| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹16.1 L+₹10,932 (0.68%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹16.3 L+₹26,648 (1.66%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹17.1 L+₹1.1 L (6.70%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹18.5 L+₹2.4 L (15.1%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-Finance not being lowest |
Tender Value
₹20.0 L
EMD Value
₹39,980
Closing Date
26 Feb 2021, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
REPAIR/ REPLACEMENT OF LT PANELS AND CONNECTED ITEMS AT CME
2021_MES_420147_1
8177/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class E b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹39,980
Yes
19 Apr 2021
8 Feb 2021
1 Mar 2021
8 Feb 2021
26 Feb 2021
20 Feb 2021
9 Feb 2021 - 19 Feb 2021
Amount
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, cubical of size 1.5 x 0.50 x1.2 (approx) with front made of and rear opening, hinged door for front,and rear with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides , cable glands and PCC foundation with PCC 1 : 2 : 4, type B1 including dismantling of old unserviceable and to accommodate and including the following accessories:-
Copper bus bar rectangular 600 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job
MCCB 400 Amps, TPN, 415 Volts, 50 Hz, 50 KA- 01 No (Incoming)
MCCB 250 Amps, TP, 415 Volts, 50 Hz, 36KA - 02 Nos (Outgoing)
MCCB 200 Amps, TP, 415 Volts, 50 Hz, 25KA - 02 Nos ( Outgoing)
MCB TP 40A - 02 Nos
MCB SPN 32/40A - 02 Nos
RYB LED Indicator Lamp- Set of Three-01
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, with front made of and rear opening, hinged door for front, rear and cubicle doors with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides , cable glands and PCC foundation with PCC 1 : 2 : 4, type B1 , of suitable size 1.00 x 0.50 x 1.25 mtr (approx) including dismantling of old unserviceable and to accommodate and including the following accessories:-
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job
MCCB 250 Amps, TPN, 415 Volts, 50 Hz , 36 KA - 01 No ( Incoming)
MCCB 125 Amps, TP, 415 Volts, 50 Hz , 36 KA - 04 Nos (Outgoing)
RYB LED Indicator Lamp- Set of Three-01
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, with front made of and rear opening, hinged door for front, rear and cubicle doors with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1 : 2 : 4, type B1, of suitable size 1.00 x 0.50 x 1.25 mtr (approx) including dismantling of old unserviceable and to accommodate and including the following accessories:-
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job
RYB LED Indicator Lamp- Set of Three-01
MCCBs 250 Amps TPN - 01 No (Incoming)
MCCBs 63 Amps TP - 04 Nos (Outgoing)
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs /thimbles on either ends of cable.
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, with front made of and rear opening, hinged door for front, rear and cubicle doors with MS angle iron frame 40 x 40 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides , cable glands and PCC foundation with PCC 1 : 2 : 4, type B1 , of suitable size 0.65 x 0.50 x -0.70 mtr (approx) including dismantling of old unserviceable to accommodate and including the following accessories:
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job
RYB LED Indicator Lamp- Set of Three - 01
MCCB TPN 415 Volts 50 Hz 100 Amps - 01
3 pole Power contactor 415 Volts, ML - 4 100 Amps cap - 01
Street light timer analogue type - 1 No.
MCB SPN 32 Amps :- 01 No.
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/ thimbles on either ends of cable.
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, with front made of and rear opening, hinged door for front, rear and cubicle doors with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1 : 2 : 4, type B1, of suitable size 1.00 x 0.50 x 1.25 mtr (approx) including dismantling of old unserviceable and to accommodate and including the following accessories:-
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves. - 01 job
RYB LED Indicator Lamp- Set of Three - 01
MCCBs 200 Amps TPN - 01 No (Incoming)
MCCBs 40 Amps TP - 07 Nos (Outgoing)
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Supply, install, connect, test and commissioning of factory made, dust/vermin, weather proof self ventilated, with front made of and rear opening, hinged door for front, rear and cubicle doors with MS angle iron frame 50 x 50 x 5mm for base support, 3.15 mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubicle type, floor mounted, double door with neoprene gasket and locking arrangement including painting with powder coated on steel surfaces internally & externally and provision of two Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1 : 2 : 4, type B1, of suitable size 1.00 x 0.50 x 1.25 mtr (approx) including dismantling of old unserviceable and to accommodate and including the following accessories:-
Copper bus bar rectangular 300 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves. - 01 job
RYB LED Indicator Lamp- Set of Three-01
MCCBs 100 Amps TPN - 01 No (Incoming)
MCBs 40 Amps SPN - 15 Nos (Outgoing)
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Supply & fix MCCB 400 Amp TPN, 415 Volts, 50HZ, 50 KA complete all as specified and directed.
Supply & fix MCCB 250 Amp TPN, 415 Volts, 50HZ, 36 KA complete all as specified and directed.
Supply & fix MCCB 250 Amp TP, 415 Volts, 50HZ, 36 KA complete all as specified and directed.
Supply & fix MCCB 100 Amp TPN, 415 Volts, 50HZ, 36 KA complete all as specified and directed.
Supply & fix MCCB 160 Amp TP, 415 Volts, 50HZ, 36 KA complete all as specified and directed.
Supply & fix MCCB 40 to 63 Amp Amp TP, 415 Volts, 50HZ, 36 KA complete all as specified and directed.
M & L for Preparation of old painted surfaces of LT Panel or Street light Panel covered by dust and other deposited materials by cleaning from Panel of Size upto 100 X 100 X 50 cm including Repair of panel door, hinged nut bolts clamp etc. painting with one coat of aluminium paint complete all as specified and directed.
Supply and fixing in replacement three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil Make L&T Model MNX 70 Three pole contactor all as specified and directed.
Supply and fixing in replacement Analog type street light timer switch time setting incl inbuilt backup operated on 415 volts AC 50Hz Make L&T or equivalent approved make all as specified and directed.
M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iron strip of 25 x 4 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 CM made of RCC 1:2:4 type B1, reinforced with 6 mm dia MS bars on both ways with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt in alternate layers all around the earth plate, excavation in any type of strate removal of surplus soil and returning filling in all as required at site all as specified in electrical plate No 3 of SSR Part-I and directed by Engr-in-Charge.
Supply & fix MCCB 125 Amp TP, 415 Volts, 50HZ, 36 KA complete all as specified and directed
Supply and fixing in replacement existing aluminium bus bar rectangular 400 to 600 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators including nut, bolts with colour coding PVC sleeves all as specified and directed.
Supply and fixing in repalcement existing aluminium bus bar rectangular 250 to 300 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epxy insulators nut, bolts with colour coding PVC all as specified and directed.
Supply and fixing in replacement aluminium lugs of size 16 sqmm to 50 sqmm and tightening of all connecting points, cable connection complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement aluminium lugs of size 70 sqmm to 120 sqmm and tightening of all connecting points, cable connection complete all as specified and directed by Engineer-in-Charge
M & L chemical earthing with copper earthplate electrode 900x600x5mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copperstrip 32x6 mm by means of nuts, bolts, checknuts, washers of brass or copper all as shown in electrical plate No. 3 of SSR part-I connected to earthing test point including excavation/ earth work in any starta PCC (1:3:6) type C1 including necessary formwork mould for fair and even surfaces inclduing with precast RCC chamber cover slab (1:2:4) type B1 reinforced with 6 mm dia MS bars on both wings, necessary chemicals for improvement of earth resistance upto below 1 ohm without GI protection pipe specified and directed by Engineer-in-Charge. Note : Earth resistance of chemical earth should be below 1 ohm.
Mahindra Electric Stores
Techmat trading solution
M/S. Niksun Electro-Infra Private Limited
M/S - KRUPA ELECTRICALS
M/s Vijay Airconditioning Pvt Ltd
CHAITANYA WINDWELL
Sachin Electricals
PURVA ELECTRICALS AND ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .