Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
25 Sept 2026, 3:30 pm
Superintending Officer (EEACS), RRCAT
Office of SE (EEACS), RRCAT, Indore
Design, fabrication, supply, installation, testing and commissioning of HVAC system for RF Lab at RRCAT, Indore
2026_RRCAT_924481_1
RRCAT/EEACS/2026/25
Open Tender
Electrical Works
Works
510 days
RRCAT
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2.4 L
Yes
3 Sept 2026
3 Sept 2026
28 Sept 2026
3 Sept 2026
25 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Supply, installation, testing and commissioning of horizontal double skin PUF insulated recirculatory Air Handling Units (AHU)s in modular construction having thermal break profile complete with direct driven fan, electric motor, cooling coil, SS-304 eliminator, filters (pre & fine), mixing chamber and other associated accessories of following capacity as per tender technical specifications. a) Capacity : 42.5 TR
b) Air Flow Rate : 15000 CFM
c) St. Pressure : 100 mm of WC | 2 | Nos. | - | - |
| 2.01 | Supply, fabrication, installation, testing and commissioning of GI ducting fabricated out of following thickness sheets. The GI ducting shall be complete with bends, elbows, reducers/transition pieces, MS or GI flanged joints, 6 mm thick neoprene gasket, GI hardware, leak proof joints silicon sealant etc in accordance with IS-277,IS-655 as per tender drawings and technical specifications. 22 G thick GI sheet ducting | 60 | Sq.mtr. | - | - |
| 2.02 | Supply, fabrication, installation, testing and commissioning of GI ducting fabricated out of following thickness sheets. The GI ducting shall be complete with bends, elbows, reducers/transition pieces, MS or GI flanged joints, 6 mm thick neoprene gasket, GI hardware, leak proof joints silicon sealant etc in accordance with IS-277,IS-655 as per tender drawings and technical specifications. 20 G thick GI sheet ducting | 250 | Sq.mtr. | - | - |
| 2.03 | Supply, fabrication, installation, testing and commissioning of GI ducting fabricated out of following thickness sheets. The GI ducting shall be complete with bends, elbows, reducers/transition pieces, MS or GI flanged joints, 6 mm thick neoprene gasket, GI hardware, leak proof joints silicon sealant etc in accordance with IS-277,IS-655 as per tender drawings and technical specifications. 18 G thick GI sheet ducting | 110 | Sq.mtr. | - | - |
| 3 | Supply and installation of 16 mm thick closed cell class '0' (zero) nitrile rubber insulation with factory laminated aluminium foil complete with other accessories such as adhesive, jointing taps, etc. as per tender technical specifications. | 420 | Sq.mtr. | - | - |
| 4 | Duct Acoustic Insulation- Open cell elastomeric foam based synthetic rubber (NBR) class 1 density 140-180 Kg/m3. 15 mm thick in sheet form . | 110 | Sq.mtr. | - | - |
| 5 | G.I. volume control damper - Supply, installation and testing of manually operated, multilouvered, opposed aerofoil blade G.I volume control damper with aluminum paint, outer body frame and having blades fabricated out of 1.5mm (minimum) thick extruded G.I section complete with other accessories such as locking arrangement, gear train, handle, position indicator etc. as per tender technical specifications. | 10 | Sq.mtr. | - | - |
| 6 | Supply and installation of combined motorised fire cum smoke control damper as per UL 555 and UL 555S complete with fire & smoke sensors, actuator, control panel and other accessories as per tender technical specifications. | 10 | Sq.mtr. | - | - |
| 7 | Supply and installation of Sound Attenuator of length 1500 mm with GSS casing splitters, fiber glass tissue paper for covering with SS perforated sheet etc. suitable as per technical specification | 2 | Nos. | - | - |
| 8 | Air-cooled DX Condensing Units - ( 8.5 TR )-Supply, installation, testing & commissioning of Air-cooled condensing units for DX type AHU complete with hermatically sealed compressor (Scroll compressor), copper refrigerant pipings duly insulated with preformed aluminium foil preclad nitrile rubber sleeves insulation of 19 mm thick (the average distance between condensing units and AHU shall be approximately 15 meters), refrigerant gas & oil charge. Inbuilt safety cutouts viz. High Pressure, Low Pressure & Oil Pressure switches etc., thermostatic expansion valves, thermostats for tripping the compressors after reaching the temperature of conditioned area to maintain required temperature in conditioned area. Air cooled condenser coil with suitable size fan and motor along with angle frame & vibration isolation pads for mounting the unit. The units to be connected to AHU with DX coil. All other materials, components and accessories required for proper functioning and installation of the units shall be included in present scope of work. | 10 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 5.92 MB
BOQ.pdf
Tender Documents • 0.28 MB
NITSCAN.pdf
Tender Documents • 5.91 MB
TechnicalSpecifications.pdf
Tender Documents • 2.61 MB
SGF.pdf
Tender Documents • 0.85 MB
SheduleB.pdf
Tender Documents • 0.06 MB
CONDITIONandCLAUSEOFCONTRACT.pdf
Tender Documents • 2.33 MB
ductingdrawing.pdf
Tender Documents • 0.21 MB
BOQ_971476.xls
BOQ • 0.31 MB
4424Corrigendum.pdf
PDF • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .