Loading…
Loading…
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
22 Jul 2026, 6:00 pm
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINT OF UNSERVICEABLE INTERNAL WIRING ELECTRICAL FITTINGS, CEILING/ EXHAUST FANS/ SUMMER APPLIANCES, DAY TO DAY ELECTRICAL COMPLAINTS AT D, E, F TYPE OFFICERS QTRS, SCIENTIST HOSTEL, DLOMI AND SWIMMING POOL AT DRDO TOWNSHIP KBAGH HYDERABAD
2026_MES_775432_1
8221
Open Tender
Electrical and Maintenance Works
270 days
GE I R and D Kanchanbagh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
30 Jun 2026
30 Jun 2026
24 Jul 2026
30 Jun 2026
22 Jul 2026
15 Jul 2026
1 Jul 2026 - 8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair / maintenance of internal/Building light fittings of any type like tube lights / wall bracket light fittings / ceiling lights / mirror lights/ high& Medium bay lights in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like, tube rod, side holders, holders, lamps etc all as directed by Engr-in-charge. Note: (i) The rate against the above mentioned item is deemed for cost of labour only.
(ii) Cost of spares like, capacitor, lamp holder, connector, connection wire, LED tube, Bulbs etc, replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. | 450 | Each | - | - |
| 1.01 | (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.
(vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below.
(vii) The contractor should submit the copy of qualification,Experience as Electrician and police verification certificates while sigining the site orders.
(viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the electrical defects.Any complaints pending for more than 72 hours, a penalty of Rs 100 per day per docket would be recovered. | - | - | - | - |
| 2 | S&F LED tube 20Watt, 6500K CCT,professional luminaries with luminous efficiency not less than 120Lm/watt, Single side connection with < 10% THD.
Make: Havells/Polycab/Philips/Wipro | 600 | Each | - | - |
| 3 | S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20W, 6500K CCT, aluminium extruded body and polycarbonate diffuser, <10%THD, integral electronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings all as specified and directed. .
Make : Havells/Polycab/Philips/Wipro | 600 | Each | - | - |
| 4 | S&F in replacment LED PLL lamp Hercules 18Watt, professional luminaries single side connection with < 10% THD.
Make: Make:Havells/ Jaquar/Crompton/Polycab/wipro | 10 | Each | - | - |
| 5 | S&F in replacment indoor industrial type recess mounted LED Surface mounted for POP ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed
Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro | 90 | Each | - | - |
| 6 | S&F in replacment indoor industrial type recess mounted LED Surface mounted for Recessed Mounting ceiling round downlight with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency.15W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete removing unserviceable fittings all as specified and directed
Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro | 40 | Each | - | - |
| 7 | S&F led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete.
Make:Havells/ Jaquar/Crompton/Polycab/wipro | 100 | Each | - | - |
| 8 | Supply & Fix in replacement recess mounted LED luminaire 36W 2'x2', 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for POP ceiling or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed.
Make : Make:Havells/ Jaquar/Crompton/Polycab/wipro | 20 | Each | - | - |
| 9 | Supply & Fix recess mounted LED luminaire 36W 4'x1' of size 1195x295x70 mm, 5700K CCT, luminous efficacy of not less than 120lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size including making good to the disturbed portion of ceiling complete removing unserviceable fittings all specified and directed.
Make:Make:Havells/ Jaquar/Crompton/Polycab/wipro | 20 | Each | - | - |