| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹3.3 L
EMD Value
₹6,620
Closing Date
26 Mar 2022, 2:00 pmClosed
Executive Engineer PWD Electri
Office of the Executive Engineer PWD Electric Division Jammu
Improvement Upgradation Installation of Pannel for Solar System and Shifting of existing LT Pannel to another site of D.C Office Complex Jammu.
2022_PWDJK_165018_1
e-NIT No.EDJ/282of 2021-2022Dated19-03-2022
Open Tender
Electrical Works
Turn-key
15 days
JAMMU
AS PER NIT
2 documents required · 2 mandatory
₹600
Executive Engineer PWD Electric div jammu
₹6,620
Yes
7 Apr 2022
21 Mar 2022
26 Mar 2022
21 Mar 2022
26 Mar 2022
21 Mar 2022
Amount
Wiring for light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)
Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connections but excluding modular plate etc. as required.
5/6 amp switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing (two module) stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 5 amps to 32 amps rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolater)
6 way (Double door )
Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts,on surface/recess complete with tinned copper busbar, neutral bus bar, earth bar,din bar, interconnection, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolater)
4 Way (4+12), (Double door )
Supplying and fixing of 10 watt LED batten fitting 2 ft long including connections etc. as required.
Supplying and fixing of surface mounted 18/20 watt LED batten tube fiiting 4 feet long including connections etc as required.
Supplying & fixing Recess/surface mounted LED 36 watt Luminarie with full diffuser (size 600mm x 600 mm).
Supplying and fixing following rating 240/415 volts "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SPN 40 Amp.
SPN 63 Amp
TPN 63 Amp.
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board inculding drilling holes in cubicle panel, making connection etc. as required.
MCCB-250 Amp- 36 KA- FP ICU=ICS=100%
MCCB-100 Amp- 30 KA- FP ICU=ICS=100%
MCCB- 125 Amp- 36 KA- FP ICU=ICS=100%
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground/.cable tray as per site conditions as required.
70 sq. mm x 3.5 core Armoured.
95 sq. mm x 3.5 core Armoured.
Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and having ROHS certification. The earthing pit should be covered with PVC cover.
Providing and laying of 25 x 5 mm copper strip from copper rod up-to the main panel.
Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode shall be tested from CPRI.
Providing and laying of 25 x 5 mm G.I strip from G.I rod upto the main panel.
Supplying & fixing of following items for use in Networking system as required
1 Mtr Patch Cords
RJ 45 Complete with IO box complete
Network switch 24 Port
6 U rack( with cooling fan and power strip)
Digital Video Recorder 16 channel of IP , delivering 1920x1080 (1080P), 2HD video resolution, H.265. Real time video recording at 4CIF resolution.
4TB Hard disk
Shifting Of Existing Pannel due to Installation Of Lift at D.C office Jammu
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .