Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC 59 INDU HOUSE RAMA ROAD INDUSTRIAL AREA 110015 | DELHI | WEST DELHI | DELHI | 110015 | ₹3.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹3.2 Cr+₹13.9 L (4.51%)Rejected-AOC | ₹3.2 Cr+₹13.9 L (4.51%) | L2 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹4.0 L
Closing Date
10 Feb 2021, 3:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Rohak
Establishment of ICU / HDU at Trauma Centre First Floor in Civil Hospital Bahadurgarh (Jhajjar) (Pdg. Medical Gas Pipe Line only)
2020_HRY_154736_1
PWD/Electrical/196619
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Jhajjar
Please refer to the tender documents as per DNIT Conditions.
3 documents required · 3 mandatory
₹15,000
₹4.0 L
Yes
28 Jun 2021
31 Dec 2020
15 Feb 2021
31 Dec 2020
10 Feb 2021
31 Dec 2020
Amount
A) MEDICAL OXYGEN SYSTEM
S/I/T/C of Oxygen Manifold with16 Nos. pigtailpipes for 8+8 clyinders and Non-returnvalves, as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. - (Indian) (without clyinders)
S/I/T/C of Fully Automatic Oxygen Control Panel, as per HTM-2022/02-01ofUK/NFPA99C of USA as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. - (Imported)
S/I/T/C of Oxygen Manifold Emergency for 4 Cylinders, as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.-(Indian) (without clyinders)
S/I/T/C of Oxygen Outlets with matching probes, as per HTM-2022/02-01ofUK/NFPA99C of USA as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. - (Imported)
S/I/T/C of Oxygen Flowmeter with Humidfier Bottle New Born CE Certified/UL Listed,as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Imported) for critical area
C ) MEDICAL COMPRESSED AIR SYSTEM
DESCRIPTION : S/I/T/C of Duplex compressed Air system as per tender specifications as per HTM 2022-02-01/ NFPA99C as per enlcosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work
S/I/T/C of Air-4Bar Outlets with matching probes, as per HTM-2022/02-01ofUK/NFPA99C of USA as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Imported)
D ) MEDICAL VACCUM CENTRAL SYSTEM
DESCRIPTION : S/I/T/C of Duplex Vacuum central system as per tender specifications as per HTM 2022-02-01/ NFPA99C as per enlcosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work
S/I/T/C of Vacuum Outlets with matching probes, as per HTM-2022/02-01ofUK/NFPA99C of USA as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Imported)
S/I/T/C of Ward Vaccum unit CE Certified / UL listed with suction jar ( capacity 1/2 Gallon ) and Low suction regulator complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (Imported) for critical area
E) S/I/T/C of MEDICAL Grade BS EN: 13348 Kite Marked COPPER PIPE complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (Indian)
F) S/I/T/C of MEDICAL AREA LINE PRESSURE ALARM-as per HTM 2022/02-01/ NFPA99C as per enclosed technical specifications complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (imported)
Area Line pressure Alarm-3 gases
Master Main Alarm including all Gases
G) S/I/T/C of MEDICAL AREA VALVE SERVICE UNIT ( VALVE BOX WITH ISOLATION VALVE) AS PER CE CERTIFIED /UL LISTED AS PER ENCLOSED TECHNICAL SPECIFICATIONS complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Indian)
3 Gases
H) S/I/T/C of MEDICAL LINE VALVE, AS PER CE CERTIFIED / UL LISTED AS PER TECHNICAL SPECIFICATIONS complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Indian)
I) S/I/T/C of Bedhead panel 1500mm length, with provision of Gas outlets & provision with electrical sockets & accessories complete as per enclosed tender technical specifications duly CE Marked complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. (Indian)
J) S/I/T/C of D type Oxygen Gas Clyinder complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work.- (Indian)
K) Annual Operation & Maintenance Comprehensive maintenance after one year free warranty period of MGPS & OT’s system of all the machinery equipments & installed in the building including Sunday & holiday (24x7x365) during five year as under including all labour and material (Including consumables) i) Operation & comprehensive maintenance after free warranty period.
1st year - During free maintenance period.Operation cost only
2nd year - Comprehensive maintenance & Operation
3rd year - Comprehensive maintenance & Operation
4th year - Comprehensive maintenance & Operation
5th year - Comprehensive maintenance & Operation
Condition: - For evaluation of lowest tenderer, price of AMC shall be included in the price bid of the tender. However separate agreement for operation of Mtc. shall be enforced after completion of work
Prime Technomed Solution Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .