| 1 | L1₹48.5 LAccepted-AOC PLOT NO 39 SHRI SHIVE NAGAR 05 MOTI BANDHA MACHEDA HARMADA JAIPUR 302013 RAJ | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹49.6 L+₹1.1 L (2.30%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
PROVN OF INFRASTRUCTURE AND CONNECTED EXTERNAL SERVICES AT BLDG NO 36 OF NFS NODE UNDER GE SOUTH JAIPUR
2024_MES_689852_2
CWE/82396/JPR(S)/E8
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH JAIPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE SOUTH
₹90,000
Yes
8 May 2025
28 Jan 2025
22 Feb 2025
28 Jan 2025
20 Feb 2025
5 Feb 2025
28 Jan 2025 - 4 Feb 2025
Amount
Schedule `A' Part -I Lump sum price worked out by contractor for PROVN OF ANTISTATIC FLOORING services etc, complete all specified.
Lump sum price worked out by contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-II *Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-III *Above/below the lump sum price inserted by the MES in Schedule `A' Part-III
Lump sum price worked out by the Contractor for Schedule `A' Part-IV (MISC SCHEDULE) (rate against Srl No. 4.01 to 4.30 shall be quoted by the Contractor)
Providing and fixing homogeneous compact antistatic vinyl flooring of 2mm thickness in tile or role form all as specified and as directed(Note : the rate of any roughning/chemical required for fixing the vinyl flooring included in same item). (Make: Armstrong,LG,Wonder Floor)
S&F false ceiling tile dust free type and of non cumbustible material. Main tee of size 3000 x 24mm at every 1200 mm c/c max and rotary stiched.1200mm cross tee at every 600 mm c/c and 600mm cross tee at every 1200mm c/c max and wall angle all around the wall to form a grid of 600mm x 600mm and suspending the grid using 2mm GI rod and 6mm raw plug at every 1200mm intervals at the main tee and laying the ceiling tiles of size 595 mm x 595mm x 15mm over the formed grid having the fire rating of 60 minutes as per BS 476/23 of 1987, Noise reduction coefficeint (NRC) of 0.5-0.6, to resist temprature and humidity conditions up to 40 degrees (104 deg F) and humidity of 99% RH should be installed etc complete all as specified and directed.(Make: Armstrong, USG, TECHNO, Rockfon)
M&L for taking down sub main wiring of copper with PVC/steel conduit complete all as specified and directed.
M&L for taking down unserviceable DBs /Sheet Metal Enclosures of any type disconnecting carefully and making good disturbed surfaces complete all as directed.
Supply and fix MCB 10 KA conforming to IS-8828 : 1996 : IEC-898 : 1995 rupturing capacity of rating 06 to 32 Amps SP complete all as specified and directed.
Supply and fix MCB 10 KA conforming to IS-8828 : 1996 : IEC-898 : 1995 rupturing capacity of rating 32 to 63 Amps SPN complete all as specified and directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2.0 TR
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desiged for input variation between 170V to 250V with output voltage stabilied at 230V with accuracy of +/_ 2.5 % and of capacity 5.0 KVA with 2 to 3 minutes time delay relay, overload load protection as per model No VG 500 of V- Guard Make. or equivalent in LG/Vintek.
S& F factory made Sheet metal enclosure Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SPN of size 20 amps rating for connection of Spilt AC.
Supply fixing and installation of biometric Type Access Control system (ACS) for server room and UPS/Battery room including control of doors from Access Control system after proper programming in system and response time should be in permissible limit as per IS standard all connecting accessories Access Control Biometric Machine, Control Panel, Connecting data cables, Programming as requiredby user, arrangement of AC/DC supply and any chip/data card complete all as specified and directed.
Supply and fix UPS Input and Output Panel and cabling to racks with NEMA Sockets 02 Nos. for each Rack(Total 06 Nos.) complete all as specified and directed.
Supply, install and testing of CCTV Camera around/in NFS Node. Description of item as under:- 8ch dvr cp plus - 01 nos 2.4mp cp plus camera - 05 nos Hdd 4td - 01 nos Smps 12/volt - 01 nos 3+1 wire - 02 nos including other accessories and installation all as specified & directed.
Supply and fix fire hydrant cylinder (04 Nos.)containing CO2 of 10/15 kg capacity with proper stand and including basket filled with sand with duly coloured as per directed.
Fire Alarm System Supply, Installation, Testing and commissioning Detectors Complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combination detector Photoelectric /Optical with base with self built intelligence as per IS: 11360
Supply, Installation, Testing and commissioning of rate of rise heat detector Grade-I addressable analogue type heat detectors with solid state design wiith sensing element combination of fixed type and rate of rise of temperaturei ndicating LED mounting base etc as required complete as as specified.
Supply, Installation, Testing and commissioning of fault isolation module to electrically isolate different section of detector loops complete all as specified and directed.
Supply, Installation, Testing and commissioning Addressable type manual fire alarm boxes (MCP/Pull Boxes) Shall on command from the control panel send data to the panel representing the state of the manual switch and the addressable communication module status. Manual fire alarm boxes shall be constrcted of laxan with clearly visible operating instructions provided on cover. the word Fire shall appear on front of station in raised letters 1.75 Inches (44mm) or larger etc as required complete all as specified and directed.
Supply, Installation, Testing and commissioning of microprocessor based loop UL/EN542 loop (inbuilt 1 loop) Addressable fire alarm control panel as per NFPA72 approval. The panel shall be able to give pin point location of addressable units via the address code for each unit, total 242 devices can be connect in single loop. The panel shall also be able to automatically switch off all control switches when ever any alarm is triggered. The panel shall have built in Buzzer SMF batteries for min 7 Hrs back up, Battery charger, rectifier loop interfacecards, communication modules, LCD unit to indicate fire/Fault signal of individual unit option for external printer to log all incoming data etc complete in all aspects.
1-loop (Total 1x242 devices can be connected in 1-loop panel)
Supply, Installation, Testing and commissioning of following modules suitable for addressable fire alarm control panel.
Monitor modules for flow switch connectivity with main fire panel.
Supply, Installation, Testing and commissioning of addressable type loop sounder with storb light with 85 db audiable etc as required complete all as specified and directed.
Supply, Installation, Testing and commissioning of 20 mm PVC conduit with all connecting accessories as required.
Supply, Installation, Testing and commissioning of 2 core 1.5 sqmm PVC coated FRLS cables complete all as specified and directed.
M & L for wall cutting as required for Steel/GI conduit passing and making good disturbed surfaces complete with proper PCC work all as specified and directed,
M & L for foundation and PCC work for main fire panel including mounting structures and nut, bolts with connecting accessories complete all as specifies and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised using iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Material & Labour for chemical earthing complete with pure copper earth plate electrode (98% condutivity when annealed) of size 900 mm x 600 mm x 5 mm thick buried directly in ground (earth pit not less than 4.00 m deep below normal ground level) with top edge of the plate not less than 4.00 m deep below normal ground connected to and including copper earth strip 32 mm x 6 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG, Crystal salt 200 KG, magnesium sulphate of 150 KG and vegetable soil all around the plate up to 350 mm above from top edge of plate and ballance portion filling with excavated soil in layers n.exc 25 mm thick, 15 mm bore galvanised iron medium grade watering pipe, 40 mm bore galvanised iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete, RCC 1:2:4, type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/ sqm) with cast iron frame, funnel with wire mesh, test point etc complete all as specified and directed. Note : (i) Earth strip and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item. (ii) The earth resistance value shall be less than 1 Ohm. Failing to achieve the value contractor shall re-do without any extra cost.
Supply, installation, commissioning and testing complete of Manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 82.5 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 Phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall comprise of the following : - (a) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, radiator and all standard fittings/ fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter ( 12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent of Cummins make or equivalent KIRLOSKAR (KOEL) / GREAVES. (b) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase , 4 wire type, rated for continuous output of 82.5 KVA, PF 0.8 (lag), 1500 RPM insulation class ‘H’; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1 % voltage regulation, coupled directly / suitably to and to match the above engine and conforming to BS 5000/IS 4722 .Alternator makes shall be KIRLOSKAR/ STAMFORD/ GREAVES/BHARAT BIZLEE.
(c) Dunlop Metallastik anti-vibration pads for mounting engine – alternator assembly on the base frame/ plate. (d) Base plate : Made out of structural steel as per manufacturer’s recommended design/ specifications. (e) Enclosure : Provision of an integral type, approved / certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 – 7 degree celsius. It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window. The base frame shall be of ISMC . It shall also include the following: - (i) Silencer: Absorption type, non-resistance, residential. (ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings. (iii) Fuel tank to be provided as per OEM specification. (iv) Safeties for high enslosure temperature and emergency shut-down from outside. (v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design / specifications. (f) Control panel : Contro panel made out of 14 gauge CRCA sheet , powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals. (iii) Indicating lamps for load on and 'set running' (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protectons. Note: To be mounted inside enclosure.
M.S. ENTERPRISES (BID ID -3237647)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .