MUKESH KUMAR
SUPERINTENDENT ENGINEER
CONSTRUCTION OF MULAKATI KAKSH AT DISTRICT JAIL SIWAN IN THE DISTRICT OF SIWAN WITH ELECTRIFICATION
130450
NIT-03/2026-27/GR-03
Open Tender
GENERAL
Patna
• Character Certificate No. with Issue date.
• Place of Registration
• VAT Registration No.
• PAN No.
• Necessary Undertakings
• Bidding Capacity (Provide the Amount)
• GST DETAILS
GENERAL
PERCENTAGE
L1
1
21 documents required · 21 mandatory
₹5,000
Processing Fee: 590
₹60,386
CE, BPBCC, Patna
2 May 2026
2 May 2026
19 May 2026
2 May 2026
18 May 2026
2 May 2026
8 May 2026
Cause of Dispute
Owned/Leased / to be procured
Year of Experience (General)
Owned / leased / to be procured
Sub-contractor( Name and Address)
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab up to 0.50 sqm.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including stainless steel butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Structural steel work in singal section fixed without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying vitrifed floor tiles in different sizes { thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete: Size of Tile 60 x 60 cm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete,including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap): 300 mm dia piles.
Per bag
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Per bag
DESCRIPTION
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. Group C
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x6.0 mm2 + 1x6.0mm2)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as req u ired.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' I25 A,16 KA, TPMCCB
Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required. 100 A
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) 4 way ( 4 + 12 ), Double door, horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A,.TP
Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 40 A to 63 A, TP&N
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc.as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 18 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Supplying and fixing of following type lamp in the existing electrical fitting/fixtures etc. as required. 9/10 watt LED lamp
Laying of one number additional PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 35 sq. mm, 3.5 core
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
TOTAL Rs P
DESCRIPTION
Earthwork in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead upto 50M and lift upto 1.5M.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roots, landings, balcnies and access platform.
Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cost in situ)
Centring and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth bams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for: Columns,Pillars, Piers, Abutments, Posts and Struts
Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade,Chajjas, corbels etc. including edges
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 8mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 10mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 12mm dia.
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete:Thermo-Mechanically Treated bars (FE-500) 16mm dia.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:Add or deduct for providing richer or leaner mixes respectively at all floor levels: Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Walls columns, pillars, posts cind struts: Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete :All work upto plinth level:All works above plinth level upto floor V level : Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.:Add or deduct for providing richer or leaner mixes respectively at all floor levels:Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level. Cement mortar 1 : 3 (1 cement : 3 coarse sand)
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly. plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. but excluding carriage cost of bricks, sand and jhama metal.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade:Area of slab up to 0.50 sqm.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including stainless steel butt hinges with necessary screws.
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete: Fixed to steel windows by welding.
Providing and fixing alluminium sliding door bolt anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to rquired colour and shade with nuts and screws etc. complete : 300 x 16mm
Providing and fixing alluminium sliding tower bolt anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with nuts and screws etc. complete : 300 x 10mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc.complete: 125mm
Providing and fixing alluminium hanging floor door stopper anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete : Twin rubber stopper
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.
Structural steel work in singal section fixed without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
Providing and fixing T-iron frames for doors. windows and ventilators of mils steel Tee-sections, joints miltred and welded with 15 x 3 mm lugs 10 cm long embedded in cement concerete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including.
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying vitrifed floor tiles in different sizes { thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete: Size of Tile 60 x 60 cm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600 x 600 mm.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
12mm cement plaster of mix: 1:6 (1 Cement : 6 coarse sand)
6mm cement plaster to ceilling of Mix : 1:4 (1 cement : 4 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give and even shade: New work (two or more coats) over and including priming coat with cement primer
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete,including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap): 300 mm dia piles.
Per bag
DESCRIPTION
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:1.5:3(1 Cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete.
Providing designation 100A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/I.
Per bag
DESCRIPTION
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
DESCRIPTION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable size G.I. box etc as required. Group C
Wiring for light/Power plug with 2x4 Sq.mm FR PVC insulated Copper conductor single core cable in surface recessed PVC conduit along with 1 No. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (2 x2.5mm2 + 1x2.5 mm2 earth wire)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of PVC insulated Copper conductor single core cable in surface recessed PVC conduit as required. Submain (4x6.0 mm2 + 1x6.0mm2)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as req u ired.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection etc. as required.
Supplying and fixing suitable size G.I. Box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' I25 A,16 KA, TPMCCB
Providing and fixing following capacity four pole ON-load panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required. 100 A
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required, (But without MCB/RCCB/lsolator) 4 way ( 4 + 12 ), Double door, horizontal type
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 6 A to 32'A, Single pole
Supplying and fixing following rating 240/415 volts "C" curve mainiature Circuit Breaker suitable for inductive load of Following poles in the existing MCB, DB, complete with connections testing and commissioning etc. as required. 40 A to 63 A,.TP
Supptying and fixing following rating, 24Al4L5 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required' 40 A to 63 A, TP&N
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc.as required.
Supplying and fixing 4'X18 wat[ LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required.
Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 Im/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 18 watt
Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required. 90 watt
Supplying and fixing of following type lamp in the existing electrical fitting/fixtures etc. as required. 9/10 watt LED lamp
Laying of one number additional PVC insulated and pVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 35 sq. mm and upto 95 sq. mm
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 35 sq. mm, 3.5 core
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 270 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required. 300 mm sweep
TOTAL Rs P
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
SPECIAL CONDITION.doc
NIT • 0.07 MB
e NIT 03 2026-27.pdf
NIT • 2.47 MB
GR-03 TECH-03 2026-27.xls
NIT • 0.04 MB
GR-03 BOQ-03 2026-27.xls
NIT • 0.09 MB
GR-03 BOQ-03 2026-27.xls
NIT • 0.09 MB
Download all tender documents and submit your bid