Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Due to lowest | |
| 2 | L2₹35.4 L+₹9,080.50 (0.26%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹37.9 L+₹2.6 L (7.31%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹38.5 L+₹3.1 L (8.90%)Rejected-Finance N A | NA | NA | 121004 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46.4 L
EMD Value
₹92,800
Closing Date
26 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bikaner
GE North Bikaner
PROVN OF SPL REPAIRS TO BLDG NO P05 JCOS LIVING AND PROVN OF SPL REPAIR TO BLDG NO T197 200 OR LIVING BKS AT MIL STN BIKANER
2022_MES_508915_2
GE (N) BKN TOKEN NO 77 /2021-2022
Open Tender
Civil Works
Item Rate
270 days
BIKANER
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹92,800
Yes
3 Jun 2022
11 Mar 2022
28 Mar 2022
11 Mar 2022
26 Mar 2022
12 Mar 2022
60 days
Amount
Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed by Engineer-in-Charge.
Demolition Concrete of any description and in any position not otherwise specifically provided for incl clean the surface . (utmost care has to be taken while demolishing pcc padding as in roof treatment ) complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete incl(sand stone/ tiling/Kota stone) in floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-Charge.
Dismantling Stone slabs of any description or thickness in roof ,sun shades, floors, aprons etc laid and pointed in any mortar. (Note: Dismantling shall be carried out in portion only .) complete all as specified and as directed by Engineer-in-Charge.
Raking out to stone slab as in roof stone patti or precast concrete slab floor, any description, laid flat complete all as specified and as directed by Engineer-in-Charge.
Demolition of lime concrete of any description over roof slab complete all as specified and as directed by Engineer-in-Charge.
Taking up or down steel tubing 15 mm bore with connections for cleaning for refixing or removing to store yard complete all as specified and as directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc. 1.50sqm each but with shutter (w/o taking of shutter from the frame ) complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames exc. 1.50sqm each but nexc 4.00 Sqm with shutter (w/o taking of shutter from the frame ) complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any desc exc 1 sq. m but n exc 2 sq.m each and refixing in the same opening after necessary easing adjustment etc complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames not exc. 1.50sqm each but with shutter (w/o taking of shutter from the frame ) form archives , soffits , linings, window boarding etc. and refixings in other openings complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames exc. 1.50sqm each but nexc 4.00 Sqm with with shutter (w/o taking of shutter from the frame ) form archives , soffits , linings, window boarding etc. and refixings in other openings complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any desc exc 1 sq. m but n exc 2 sq.m each complete all as specified and as directed by Engineer-in-Charge.
M&L Jodhpur stone of roof slabs, self faced 7.5 cm to 10cm thick, 25cm to 35cm wide, hoisted and set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L Rough dressed sand stone slab 20 to 25 mm as in chajja but jointed and pointed in cement mortar 1:3 complete all as specified and as directed by Engineer-in-Charge.
M&L Jodhpur stone for lintels, beams and roofs, self faced, 7.5 to 10cm thick complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks, old sized ,straight or curved on plan exc 6 m mean radius, built in ement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with flyash bricks, old sized straight or curved on plan to any radius in half brick thick walls built in 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with sub class B bricks , old sized built in cement mortar 1:4 (curved to plan with mean radius n. exc. 6m with bricks) roughly cut to radius or bricks with wedge shaped joints complete all as specified and as directed by Engineer - in charge.
M&L for Rendering 15mm thick cement plaster on fair faces of brick or conc. Surfaces in cement mortar 1:6,even and smooth w/o using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for 20 mm thick Rendering on walls of stne masonary or other than fair faces of brick work of Heritage construction in cement mortar 1: 4 on concrete surfaces, finished Fair & even including mixing water proofing compound as per manufacturer's instns( WPC to be measured separately as supply only)
M&L for flush pointing in cement motor 1:4 over stone patti in paving etc complete all as specified and as directed by Engineer-in-Charge.
M&L for pcc type B1 , 1:2:4) using 20 mm graded agg as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed , incl all necessary form work etc complete all as specified and as directed by Engineer-in-Charge.
M&L for TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L for TMT bars 5 mm to 10 mm dia in reinforcement as in stirrups, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L for Chattri Rajasthani Herritage pattern 600x600x900 mmof cement concrete with and including stone concrete as approved and directed by Engg-in-charge
M&L Rajasthani Herritage pattren water drain 750 mm long of Dholpur stone as approved complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 110mm bore single socketed , in any length with rubber ring joints fixed to wall incl GI clamp duly fitted with Rubber gasket Holding bolt screwed threaded rod as space adjuster ,incl taking down of existing AC rain water pipes complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) bend any radius for 110mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
M&L for repair to existing chattri incl all necessary moulds dismantlig errection and other necessary works matrerial included complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by Engineer-in-Charge.
M&L for priming surfaces with bituminous primer conforming to IS-3384 @ 0.30kg/sqm, after drying of primer applying a coat of hot blown bitumen conforming to IS-702 @ 1.20 kg/sqm and layin polymeric water proofing membrane, five layerd with centre core of 90 micron high molecular density polythelene film (min weight 3kg per sqm) with end over laps not less than 150mm and side lap 75 mm and applying a coat of semi hot blown bitumen 85/25 grade @ 0.50kg/sqm and dusted over the bitumen coat complete all as specified and as directed by Engineer-in-Charge.
M&L Lime concrete terracing as specified on roof in portions complete all as specified and as directed by Engineer-in-Charge.
M&L Roughing surfaces of old conc surfaces by picking up , sweeping,cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @3kg/Sqm mixed with water proofing compound(WPC shall be measured and paid separatley) complete all as specified and as directed by Engineer-in-Charge.
M&L Cement concrete 50 mm thick type B-1, 1:2:4 (20 mm graded aggregate) as in bedding layer/ levelling course or protection to roof treatment laid in pannels and Forming Contraction (Dummy) joints 30mm deep x 10mm wide, filled with sealing compound complete all as specified and directed by Engr-in-Charge
M&L Cement concrete 25 mm thick type B-0, 1:2:4 (12.5mm graded aggregate) as in bedding layer/ levelling course complete all as specified and as directed by Engineer-in-Charge.
M&L Granite20 mm th (of any type) work (table rubbed and polished) in shelves ,steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engineer-in-Charge.
M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and as directed by Engineer-in-Charge.
M&L Mild steel framed work such as grills ,framed guard bars barred iron doors ;ladders framed balusters railings and similar work conforming to Fe 410-0or Fe 310-0 complete all as specified and as directed by Engineer-in-Charge.
M&L Mild steel Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe410, Gde E 250 complete all as specified and as directed by Engineer-in-Charge.
M&L 20-25 mm thick single piece machine cut kota stone slab as in flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing 15 mm thick screed bade in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.( Note: Kota Stone shall be of one lot and all sides must be perpendicular to each other)
M&L for 100mm wide strip of makrana white marble 14-16mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing types. all as specified.
M&L 15 mm thick machine cut kota stone slab on vertical surfaces as in skirting/riser etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing, over and also making edges rounded or bull nosed, over and including and including 10 mm thick rendering in cement and sand mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Cutting to existing kota stone/dholpur flooring including minor repairs and polishing upto mirror finish complete all as specified and as directed by Engineer-in-Charge.
M&L 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed by Engineer-in-Charge.
M&L for 2nd class hard wood for Transoms or mullions, straight, for solid frames of any description, wrought, framed, double rebated on the solid, rounded or chamfered (including weathering to transom, if required put together with glue, pinned at joints), supplied and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F 35mm thick IInd clas hard wood wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of wooden panneles: supplied and fitted to chowkats complete all as specified and as directed by Engineer-in-Charge.
M&L for IInd class hard wood wood 30mm glazed and skelton shutter open rebated and prepared to receive glass,gauge et for windows , ventilators .(w/o sash bars)edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc.as spcd. Clause 8.20(a) complete all as specified and as directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and avg width of aperture1.18mm complete all as specified and as directed by Engineer-in-Charge.
S&F But hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, 100mm complete all as specified and as directed by Engineer-in-Charge.
S&F But hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, 75 mm complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm Long Brass handles with and including brass screws old tradational pattern complete all as specified and as directed by Engineer-in-Charge.
S&F 100 mm dia Brass handles ornamental pattern with and including mounting plate screws etc complete all as specified and as directed by Engineer-in-Charge.
S&F 200 mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts with barrel of extruded section complete all as specified and as directed by Engineer-in-Charge.
Ditto all as per item no 56 above but 100 mm
S&F 300 mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts and fixed complete all as specified and as directed by Engineer-in-Charge.
M&L for corboling stone for supporting chajja as directed by engineer in charge
M&L for sheet glass 4mm thick ordinary quality and glazing with oil putty / nails/ wooden beads in square not exc.0.5 Sqm in each pane as reqd at site complete all as specified and as directed by Engineer-in-Charge.
M & L 15 mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs bib taps cast copper alloy chromium plated fancy type 15mm bore with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
M&L for Preparing old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge.
M&L for applying two coats of white washing on ceiling including preparation of new/old plastered surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L One coat fo white wash on old ceiling complete all as specified and as directed by Engineer-in-Charge.
M&L for preparing new/old plastered or plasteed surface applying two coat of cement base paint (Terra cotta red ) (Ist quality) in plain pattern on walls and over a coat of alkali resistant priming paint complete all as specified and as directed by Engineer-in-Charge.
M&L Complete removal of synthetic paint on old wooden surfaces with paint remover chemical and appllying wood filler duly sanding , with Lacquer shellac varnishing under coating of Varnish and finishing coat with mellamine spray and sizing on new wooden surfaces or old paint removed surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by Engineer-in-Charge.
M&L for providing and injecting chemical emulsion for Post constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.50 ltr per sqm of the vertical surface of the sub structure to a depth of 300 mm including excavated channel along the wall and rodding etc complete. (Note: The treatment work shall be carried through authorised agencey only , and certificate for the same for warranty shall have to frunished before submitting payment) complete all as specified and as directed by Engineer-in-Charge.
M&L for providing and injecting Along the external wall below concrete or masonry apron using Antitermite Treatment chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.(Note: The treatment work shall be carried through authorised agencey only , and certificate for the same for warranty shall have to frunished before submitting payment)
M&L for providing and injecting Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors .(Note: The treatment work shall be carried through authorised agencey only , and certificate for the same for warranty shall have to frunished before submitting payment)
M&L for providing and injecting Of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes.(Note: The treatment work shall be carried through authorised agencey only , and certificate for the same for warranty shall have to frunished before submitting payment) . and drilling holes at45 degree and plugging the same with cement mortar 1:2 to match with existing surface complete all as specified and as directed by Engineer-in-Charge.
M&L for providing at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same .(Note: The treatment work shall be carried through authorised agencey only , and certificate for the same for warranty shall have to frunished before submitting payment) complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing false ceiling of ac sheet etc complete all as specified and as directed by Engineer-in-Charge.
Dismantling Asbestos cement Corrugated sheets in roof covering including ridges complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L for pre painted galvalume aluminium zinc cozting GI based corrugated steel Sheet high rib profile tile pattern color coated 0.5 mm thick of 550 Mpa Tensile strength sheets as in roof covering and fixed as per manufacturers instruction (design as app by Engg in charge complete all as spfd )
M&L Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
M&L for 10mm thick rendering on brick or concrete surfaces in cm 1:6 finished even and smooth w/o using extra cement complete all as specified and as directed by Engineer-in-Charge.
S&F Composite cement ceiling board 4 mm thick in ( 595 mmX595 mm ) pannel (Make-everest ramco or eql.) designer ceiling pre finished conforming to IS 14862 type B cateogory three incl GI frame , grid work,hold fast,suspended with suspender along with holding down bolt complete . (Note: Ceiling board shall confirming to IS-14862 ,shall be fire resistant , Moisture resistant and ceiling shall be suspended with suspenter and adjuster .) complete all as specified and as directed by Engineer-in-Charge.
M&L PCC 1:3:6 type C-2 20 mm graded stone aggregate as in foundations, filling and mass concrete , sub base complete all as spfd and as directed by engineer in charge
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair complete all as specified.
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
M&L Jodhpur stone of roof slabs, self faced 5.00 cm thick, as in shelves , chajjas shelves etc nexc 2 m in length., hoisted and set, jointed and grouted in lime mortar 1:3 or cement mortar 1:6 complete
M&L mild steel rolled section / tubular section as in main and cross beams purlins, rafters, posts where connected to common rafter and running rails etc conformi ng to FE-410-W complete all as specified and as directed by Engineer-in-Charge.
S&F 125 x 60mm mild steel pressed steel frames for doors with one or more rebate including necessary fixing lugs, hinges lock strike plate etc complete as specified including a coat of shop coat zinc chrome primer complete all as specified and as directed by Engineer-in-Charge.
S&F 35mm thick Factorymade second class hard wood plain framed pannelled shutter (two panels and double shutter) with lock rail and pannel or 9mm BWP comerical ply or 12mm venered particle board with comerical face venering on both faces. The size of rail and style as per IS-1003 part kilin seasoned complete all as specified and as directed by Engineer-in-Charge.
S&F 2nd class hardwood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass guage, etc. (without sash bars), edges of framing plain, chamfered or rounded. Fitted with cut and mitred beads for securing glass,etc. sizes of members of shutters as specified in SSR Part I, section 8, clause 8.24(a); supplied and fitted to chowkhats complete all as specified and as directed by Engineer-in-charge.
S&F mild steel barrel tower bolt, stove enamelled black with bright bolt of 150 mm complete all as specified and as directed by Engineer-in-Charge.
S&F mild steel sliding door bolts plate type stove enameled black with bright bolt not less than 12 mm dia with and incl. a minimum of 6 bolts and nuts four on bolt plate and two on staple plate of 300 mm long complete all as specified and as directed by Engineer-In-Charge.
S&F MS pressed handle oval type stove enamel block with bright bolt of 150 mm. complete all as specified and as directed by Engineer-in-Charge.
S&F brass 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by engineer-in-charge.
S&F in replacement curtain rod 20mm dia, mild steel, chromium plated, fancy type with fixing brackets and knobs at both ends as per site requirement complete all as specified and directed by Engr-in-Charge Note :- The cost of brackets and knobs is deemed to be incl in the quoted rate. Nothinbg extra shall be paid on this account complete all as specified and as directed by Engineer-in-Charge.
S&F factory made mild steel Window box type with side huge shutters incl pintol hinges,steel handles, steel peg stay and all locking arrangement and one shop coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. Note : i) The window shall be fabricated as per Drg No CEBTZ/TD/888R & 889 ii) MS fillets, glazing, wire gauge shall be measured and paid separately iii) opening incl provn shutter for cooler to be provided
M&L for prep of new plastered and unplastered surfaces of walls by applying a 3 mm thick thin layer of Birla white putty to give uniform surface applying coat of oil bound distamper on walls old decorated surfaces of desired finish complete all as specified and as directed by Engineer-in-Charge.
M&L Complete removal of existing treatment of walls and applying two coats of oil bound distemper over a thin coat of wall care putty complete all as specified and as directed by Engineer-in-Charge.
M&L Complete removal of existing treatment of walls and applying two coats of cement based paint complete all as specified and as directed by Engineer-in-Charge.
M & L for Screed bed or bedding layer of mortar(1:6) 15mm thick for laying floor finishes complete all as specified and directed.
M&L Chequered cement concrete tiles 20cmx20cmx25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment complete all as specified and as directed by Engineer-in-Charge.
M&L hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layer n exc. 15 cm thick watered and rammed to a true surface complete all as specified and as directed by Engineer-in-Charge.
M&L for 75mm thick PCC (1:4:8), type C2 using 40mm graded stone agg as in sub base of floors etc finished even and rough complete all as specified and as directed by Engineer-in-Charge.
M&L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade to IS 15658-2006 manufactured using grey cement and no pigment complete all as specified and as directed by Engineer-in-Charge.
M&L for 25 mm thick sand filling under floors, cushning under interlocking tiles or in foundations complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D2, using 40mm graded stone agg as in mass filling and fdn complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and as directed by Engineer-in-Charge.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed by Engineer-in-Charge.
Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge for the following :- (a) One Light/fan/ex-fan/Bell/point controlled by one switch.
(b) One pin 5 amps socket point on the same board with other switches complete
(c) One 3 pin 5 amps socket on independent board.
Ditto all as per item No 111 above but with 2.5 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
Ditto all as per item No 111 above but with 4.0 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
S&F switch piano type, 5 Amp, single pole one way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
M&L Switch piano flush type single pole, one way 15 Amps 230 Volts complete all as specified & directed by Engr-in-Charge.
M&L socket outlet 3Pin, 5 Amps flush type 230 Volts complete all as specified and directed by Engr-in-Charge.
M&L for socket outlet 2 in 1, 3 Pin, 5 & 15 Amps, 230 Volts tcomplete all as specified & directed by Engr-in-Charge.
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified and as directed by Engineer-in-Charge.
supply and fixing fan regulator electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
S&F LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Philips-BN021 LED 20S PSU CW GR S2/ Crompton Greaves LDDR20-CDL Dazzle Ray / bajaj-BCLAB 20W
M & L white metal shade study lamp white base complete with LED bulb 7 watt complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure MCB DB, double door, TPN 4 way with 200 Amps rated busbar complete all as specified and as directed by Engineer-in-Charge. Make:- Hegar/Legrand/Seimens
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S&F MCCB 100 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
S&F MCB 63amps, C curve TPN, 415 volts, complete all as specified and as directed by Engr-in-charge.
S & F MCB DP,D CURVE 40 Amps , 240 volts, complete all as specified and as dircted by Engr-in-charge.
M&L for submain wiring using 2 runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 2runs of 6 Sqmm of voltage rating 1100V for Single phase & neutral, drawn in and including concealed PVC conduit of dia not less than 25 mm dia with standard acessories, along with two run of FRLS PVC insulated, unsheathed, stranded copper conductor of size 2x 6.0 Sqmm as earth continuity conductor all as specified and directed(Note-2 runs of single core FRLS PVC cable 6sqmm for Single phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit) complete all as specified and as directed by Engineer-in-Charge.
M&L for submain wiring using 4 runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4runs of 10 Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including concealed PVC conduit of dia not less than 25 mm dia with standard acessories, along with two run of FRLS PVC insulated, unsheathed, stranded copper conductor of size 2x 6.0 Sqmm as earth continuity conductor all as specified and directed(Note-4 runs of single core FRLS PVC cable 10sqmm for three phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as directed by Engineer-In-Charge.
Taking down fan,sealing cable end,dismantling blades and removing fan and blades & refixing ceiling fan of any make, any sweep , keeping side in store in safe custody for painting of ceiling fan complete,in situ with synthetic enamel paint by spraying including filling cavities with filler,one coat after cleaning all dust and reassembling the fan complete including writing MES No at the site complete all as specified and as directed by Engineer-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion complete all as specified and as directed by Engineer-in-Charge.
S&F GI tubing light grade 40mm dia for protection of cable on pole/ wall etc complete all as specified and as directed by Engr in charge.
S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED bulb 12Watt Minium 3star rated voltage 220-240,50Hz ,rated lumen 954im,pf-.90 complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m width for laying of cable lines etc and getting out in hard/ dense soil complete all as specified and as directed by Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge.
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness complete all as specified and as directed by Engineer-in-Charge.
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry flat across length of the cable with width of the trenches equal to length of bricks complete all as specified and as directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sq mm 4 core complete all as specified and as directed by Engineer-in-Charge.
Beenu Co. Company
GS BUILDERS AND ENGINEERS
N.K. CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .