Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.2 L+₹98,294 (9.64%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹15.2 L
EMD Value
₹30,300
Closing Date
14 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Navy) Lakshadweep
GE (Navy) Lakshadweep C/o NOIC (LAM) Navy Office Coast Guard Road Kavaratti Islands UT of Lakshadweep-682555
REPAIRS/MAINTENANCE TO DG SETS AND EXTERNAL WATER SUPPLY SUCH AS REWINDING OF MOTORS, REPAIRS TO PUMP SETS, REPLACEMENT OF PIPE LINES AND REPAIRS TO STARTER IN KAVARATTI ISLAND UNDER GE NAVY LAKSHADWEEP
2024_MES_637313_1
8385/E8
Open Tender
Electrical and Maintenance Works
Item Rate
Garrison Engineer Navy Lakshadweep
As per NIT and Tender document
6 documents required · 6 mandatory
₹500
Garrison Engineer (Navy) Lakshadweep
₹30,300
Yes
9 Mar 2024
13 Jan 2024
17 Feb 2024
13 Jan 2024
14 Feb 2024
27 Jan 2024
13 Jan 2024 - 18 Jan 2024
Amount
DG SET M&L for maintenance and servicing of DG Sets (B check) comprising Prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc including checking lubricating oil, coolant, filters, V-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner, attending faults of AMF panels and replacing the defective parts (as per B check i.e. filters, gasket kits, O ring, oil, coolant etc) and identifying malfunction of the DG Set (if any) of following capacities complete all as specified and directed by Engineer-in-charge. Notes for all Items :- (a) Major spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only. (b) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job.. (c) Labour component for fixing the spares during above servicing including testing the DG set for rated output is deemed to be included in the quoted rate. (d) The following items will be operated only if found necessary at site during the maintenance period. The contractor has no claim over the operation of full amount / spares under these items and payment will be made only for the spare parts actually replaced at site and as per the agreed rates.
(a) DG Set of capacity 20 KVA (Model No. KG1-20WS)
(b) DG Set of capacity 30 KVA (Model No. KG1-30WS)
(c) DG Set of capacity 45 KVA (Model No. ALGPWO417MK1E4)
(d) DG Set of capacity 62.5 KVA (Model No. AL4CTIDG5)
Dismantling radiator assembly from the engine of 62.5 KVA capacity DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, assembling back including necessary welding and with additional bracket as required. Refixing, reconnecting and testing for proper functioning complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item No 2 above but for DG Set of capacity 30 KVA
Ditto all as per item No 2 above but for DG Set of capacity 45 KVA
Ditto all as per item No 2 above but for DG Set of capacity 20 KVA
Dismantling of fuel injection pump assembly complete from the engine of DG Sets, servicing, over hauling, replacement of valves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing all as directed by Engr-in-charge for the following capacity :-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Disconnecting and taking down outgoing cables from the DG sets and cutting removing the burnt cable ends and thimbling and refixing back including provision of cable glands, lugs, tools and testing complete for the following capacites of DG setscomplete all as specified and directed by Engineer-in-charge.:-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply only (in replacement) spin on fuel filter (pre and fine filter) element with O ring for generator set of following capacity complete all as specified and directed by Engineer-in-charge.:-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply only (in replacement) Dry type Air filter element Inner and Outer unit as required at site with O' Ring of suitable for following capacity DG Set complete all as specified and directed by Engineer-in-charge.:-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply only (in replacement) Lub oil filter element with O Ring suitable for following capacity DG Set complete all as specified and directed by Engineer-in-charge.:-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply only (in replacement) By pass filter element with O ring of suitable for following capacity DG Set complete all as specified and directed by Engineer-in-charge..
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply only V-belt suitable for following capacity DG set including removing old unserviceable fan belt all as specified complete all as specified and directed by Engineer-in-charge.:-
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply and fixing (in repairs) Water Pump Assy suitable for following capacity DG set including removing old unserviceable water pump assy complete all as specified and directed by Engineer-in-charge.:
(a) DG Set of capacity 20 KVA
(b) DG Set of capacity 30 KVA
(c) DG Set of capacity 45 KVA
(d) DG Set of capacity 62.5 KVA
Supply & fixing common rail diesel sensor suitable for DG Set engine complete all as specified and directed by Engineer-in-charge.
Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator complete all as specified and directed..
Supply and replacement Lub oil pipe armoured of suitable length and socket size complete all as specified and directed by Engineer-in-charge.
Supply and replacement Anti vibration rubber pad for side radiator complete all as specified and directed by Engineer-in-charge..
Supply and replacement Lub oil pressure guage 0 to 10 kg / sq cm complete all as specified and directed by Engineer-in-charge..
Supply and top up coolant oil complete all as specified and directed by Engineer-in-charge..
Supply and top up engine oil 15W40 grade complete all as specified and directed by Engineer-in-charge.
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and directed by Engineer-in-charge.
Supply and top up Battery Distilled water complete all as specified and directed by Engineer-in-charge.
Supply and fixing SMPS battery charger 12V/24V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cable drawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and directed by Engineer-in-charge.
Disconnecting, dismantling 12V/24V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed by Engineer-in-charge.
Supply and fixing (in repairs) AVR (Auto Voltage Regulator) suitable for Gen Set having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz for the following capacities complete all as specified and directed by Engineer-in-charge. :-
(a) 20 KVA to 45 KVA
Supply and fixing in replacement of Digital DG Controller suitable for any type DG Set of any capacity complete and connecting with existing electrical circuit all as specified and directed.
Supply and fixing (in repairs) Diods set(Rectifier) of Main alternator of DG Set of capacity 20 KVA complete all as specified and directed.
All as per item No 27 but for DG Set capacity 30/45 KVA
All as per item No 27 but for DG Set capacity 62.5 KVA
Supply and fixing (in repairs) Contactors 4 pole, 63A, coil volt-240volts, AC 50Hz all as specified and directed
Supply and fixing (in repairs) Contactors 4 pole, 100A, coil volt-240volts, AC 50Hz all as specified and directed
Supply and fixing (in replacement) CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed.
Supply and fixing (in repairs) fuse unit 12 V DC (as per sample) suitable for DG Set control panel all as specified and directed.
M&L Minor Repair/cleaning of fuel tank, removing sludge, arresting leak using metal paste/sealent or by welding/soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site complete for the following Gen Set :-
M&L for minor repair to canopy such as to hinges, locking arrangement etc and painting inside/outside area of DG Set 62.5 KVA comprising engine, alternator, genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint cleaning scrubbing of all surface including writing by paint the SM/MES numbers etc all as specified and all directed by Engr-in-charge.
All as per item No 35 above but for 20/30/45 KVA Genset
Dismantling, removing the self starter, motor from the engine of following capacity DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed for the following DG set:-
(a) DG Set of capacity 20/ 30 / 45 KVA
(b) DG Set of capacity 62.5 KVA
S&F asbestos rope 12 mm dia wrapped over the exhaust pipe and painting with heat proof paint of approved colour including taking down the old rope all as specified and directed.
Supply and fixing in replacement LED phase indicator lamp assy RYB complete all as specified and directed by Engineer-in-charge.
Supply and fixing (in replacement) Water separator suitable for DG sets of capacity 62.5 KVA complete all as specified and directed by Engineer-in-charge.
All as per item No 42 here-in-before but DG Set of Capacity 20 KVA to 45 KVA
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point all as specified incl testing on completion complete all as specified and directed by Engineer-in-charge.
S&F DG Set diesel tank lock (as per sample) with fixing accessories complete all as specified and directed by Engineer-in-charge.
M & L for checking of AMF panels including replacement of unserviceable parts such as Relays, Timers, Power contactors, Auxilary contactors, defective copper wiring, MCCBs etc. for DG Set, complete all as specified and directed by Engineer-in-charge. Note: - Spare parts shall be measured and paid separately under Supply only items
Supply only Auxiliary contactor 240 V 3 No & 1 NC
Supply only ON and OFF delay timer 240 V AC
Supply only Earth fault relay.
Supply only Over load relay.
Supply only Under voltage relay.
Supply only DC power contactor for auto starting 12 V
Supply only Power Contactor MCX 22, 4 Pole
Supply only Power Contactor MCX11, 4 Pole
Supply only Power Contactor MCX 33, 4 Pole
Supply and fix in replacement of Power Contactor MNX 70 , 3P , 415 V including necessary wiringcomplete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Power Contactor MNX 110 , 3P , 415 V including necessary wiring complete all as specified and directed by Engineer-in-charge.
Dismantling of 62.5 KVA Capacity alternator from Generator after Dismantling from Generator shifting to workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, reassembling of alternator, bringing back to the sight refixing and installation and foundation with proper alignment, testing and commissiong complete all as directed by Engr-in-Charge. Note :- Taking up and down from the site to workshop with vehicle and labour is deemed to be included in quoted rates.
All as per item No.59 herein above but of capacity 20/30/45KVA
WATER SUPPLY Dismantling the centrifugal /submesible pump set of capacity 1 HP and transportation to workshop for replacing unserviceable parts such as impeller,shaft, bearing, winding etc and reconnecting back the pumpset to its original position after repair and testing complete all as specified and directed by Engineer-in-charge.
All as per item No.61 above but of capacity 1. 5 HP
All as per item No.61 above but of capacity 2.0 HP
All as per item No 61 above but of capacity 5.0 HP
Disconection and removing the defective star/delta starter and S & F the new star/delta starter three phase 440 Volts , 50 Hz with relay rating 14-23A suitable for motor capacity up to 5 HP testing complete all as specified and directed by Engineer-in-charge.
Disconection and removing the defective DOL starter and S & F the new DOL starter three phase 440 Volts , 50 Hz suitable for motor capacity up to 5 HP testing complete.
S & F in replacement of DOL starter single phase 240 Volts , 50 Hz suitable for motor capacity & testing complete all as specified and directed by Engineer-in-charge.
S&F in replacement of over current relays suitable for single phase DOL starter and testing complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of PVC foot valve complete all as specified and directed by Engineer-in-Charge of following sizes:-
a) 65 mm bore
b) 50 mm bore.
c) 40 mm bore.
d) 32 mm bore.
Supply and fix in replacement of CPVC ball valve complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC brass elbow complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC brass tee complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC male brass threaded adaptor complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC female brass threaded adaptor complete all as specified and directed by Engineer-in-Charge of following sizes :-
Supply and fix in replacement of CPVC UNION complete all as specified and directed by Engineer-in-Charge of following sizes :-
Material and labour for cutting the existing hardstanding/road not less than 25cm in deep and 45cm in width for laying of CPVC pipes and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.
M&L construction of 200mm thick PCC solid block wall masonary valve chamber built in CM 1:6 with 150mm thick PCC foundation 1:2:4 type B-1 coping 50mm thick finished even and smooth, rendering 10mm thick in cement mortar (1:6), finished fair and and even externally including excavation earthwork in any strata, 6mm thick MS sheet cover fixed on angle iron frame 25x4mm embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surface with two coats of black bituminus paint over one coat of red oxide primer etc, complete all as specified and directed for internal size 600x600x600mm including the demolishing PCC Chamber complete all as specified and directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out soft/loose soil for laying pipes cmplete all as per specification and upto the satisfaction of Engineer in charge.
Returning filling in, with excavated soils incl. spreading, levelling, watering and well ramming in layers n.exc. 25 Cms. all as specified and directed and upto the satisfaction of Engineer in charge.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed and upto the satisfaction of Engineer in charge.
M/s PATEL ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .