Tender Value
₹3.8 L
EMD Value
₹4,000
Closing Date
1 Sept 2023, 4:00 pmClosed
SE EDC-I RAEBARELI
SE EDC-I RAEBARELI
WORK MENTION IN BOQ
2023_MVVNL_832123_1
113/EDC-I,R/2023-24
Open Tender
Electrical Works
Item Wise
30 days
UNDER EDD-I RAEBARELI
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
EX ENGINEER C AND MC RAEBARELI
₹4,000
13 Sept 2023
26 Aug 2023
2 Sept 2023
26 Aug 2023
1 Sept 2023
26 Aug 2023
Amount
CARTAGE OF FOLLOWING STORE ITEMS FORM ESC, RAEBARELI TO DUMP SITE AND DUMP SITE TO WORK SITE ALONG WITH LOADING, UN-LOADING AND PROPER STACKING
11 Mtr long ST Poles
loose line material including
ACSR DOG CONDUCTOR 200Mtr, AB CABLE 3X120+1X95+1X16 SQ MM 800 Mtr.
(B) ERRECTION
Errection of 11Mtr. Long ST Pole including digging of Pits & fitting of accessories.
Errection of Double pole by ST Pole including digging of Pits & fitting of accessories.
Earthing of poles as per RESSPO norms.
Digging of pits, fixing nozzling & grouting of stay rods as per RESSPO norms including grouting materials.
Laying, stringing & sagging of 3Ø 3 wire 11 kv HT line by ACSR Dog conductor including all associated works & making clearance of road with joints/jumpers & binding on insulators as required.
Construction of plinth of Size 2.5X2.5X2 Mtr. for mounting of 250KVA & 400KVA T/F complete in all respect as per norms required material will be provided by the contractor.
Shiffting of 2 No.Transformer From Digree College Chauraha to ROTARY CLUB and Mounting of 250 KVA & 400 KVA T/F on Plinth including all associated works as required.
Digging of 2x60 feet deep boring type for earthing neutral and body of distribution T/F at two places and welding of G.I strip including the cost of M.S. pipe 1.25 Inch dia, 2*40 feet long and MS strip 25*3 mm of suitable length for connecting M.S pipe to neutral through proper welding or bolt and nut. All material, consumables and T&P will be privided by contractor.
Construction of Henely type tailles fuse unit 300Amp. (Two Circuit) for 250KVA Distribution Transformer Sub-Station
Construction of massonary type Distribution pillar box with first class brick ballast cement couarse sand, local sand , bric ballast , and MS Round bar of 10mm dia including straight MS Angal 50X50X6X750 mm for 250 KVA LT Substation (All the material will be arranged by the contractor)
Fixing of Henley type tail less Fuse unit 300 Amp, 650 Volt consisting of 6 Nos Brass Back entry, 6 Nos U-type Spny contact made of Copper, Brass coupling with Porcelain fitted on the GI sheet of 16 SWG with arrangement of 1 Nos Neutral link alongwith Copper bus-bar of size 750X50X6 mm made of electric copper strip for 250 KVA Transformer and required size GI Nut, Bolt and Washer with proper connection of LT single core PVC Cable of required size (cable will be provided by the department) (GI Nut, Bolt and Washer Will be arrange by the contractor).
Fixing of Copper L-piece suitable for 250 KVA Transformer of size 125X75X50X6 mm made of electrolite Copper strip (99.9% Purity) with required size (240/400 Sq. mm) Alluminium Crimping Lugs (99.9% Pure A-grade Alluminium).
Repair & extension of existing wire mesh fencing around Transformer and Distribution Pillar Box with retaining Wall & 1 No. gate with locking arrangement made of MS Angle iron of size 50X50X6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50X6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESPO. (All the material will be arranged by the contractor).
Construction of Henely type tailles fuse unit 500Amp. (Two Circuit) for 400KVA Distribution Transformer Sub-Station
Construction of massonary type Distribution pillar box with first class brick ballast cement, couarse sand, local sand , bric ballast , and MS Round bar of 10mm dia including straight MS Angal 50X50X6X750 mm for 400 KVA LT Substation (All the material will be arranged by the contractor)
Fixing of Henley type less Fuse unit 500 Amp, 650 Volt consisting of 6 Nos Brass Back entry, 6 Nos U-type Spny contact made of Copper, Brass coupling with Porcelain fitted on the GI sheet of 16 SWG with arrangement of 1 Nos Neutral link alongwith Copper bus-bar of size 750X50X6 mm made of electric copper strip for 400 KVA Transformer and required size GI Nut, Bolt and Washer with proper connection of LT single core PVC Cable of required size (cable will be provided by the department) (GI Nut, Bolt and Washer Will be arrange by the contractor).
Fixing of Copper L-piece suitable for 400 KVA Transformer of size 125X75X50X6 mm made of electrolite Copper strip (99.9% Purity) with required size (240/400 Sq. mm) Alluminium Crimping Lugs (99.9% Pure A-grade Alluminium).
Repair & extension of existing wire mesh fencing around Transformer and Distribution Pillar Box with retaining Wall & 1 No. gate with locking arrangement made of MS Angle iron of size 50X50X6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50X6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESPO. (All the material will be arranged by the contractor).
Stringing and sagging of 2 wire of 6SWG G.I. Wire for guarding and making lacing at 1 meter a part in all the spans .
(C) Following Metarials to be supplied by contractor
LTMS CLAMP STP
M.S. HOLDING CLAMP
NUT BOLT OF SIZE
F BRACKET
STAY CLAMP STP
LUG 400/630 KVA
COPPER L PIECE
STAY INSULATOR
TAILLESS UNIT 500AMP 250/400KVA T/F
Siddhi Enterprises
M/S SUBHASH TRADERS
M/S Shiv Traders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .