Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.5 LAccepted-AOC A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹60.9 L+₹96,180 (1.60%)Rejected-Finance PART III GANESH MURTHI NAGAR CAPT PRAKASH PETHE MARG CUFF PARADE ROAD COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹61.7 L+₹1.7 L (2.83%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹64.0 L+₹4.0 L (6.66%)Rejected-Finance | L4 | Rejected-Finance Other than being lowest | |
| 5 | L5₹73.3 L+₹13.4 L (22.3%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L5 | Rejected-Finance Other than being lowest |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
18 Sept 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR/ MAINTENANCE AND REPLACEMENT OF EXTERNAL WATER SUPPLY PIPE LINE, GATE VALVE, SLUICE VALVE, OH TANK, SUBMERSIBLE PUMP MOTORS INCLUDING CLEANING OF UG/OH SUMPS, REWINDING OF CENTRIFUGAL/ MONOBLOCK PUMP SETS/ MOTORS AND OTHER ASSOCIATED WORKS AT
2024_MES_666771_1
8793/CWE (NW) Mumbai/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) NOFRA
Class B
Category a (ii)
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) NOFRA
₹1.8 L
25 Nov 2024
19 Jul 2024
21 Sept 2024
19 Jul 2024
18 Sept 2024
9 Aug 2024
19 Jul 2024 - 8 Aug 2024
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /evection of pole/stay pit excavation/pipe line complete all as specified and directed by Engr in Charge.
Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engr in Charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engr in Charge.
Material & labour for PCC 1:3:6 type C2 (using 20 mm graded crushed stone aggregate) for filling in hard standing/ plinth protection of semi under tank and suport to main water supply line all as directed by Engineer-in-Charge.
Material & labour for construciton of brick masonry valve pit of size 75 x 75 x 75 cm (finished internal dimensions ) and 15 mm thick on internal wall surface finished even and smooth external using extra cement and plaster in cement mortar 1:4 and painted flush externally as posible and 50 mm thick PCC 1:2:4 type B-1 for copping and fixing new angle iron frame 40 mm x 40 mm x 6 mm with 4 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil including demolation of damaged existing valve pit complete all as specified and directed by Engr-in-Charge
Material & labour for construciton of brick masonry valve pit of size (105 x 105 x 105cm (finished internal dimensions ) using sub class "B" brick masonry in cement mortar cm 1:4 including plastering internally and painted flush externally as the work proceeds and PCC 1:2:4 type B-1 as in copping with angle iron frame 40 mm x 40 mm x 6 mm with 2 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil to distance n.exc 50 m including demolation of old damaged valve pit complete all as specified and directed by Engr-in-Charge
Repair to broken brick masonry valve pit of approx size 0.75 x 0.75 x 0.75 mtr to 1.1 x 1.1 x 1.1 mtr and remove the old plaster and usingmortor for plaster in cement mortar internally and painter flush externally as posible and PCC 1:2:4 type B-1 for copping and providing new MS sheet 4 mm thick cover of suitable size made of angle iron frame 40 mm x 40 mm x 6 mm with 4 mm thick MS sheet cover two side open with 2 Nos hinges each side and 2 Nos lifting handle and in built locking arrangement including lock and key and surface with two coats of synthetic black paint and a coats of red oxide paint on steel surface including necessary excavation in any type of soil, earth work in any type of soil all as specified and directed by Engr-in-Charge
Material & labour or repair and replacement of rusted /broken rubber packing both side of non return valve, ISI Marked, of CI body 80/ 100/150 mm bore Opening both side flanged with rubber packing including nuts bolts and wahsers etc complete as directed by Engr-in-Charge
Material & labour for Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of Capacity 0.10 to 0.50 lakh ltr water at pump house after draining out the water scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Material & labour for Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of Capacity 01 lakh ltr water at pump house after draining out the water scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Material & labour for Cleaning and painting external surface with cement based paint complete, colour as existing Semi under ground RCC sump of Capacity 1.5 to 3.15 lakh ltr water at pump house after draining out the water scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Material & labour for Cleaning and painting external surface with cement based paint complete, colour as existing overhead RCC tank at the top of the building up to G+15 of Capacity 10000 to 30000 ltr water after draining out the water scraping out bottom and side of wall with wire brush and bleaching powder, removing scaling fungus, flushing thoroughly with clean water, applying on coat of white washing after drying inside, writing of tank capacity and date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface all as directed by Engr-in-Charge
Dismantling and taking down old unserviceable power contractor of any make and supply and fix 3 pole power contaractor ML-4 suitable for motor upto 40 HP complete all as specified and directed.
Dismantling and taking down old unserviceable power contractor of any make and supply and fix 3 pole power contaractor ML 6 suitable for motor upto 40 to 70 HP complete all as specified and directed.
Dismantling and taking down old unserviceable power contractor of any make and supply and fix 3 pole power contaractor MNX 80 suitable for motor upto 60 HP complete all as specified and directed.
Dismantling and taking down old unserviceable power contractor of any make and supply and fix 3 pole power contaractor MNX type suitable for motor upto 40 HP complete all as specified and directed.
Material & labour for Cleaning of overhead PVC tanks of capacity 500 to 2000 ltrs in existing position by mechanised pressure cleaned by Mechanical high pressure spray and steel wire brush to remove algae/dirt/foregin completely and soaking out water/dirt with a high pressure wet vaccume pump and removing spoils outside of MD land and providing sticker showing the date of cleaning complete all as specified and directed by Engineer-in-Charge
Material & labour for Cleaning of overhead PVC tanks of capacity 2000 to 5000 ltrs in existing position by mechanised pressure cleaned by Mechanical high pressure spray and steel wire brush to remove algae/dirt/foregin completely and soaking out water/dirt with a high pressure wet vaccume pump and removing spoils outside of MD land and providing sticker showing the date of cleaning complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable tanks any capacity supply and fixing rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including plumber work or any GI fitting included in the quoted rate at a height of bldg up to G+15 bldg complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable tanks any capacity supply and fixing rotational moulded polyethylene water storage tanks of 1000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including plumber work or any GI fitting included in the quoted rate at a height of bldg up to G+15 bldg complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable tanks any capacity supply and fixing rotational moulded polyethylene water storage tanks of 2000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including plumber work or any GI fitting included in the quoted rate at a height of bldg up to G+15 bldg complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable tanks any capacity supply and fixing rotational moulded polyethylene water storage tanks of 3000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including plumber work or any GI fitting included in the quoted rate at a height of bldg up to G+15 bldg complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable tanks any capacity supply and fixing rotational moulded polyethylene water storage tanks of 5000 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position including plumber work or any GI fitting included in the quoted rate at a height of bldg up to G+15 bldg complete all as specified and directed by Engineer-in-Charge.
Supply and fix plastic water tank top cover double lock of capacity of tank 500 Ltr to 2000Ltr design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.
Supply and fix plastic water tank top cover double lock of capacity of tank 2000 Ltr to 5000Ltr design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.
Material & labour for taking out existing foot valve of any size from underground tank and disconnecting from the suction pipe and cleaning the same if serviceable conditin then refixing in the same postion complete all as specified and directed by Engr in Charge.
Supply & fixing in replacement sluice valve, ISI Marked, flanged type with spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 80 mm dia complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of unserviceable with new sluice valve, ISI Marked, flanged type with brass spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 100 mm dia complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of unserviceable with new sluice valve, ISI Marked, flanged type with brass spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 150 mm dia complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of unserviceable with new sluice valve, ISI Marked, flanged type with brass spindle including rubber, packing materials, nut, bolts and washers with locking arrangement in such a way that the valve can be locked in its open position ISI marked on body conforming to IS-14846 PN-1.6 of size 200 mm dia complete all as specified and directed by Engr-in-charge.
Supply and fixing foot valve, ISI Marked, 50 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc including taking down old unserviceable foot valve complete all as specified and directed by Engr-in-Charge.
Supply and fixing foot valve, ISI Marked, 80 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc including taking down old unserviceable foot valve complete all as specified and directed by Engr-in-Charge.
Supply and fixing foot valve, ISI Marked, 100 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc including taking down old unserviceable foot valve complete all as specified and directed by Engr-in-Charge.
Supply and fixing foot valve, ISI Marked, 150 mm size PN-1.6 pressure rating including all joints with rubber or fibre board, bolts, nuts washers, etc including taking down old unserviceable foot valve complete all as specified and directed by Engr-in-Charge.
Supply and fixing of water level indicator one Nos of each semi under ground sump with all accessories i.e Angle iron of suitable size including wedlng work wire as required gauge, PVC cane/drum , moving roller , welding work etc and one coat of synthetic enamel black paint front / back side and written / marking level gauge with white /red paint with all necessary safety equipment, helmet, ladder, rope, safety belt etc provided by contractor , complete all as specified and directed by Engineer-in-charge.
Material & labour for Painting of CI/GI pipe line 40 mm to 150mm inside the pump house and out side each pump house and all sluice valve, NRV gate valve) with one coat of synthetic enamel black/gray paint of existing colour shade with spray gun machine and after cleaning and preparation of surfaces complete all as specified & directed by Engr-in-Charge
Taking down the broken iron coupling from 60 HP to 75 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts as per sample complete all as specified and directed by Engr in Charge.
Taking down the broken iron coupling from 40 HP to 60 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts as per sample complete all as specified and directed by Engr in Charge.
Taking down the broken iron coupling from 5 HP to 30 HP motor / pump and fixing the new coupling with cotter pin, rubber piece and nut bolts as per sample complete all as specified and directed by Engr in Charge.
Taking down the broken rubber coupling from the 60 HP to 75 HP motor / pump and supply and fixing the new coupling with rubber piece and nut bolts complete all as specified and directed by Engr in Charge.
Taking down the broken rubber coupling from the 40 HP to 60 HP motor / pump and supply and fixing the new coupling with rubber piece and nut bolts complete all as specified and directed by Engr in Charge.
Taking down the broken rubber coupling from the 5 HP to 30 HP motor / pump and supply and fixing the new coupling with rubber piece and nut bolts complete all as specified and directed by Engr in Charge.
Supply & fixing in replacement non return valve, ISI Marked, of CI body 80 mm to 100 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement non return valve, ISI Marked, of CI body 150 mm to 200 mm bore flanged with rubber packing including nuts bolts and wahsers etc complete all as specified and directed by Engr-in-charge.
Taking out Old rusted and broken Fresh water tank lid and supply and fix in replacement of cast iron lid including locking arrangements black paint in /out side fixed on RCC water tank on top of building cap of tank 20000 gallons capacity
Material & labour for disconnecting the unserviceable pump set of capacity 60 to 75 HP any make from the pump foundation after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gasket, and replacene the unserviceable parts , gland packing, greasing, transporting back to pump house and refixing on the existing foundation, connecting the electrilc connection to the motror and testing complete to entire satisfaction of Engineer-in-Charge.
All as per srl item No 46.00 here in before but pump of capacity 40 HP
All as per srl item No 46.00 here in before but pump of capacity 30 HP
All as per srl item No 46.00 here in before but pump of capacity 10/15 HP
All as per srl item No 46.00 here in before but pump of capacity 5/7.5 HP
All as per srl item No 46.00 here in before but pump of capacity 2 to 3 HP
Material and labour for rewinding the electric motor of capacituy 60HP to 75 HP capacity, disconnecting the electtic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to workshop (Note:- following workds deemed to be included in the quoted rates.) (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing and paper removal all carbons. (c) Insert insulating materials such as insulating paper sleeves. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load and complete all as specified and directed by Engr-in-charge.
All as per srl item No. 52.00 here in before but Motor of capacity 40 HP
All as per srl item No. 52.00 here in before but Motor of capacity 30 HP
All as per srl item No. 52.00 here in before but Motor of capacity 10/15 HP
All as per srl item No. 52.00 here in before but Motor of capacity 5/7.5 HP
All as per srl item No. 52.00 here in before but Motor of capacity 2/3 HP
All as per srl item No. 52.00 here in before but Motor of capacity 0.5/1.5 HP
Material & labour for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 40 HP to 75 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and errction the pump and motor testing to the entire satisfaction of Engineer-in-Charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including Concrete required for foundation
Material & labour for dismantling the rusted foundation bed of the motor and pump set, and fabrication of the forundation beds with MS channels angle of the required as per pump set capacity( 20 HP to 40 HP) and duly applying one coat of red oxide primer and two coat of bitumen paint of approved quality and errction the pump and motor testing to the entire satisfaction of complete all as specified and directed by Engr-in-charge. Note:- (a) However quoted rate is deemed to be included for welding work, nuts, bolts, washer and MS fasteners including concrete required for foundation
Supply, fixing and testing water meter suitable to fit in 80/100/150mm bore in existing GI/CI pipe complete with flange, gasket, nuts, bolts and all necessary required items all as specified and directed by Engineer-in-Charge.
Repair/Maintenance to Chlorine dozing system assembly with chlorine injector dozing pump, cleaning, servicing, carrying out minor repairs and testing. (Note : (a) Work is including consumables like cotton waste cloth etc. (b) Parts and spares requied to be replaced.
Supply & fixing in replacement of dosing Pump high pressure single head gear motored adjustable dosing pump with accessories include lead tubing, connecting nuts, injection check valve, clay weight, ferules etc complete all as specifed and directed by Engr in Charge.
Supply and Fixing in replacement of dosing system consisting 40 ltr-100 ltr PE/FRP Tank with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank complete all as specified and directed by Engr in Charge.
Supply only Calcium Hypochlorite in granular form in 45 Kg drum, having minimum 70% of available chlorine (Ca(OCI)) with anti-corrosive and anti-scaling properties suitable for human consumption. Note: Contractor shall produce letter of authorisation, COA with unique serial number and NSF certiifcate from manufactuer.
Disconnecting all electric connections from the chlorine dosizing motor 1.5 HP & taking out and rewinding the same motor with copper winding and refixing the same postion and testing complete all as specified and directed by Engr in Charge.
Supply and fix in repair of new butterfly valve, ISI Marked, of PN 1.0 of dia 80mm complete all as specified and directed by Engr-in-charge.
Supply and fix in repair of new butterfly valve, ISI Marked, of PN 1.0 of dia 100mm complete all as specified and directed by Engr in Charge.
Supply and fix in repair of new butterfly valve, ISI Marked, of PN 1.0 of dia 150mm complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair 40 mm of gun metal globe or gate valves, ISI Marked, with iron whel head, screwed both endes for iron pipe complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair 50mm of gun metal globe or gate valves, ISI Marked, with iron whel head, screwed both endes for iron pipe complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement 80 mm of gun metal globe or gate valves, ISI Marked, with iron whel head, screwed both endes for iron pipe complete all as specified and directed by Engr in Charge.
Material & labour for disconnecting all electric connections from the submersible pump & motor 03 HP and taking out column assly from bore well and transporting the same to civil workshop for repair including winding etc complete all as specified and directed by Engr-in-charge.
Disconnect the electric connections form starter and taking out burnt submersible starter from the existing position and supply and fixing new water sensor, starter 3 phase of 10HP , 440 Volt , front side openable and locking arrangement complete all as specified and directed by Engr-in-charge.
Water testing report of BASIC TEST / HEAVY METAL TEST /PATHOGENS TEST as per list . Collection of empty sterlised bottles from the Govt/ authorised lab Mumbai , Maharashtra after taking out water sample from user end / pump house. Water sample filled bottle depositing to the same lab for anaylsis test and collect the sample report and deposited to E/M sub divn complete all as specified and directed by Engr-in-charge. Location : Reviera/ INS Shikra/ NT Pool/ Sasson Complex/ Bhagirathi/ Aditi/ Vishakha/Vandana/Foma hous pump house
Material & labour for attending leakage complaints in pump house/ high rise building by checking centrifugal pump / NRV / sluice valve/Non return valve/gate valve of pipe line leakage including replacement of unseriviceable component including preventive maintinance spares by replacing minor parts i.e galand packing nut and bolts complete all as specified and as directed. Note :- If the contractor will not attend the complaints by his trades man in any working day /holiday including sunday the necessary reovery of Rs. 500/- per day shall be imposed complete all as specified and directed by Engr in Charge
Material & labour for attending underground pipe line leakage complaints of pipe of dia 80 mm to 150 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate.
Material & labour for attending underground pipe line leakage complaints of pipe of dia 20 mm to 63 mm upto 2 mtr depth line in any type of soil/ hard standing/ under road including earth work/welding work and labour charges complete all as specified and directed by Engr in Charge. Note : any pipe/ pipe fittings/rubber packing/any type of joint required for stop the leakage up to 5 mtr length of pipe included in the same rate.
Taking out sluice valves of dia upto 250 mm and refacing, regrinding and repair the same and refixing in same position complete all as specified and directed by Engr-in-charge.
Supply, fix, install, testing and commissioning of Power factor Panel, outdoor type cubical shape, made out of CRCA sheet 3.15 mm thick, factory fabricated, CPRI approved, powder coated, dust and vermin proof, provn for ventilation, angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly and accommodate the items mentioned below. Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 40 KVAR and cylindercal type MD-XL capacitor bank of capacity 40 KVAR with APFC relay adjustable thermal magnetic release MCCB 63 Amps 3 pole breaking capacity 16 KA. and air circulating fan for cooling including all accessories complete all as specified and directed by Engr-in-charge.
Supply, fix, install, testing and commissioning of Power factor Panel, outdoor type cubical shape, made out of CRCA sheet 3.15 mm thick, factory fabricated, CPRI approved, powder coated, dust and vermin proof, provn for ventilation, angle iron frame and four legs of 50x50x6mm thick angle iron ,1 ft long grouted on PCC foundation of height not less than 40 cm from the ground level , grouting properly and accommodate the items mentioned below. Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 60 KVAR and cylindercal type MD-XL capacitor bank of capacity 100 KVAR with APFC relay adjustable thermal magnetic release MCCB 160 Amps 3 pole breaking capacity 25 KA. and air circulating fan for cooling including all accessories complete all as specified and directed by Engr-in-charge.
Taking down of leakage /rusted not grether than of 3 mtrs 100 GI suction pipe from the existing position pump house and replace with new GI pipe line of size 100 mm by threading / welding work / bend /, flanged / , nut, bolts /, labour charge complete all as specified and directed by Engr-in-charge.
Supply and laying GI tubing 15 mm dia medium grade with all fitting such as tee, socket, bend, union etc in wall/trenches including taking down old rusted pipe complete all as specified and directed by Engr in Charge.
All as per srl item No 84.00 here in before but 20 mm dia
All as per srl item No 84.00 here in before but 40 mm dia
All as per srl item No 84.00 here in before but 50 mm dia
All as per srl item No 84.00 here in before but 80 mm dia
All as per srl item No 84.00 here in before but 100 mm dia
All as per srl item No 84.00 here in before but 150 mm dia
Material & labour for in repair maintenance free chemical earthing of environment friendly earth electrod set comprising of 17.2 mm dia , 3 m long rod low carbon steel molecular copper bounded for a thickness of 250 micro Omhs highly conductive ANS/INSF STD -60 certified carbon bound backfill compound which shall set like concrete accordingly to BS 7430 & IEEE 80 each bag shall contain 50 ibs complete all as specified and directed by Engr-in-charge.
Material & labour for Welding work any type Gas welding/ electric welding for any tpye of Job complete all as specified and directed by Engr-in-charge.
Supply and fixing bronze impeller suitable for 60/75 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as specified and directed by Engr-in-charge.
Supply and fixing bronze impeller suitable for 40 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as specified and directed by Engr-in-charge.
Supply and fixing bronze impeller suitable for 20 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 630 Amps, 36kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 400 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 200 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,4Pole, 160 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 200 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Dismantling of Damaged/Burnt MCCB and Supply & fixing of MCCB,3 Pole, 160 Amps, 25kA, 415Volts,50Hz AC s complete all as specified and directed by Engr-in-charge.
Supply and laying MS pipe 100 mm dia in wall/ trenches alongwith all fittings such as tee,bend, socket, etc complete all as specified and directed by Engr in Charge.
Material & labour for area cleaning of water supply including clearing of veglitation, wild growth and trimming of grass etc in and around the water storage tanks, valve pits and installation compound and removing rubbish off the premises complete including spreading of suitable chemicals as approved for further growth of weeds and vegtation in the vicinity of installations complete all as specified and as directed.
Material & labour for PTMT float valve, ISI marked, 15 mm dia high pressure with polythene float and fly complete, screwed for Aluminium rode or PVC fenle and fixed in all as specified and directed .
Material & labour for PTMT float valve, ISI marked, 20 mm dia high pressure with polythene float and fly complete, screwed for Aluminium rode or PVC fenle and fixed in all as specified and directed .
P LAXMI AND CO. (BID ID -3093088)
SHRI SAI ENTERPRISES (BID ID -3076079)
shubham construction (BID ID -3086874)
Chakshu Enterprise (BID ID -3097687)
Shree Ayyappa Engineering (BID ID -3093073)
Idustrial products India (BID ID -3093129)
Nexus Infratech (BID ID -3093091)
SHREE JAGDISH FURNITURE CO. (BID ID -3076024)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .