | Rejected-Finance Highest rate |
| Sl No | Description | Qty | Unit | ORIENTAL ENGINEERING CO. L3 | JDJ ENTERPRISE. A UNIT OF JDJ TRADERS PRIVATE LIMITED L2 | ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, delivery at site of Membrane element for RO unit,
Capacity 2000 lit/hr. Suitable for installation in RO vessel
diameter 8 " & length 40" as per following specification:-
a)Permeate Flow: - Minimum 10000 gpd (3.75 m³ /d)
b) salt Rejection :- (99.5% minimum)
c) Configuration : - Spiral wound
d) Membrane polymer:- Composite Polyamide
e) Nominal membrane Area:- Minimum 365 ft²
(33.9m²)
f) Maximum applied pressure:- above 450 psi
g) Maximum operation temperature :- Not above
122°F (50°C)
h) pH range, continuous (Cleaning) :- 2-11 (1-13)
i) Maximum Feed water Turbidity :- Upto 1.0 NTU
j) Maximum Feed water SDI (15 mins) :- Upto 5.0
k) Maximum Feed Flow:- 75 GPM (17.0 m³ /h )
l) Minimum Ratio of Concentrate to permeate
Flow any Element:- 5.1
m) Maximum pressure drop for Each Element:-10
psi
(Make- Hydranautics /Dow/Toray/GE/Any other approved make. | 3 | set | 2,41,889.7 ₹7,25,669.1 | 2,39,742.75 ₹7,19,228.25 | 2,38,526.15 ₹7,15,578.45 Lowest |
| 2.10Supply, delivery of UF unit for removing all undisclosed impurities including suspended solids, colidall impurities having Feed Pressure-5 Bar, Operating Tran membrane Pressure -2 psig, Maximum Backwash- 20 psig as per following specification: a) Filtrate Flow- 12.1-29.5 gpm (2.7-6.7m³/hr) b) Filtrate Turbidity-≥00.7 NTU c)Virus removal-≥ 4 log d) Bacteria removal-≥ 4 log e) Configaration :- Capillary Ultrarafitration Module f) Membrane Polymar:- Hydrophilic Poly thersulfone g) Nominal Membrance Area :- 500 ft²(46m² ) or above h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055" (1.4mm) i) Pore size:- 0.02 micron or less j) Typical Filtrate Flux Range:- 35-85 gfd (59 145 l/m²/h) k) Maximum Applied Feed Pressure. 73 psig (5bar) l) Maximum Transmenibrane Pressure - 20psig (1.4 bar) m) Maximum backwash transtnembrance Pressure :- 20 psig (1.4 bar) n) Instantaneous Chlorine Tolerance :- 200 ppm p) maximum chlorine Expossure :-200.000ppm-hrs q) maximum instantaneous Feed Turbidity :- 100 NTU r) Maximum Operating Temperature:- 104° F s) pH operatin range:- 4.0-10.0 t) Clraning pH Range- 1.5-13.0 | ||||||
| 2.20 | u) Operating Mode:- Inside to Outside Filtration
Direct flow of Crossflow.
v) Backwash flux-100-150 gfd (170-255 l/m²/hr)
w) Backwash Duration -30-60 seconds.
x) Backwash Frequency-20-60 minutes.
y) Chemical Enhanced Backwash Frequrncy-0-4
times per day
z) Chemical Enhanced Backwash Duration-1-30
minutes
z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or ,
NH₂CL
z2) Cleaning Chemicals -NaOH, HCL, H₂SO₄, or
Citric Acid
(Make - Hydranautics/Dow/Toray/IMT/any other approved make) | 2 | LS | 5,34,631.5 ₹10,69,263 | 5,29,886.25 ₹10,59,772.5 | 5,27,197.28 ₹10,54,394.56 Lowest |
| 3.00 | Installation and Commissioning of Membrane element for RO unit in its existing position after dismantling of damaged/defective unit including testing complete as per direction of EIC. | 3 | LS | 7,619.2 ₹22,857.6 | 7,551.57 ₹22,654.71 | 7,513.25 ₹22,539.75 Lowest |
| 4.00 | Installation and Commissioning of UF unit in its existing position after dismantling of damaged/defective unit including testing complete as per direction of EIC. | 2 | LS | 22,409.4 ₹44,818.8 | 22,210.5 ₹44,421 | 22,097.79 ₹44,195.58 Lowest |
| 5.00 | Add: GST @ 18% | 1 | item | 3,35,269.53 ₹3,35,269.53 | 3,32,293.76 ₹3,32,293.76 | 3,30,607.5 ₹3,30,607.5 Lowest |
| 6.00 | Add: LWC @ 1% | 1 | item | 21,978.78 ₹21,978.78 | 21,783.7 ₹21,783.7 | 21,673.16 ₹21,673.16 Lowest |
Tender Value
Refer Docs
EMD Value
₹45,600
Closing Date
25 Sept 2026, 5:00 pmClosed
Executive Engineer Eastern Mechanical Division P.
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG Kol 73
Supply, delivery and installation of Fast Moving Spares of MTU-9 under Eastern Mechanical Division, P.H.E. Dte. in the Dist.- 24Pgs(N).
2026_PHED_5023152_8
WBPHED/EE/EMD/NIET-07/2026-27
Open Tender
MECHANICAL
Item Rate
30 days
Executive Engineer EMD, PHED, P-16, CIT ANNEX BLDG
Please refer Tender documents.
6 documents required · 6 mandatory
₹45,600
29 Sept 2026
10 Sept 2026
28 Sept 2026
10 Sept 2026
25 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery at site of Membrane element for RO unit,
Capacity 2000 lit/hr. Suitable for installation in RO vessel
diameter 8 " & length 40" as per following specification:-
a)Permeate Flow: - Minimum 10000 gpd (3.75 m³ /d)
b) salt Rejection :- (99.5% minimum)
c) Configuration : - Spiral wound
d) Membrane polymer:- Composite Polyamide
e) Nominal membrane Area:- Minimum 365 ft²
(33.9m²)
f) Maximum applied pressure:- above 450 psi
g) Maximum operation temperature :- Not above
122°F (50°C)
h) pH range, continuous (Cleaning) :- 2-11 (1-13)
i) Maximum Feed water Turbidity :- Upto 1.0 NTU
j) Maximum Feed water SDI (15 mins) :- Upto 5.0
k) Maximum Feed Flow:- 75 GPM (17.0 m³ /h )
l) Minimum Ratio of Concentrate to permeate
Flow any Element:- 5.1
m) Maximum pressure drop for Each Element:-10
psi
(Make- Hydranautics /Dow/Toray/GE/Any other approved make. | 3 | set | - | - |
| 2.1 | Supply, delivery of UF unit for removing all
undisclosed impurities including suspended solids,
colidall impurities having Feed Pressure-5 Bar,
Operating Tran membrane Pressure -2 psig, Maximum
Backwash- 20 psig as per following specification:
a) Filtrate Flow- 12.1-29.5 gpm (2.7-6.7m³/hr)
b) Filtrate Turbidity-≥00.7 NTU
c)Virus removal-≥ 4 log
d) Bacteria removal-≥ 4 log
e) Configaration :- Capillary Ultrarafitration Module
f) Membrane Polymar:- Hydrophilic Poly
thersulfone
g) Nominal Membrance Area :- 500 ft²(46m² ) or
above
h) Fiber Dimensions- ID 0.031" (0.8mm) OD 0.055"
(1.4mm)
i) Pore size:- 0.02 micron or less
j) Typical Filtrate Flux Range:- 35-85 gfd (59
145 l/m²/h)
k) Maximum Applied Feed Pressure. 73 psig (5bar)
l) Maximum Transmenibrane Pressure - 20psig (1.4
bar)
m) Maximum backwash transtnembrance Pressure :- 20 psig (1.4 bar)
n) Instantaneous Chlorine Tolerance :- 200 ppm
p) maximum chlorine Expossure :-200.000ppm-hrs
q) maximum instantaneous Feed Turbidity :- 100
NTU
r) Maximum Operating Temperature:- 104° F
s) pH operatin range:- 4.0-10.0
t) Clraning pH Range- 1.5-13.0 | - | - | - | - |
| 2.2 | u) Operating Mode:- Inside to Outside Filtration
Direct flow of Crossflow.
v) Backwash flux-100-150 gfd (170-255 l/m²/hr)
w) Backwash Duration -30-60 seconds.
x) Backwash Frequency-20-60 minutes.
y) Chemical Enhanced Backwash Frequrncy-0-4
times per day
z) Chemical Enhanced Backwash Duration-1-30
minutes
z1) Disinfection Chemicals -Na0CL, H₂o₂, CLO₂, or ,
NH₂CL
z2) Cleaning Chemicals -NaOH, HCL, H₂SO₄, or
Citric Acid
(Make - Hydranautics/Dow/Toray/IMT/any other approved make) | 2 | LS | - | - |
| 3 | Installation and Commissioning of Membrane element for RO unit in its existing position after dismantling of damaged/defective unit including testing complete as per direction of EIC. | 3 | LS | - | - |
| 4 | Installation and Commissioning of UF unit in its existing position after dismantling of damaged/defective unit including testing complete as per direction of EIC. | 2 | LS | - | - |
| 5 | Add: GST @ 18% | 1 | item | - | - |
| 6 | Add: LWC @ 1% | 1 | item | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
Tendernotice_2.pdf
PDF • 1.65 MB
Tendernotice_3.pdf
PDF • 2.33 MB
Tendernotice_4.pdf
PDF • 0.86 MB
BOQ_5106682.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .