| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹12.6 LAdmitted-Finance | -1.10% | ₹12.6 L | L1 | Admitted-Finance |
| 2 | L2₹12.7 LAdmitted-Finance BHAPKAR PATIL PLOT NO 24 GURHSHIP HOUSING SOCIETY SATBHAL MALA DEHIGATE AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | +0.00% | ₹12.7 L | L2 | Admitted-Finance |
| 3 | L3₹12.9 LAdmitted-Finance | +1.56% | ₹12.9 L | L3 | Admitted-Finance |
Tender Value
₹12.7 L
EMD Value
₹12,712
Closing Date
16 Mar 2026, 3:00 pmClosed
EE RWS ZP AHILYANAGAR
EE RWS ZP AHILYANAGAR
Providing Stabilizer / VFD starter at Rajur Tal - Akole Dist-Ahilyanagar
2026_AHMED_1285123_1
ZP/RWS/TENDER/2025-26
Open Tender
Pumps/Motors
180 days
AHILYANAGAR
AS PER NIT
2 documents required · 2 mandatory
₹590
₹12,712
30 Mar 2026
9 Mar 2026
17 Mar 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
Rewinding of motor Providing, erecting and giving test and trial of Heavy Duty Variable Frequency Drive with Speed and Torque Control, Built-in by pass contactor and all Motor Protections and external Semi-conductor fuses, Display and keypad, bus bars etc complete assembled in an SWG 14 IP23 and above Enclosure. CE Certified and Complient to EN 61800-5-1:2007 Application:- General Purpose Water Pumping Operational Voltage 380-600VAC Control Voltage 110-250VAC Harmonics Compliance: Built-in optimized dual DC choke / AC Choke as standard in AC560-01 (R3-R9) meets the requirements of IEC 61000-3-12:2011. Temp Range: -40 to 70 Deg C, 5% to 95% RH, Air Cooled with third party inspection and as per detailed specification. For 100 HP
VFD Starter Providing, erecting and giving test and trial of Heavy Duty Variable Frequency Drive with Speed and Torque Contro, Built-in by pass contactor and all Motor Protections and external Semi-conductor fuses, Display and keypad,bus bars etc complete assembled in an SWG 14 IP23 and above Enclosure. CE Certified and Complient to EN 61800-5-1:2007 Application:- General Purpose Water Pumping Operational Voltage 380-600VAC Control Voltage 110-250VAC Harmonics Compliance: Built-in optimized dual DC choke / AC Choke as standard in AC560-01 (R3-R9) meets the requirements of IEC 61000-3-12:2011. Temp Range -40 to 70 Deg C, 5% to 95% RH, Air Cooled with third party Inspection and as per detailed spacification.
Cable Providing, erecting.terminating XLPE/PVC insulated armoured aluminium conductor Of following sizes 1100 V grade cable as per detailed specification attached. Supplying, erecting & terminating XLPE armoured cable 3% core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per spec
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
BOQ_2210174.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid