Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹37.1 L+₹76,178.93 (2.09%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted than L1 | |
| 3 | L3₹38.4 L+₹2.0 L (5.54%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted than L1 | |
| 4 | L4₹39.5 L+₹3.1 L (8.59%)Rejected-Finance | L4 | Rejected-Finance Higher rate quoted than L1 | |
| 5 | L5₹39.7 L+₹3.4 L (9.30%)Rejected-Finance | L5 | Rejected-Finance Higher rate quoted than L1 |
Tender Value
₹49.5 L
EMD Value
₹99,100
Closing Date
14 Oct 2022, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_552469_1
8400-863/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D and Category a (i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹99,100
Yes
9 Dec 2022
16 Sept 2022
17 Oct 2022
16 Sept 2022
14 Oct 2022
30 Sept 2022
Amount
Excavating over areas, n.exc 1.5 m deep and getting out soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for foundation etc or for shafts n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed.
M&L for hardcore of broken stone of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for cement concrete (1:4:8) Type D2 (using 40 mm graded stone aggregates) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for PCC (1:3:6), 75 mm thick Type C2 (using 40 mm graded stone aggregate) used as in plinth protections and finishing cement concrete surface even and fair without using extra cement complete all as specified and directed.
M&L for PCC (1:3:6) 100 mm thick Type C2 (using 40 mm graded stone aggregate) used as in sub base of flooring complete all as specified and directed.
M&L for PCC (1:2:4) 75 mm thick Type B1 (using 20 mm graded stone aggregate) used as in flooring finished even and smooth without using extra cement complete all as specified and directed.
Preparation of steel surfaces of any description, priming with red oxide primer and painting with synthetic enamel paint n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed.
M&L for brickwork with modular fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces of wall, surface finished even and smooth without using extra cement complete all as specified and directed.
Preparing new surfaces of walls plastered and white washing with three coats of white wash on walls complete all as specified and directed.
Removing excavated spoil to a distance n.exc.50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section Fe 410 -W (Gde-E- 250)quality- A with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
Supply only chain link MS galvanised fencing of mesh size 75x75 mm with min dia of wire 3.5 mm of weight per square metre Not exc 4 kg , complete all as specified and directed by Engr-in-Charge. (Note : Fixing of chain link fencing will be measured and paid separately).
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed
S&F mild steel screw bolts (machine made)with hexagonal or square heads at one end and screw other and each screw end to be fixed with washers and nut exc 5 cm but n.exc 10 cm long complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and painting with two coats of cement based paint over a coat of alkali resistant priming paint complete all as specified and directed.
M&L for preparation of painting of new steel surfaces over 10 cm in width or girth over a coat of primer using red oxide and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for PCC (1:2:4) Type B1 (using 20 mm graded stone aggregate) used as in filling of concrete for fixing of angle iron members complete all as specified and directed.
S&F galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Note: Each line wire to be measured).
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
M&L for formwork for rough finished surface of concrete (flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed.
M&L for reinforced cement concrete (Design Mix) M-25 (using 20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in columns, pillars, piers, etc complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 26.00 mentioned here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillar, window-cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removing rubbish off from the premise complete all as specified and directed.
M&L for cement concrete 100 mm thick type B- 1, 1:2:4 (using 20 mm graded stone aggregate) laid on concrete floors and pavings, and finished even and smooth (except metallic hardner); laid over cement concrete sub floors etc. and finished to an even and fair surface without using extra cement complete all as specified and directed.
Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F 0.50 mm thick pre- painted galvalume aluminium zinc coating GI based corrugeted steel sheet of any colour as approved of 550 Mpa tensile strength as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in ridges, hips valley gutter etc fixed with self tapping screws complete all as specified and directed.
Dismantling asbestos cement plain building boards from ceiling including cover fillets complete all as specified directed.
S&F anodised aluminium snap grid frame work size of grid 605 x 605 mm for false ceiling all as specified
S&F hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed.
S&F Non asbestos fibre cement building boards (designer type) 6 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls or from concrete surface incl racking out joints hacking for key scrubbing with water and removing rubbish off from the premise etc complete all as specified and directed.
M&L for rendering 20 mm thick in CM (1:4) on other than fair face of brick work surfaces with WPC finished even and smooth with out using extra cement all as specified. (Note: WPC shall be measured and paid seperately)
Supply only integral water proofing compound complete all as specified and as directed. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for preparation of newly plastered surfaces of wall & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior (weather coat) paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work surfaces finished even and smooth with out using extra cement all as specified.
Preparation of new plaster wall surfaces and applying three coats of whitewash complete all as specified as directed.
S&F wire netting of galvanised steel wire 0.71 mm dia and size of mesh is 12 mm fixed in properly with suitable nails for repair of cracks at various locations in wall, beam,chajja, facis, slab, lintel etc including taking down plaster of cracked portion and cutting grooves for receiving chicken wire mesh and making good the area by 15mm thick rendering in CM (1:3) complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified as directed.
M&L for reinforced cement concrete (Design Mix) M-25 (using 20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified as directed.
Taking down chowkats or frames with shutter w/o taking off shutter from the frame n.exc 1.5 Sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified as directed.
S&F steel ventilator with top hung shutter (minimum wt. of steel section should be 1.42 kg/M) including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including taking down existing unserviceable one including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S&F steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
S&F sheet glass 5.5 mm thick , ordinary quality and glazing with oil putty in square n.exc 0.5 sq. m in each pane complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for preparation of painting of old steel surfaces over 10 cm in width or girth over a coat of primer using red oxide and applying two coats of synthetic enamel paint complete all as specified and directed.
Taking down chowkats or frames with shutter w/o taking off shutter from the frame exc 1.5 Sqm & n. exe 4 Sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) all as specified and directed By Engr-in-charge.
S&F plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood complete all as specified and directed.
S&F plain, framed, panelled shutters 40 mm thick (any number of panels) in 2nd class Hardwood , with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
M&L for preparation of wooden surfaces and applying 02 coats of synthetic enamel paint over a coat of pink primer of any description, not otherwise described, over 10cm width or girth complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 as in bed blocks for hold fast, kerb, coping including necesssary formwork complete all as specified and directed.
S&F mild steel flat iron as in hold fast, clamps articles conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F 100 mm size butt hinges extruded aluminium alloy with galavanised mild steel hing pin anodised and fixed type C-21 complete all as specified and directed
S&F 200 mm long aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150mm long complete all as specified and directed
S&F 300 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
S&F steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L for 100mm thick plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 75mm thick cement concrete type B- 1,1:2:4 (using 20mm graded stone aggregate) as in hardstanding/pavement complete all as specified and directed.
M&L for forming contraction with using Grade 'A' (Dummy) joints 50mm deep x 10mm wide, filled with sealing compound Grade'B' complete all as specified and directed
M&L for chequered cement concrete coloured tiles of size 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry ( with grey cement and pigment) after and including 20mm thick screed bed in cement mortar (1:6) for fixing tiles compplete all as specified and directed.
M&L for parking tiles 10mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed or bedding layer of 15 mm thick with cement mortar 1:6 and pointed in white or coloured cement to match complete all as specified and directed. (Make : Endura of Johnson or equivalent model as approved by the GE).
M&L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed.
E/M PORTION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 74.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface).
M&L for point wiring for socket outlet 3 pin, 5 amps on Independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes/ modular , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed .( For Same Board only)
S&F switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
S&F sub main two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire including taking down old one complete all as specified and directed. (Note: (i) Three runs cable and conduit pipe will be measured as single unit. (ii) Quoted rate deemed to be included for necessary chasing/cutting and making good the surface).
S&F sub main two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire including taking down old one complete all as specified and directed. (Note: (i) Three runs cable and conduit pipe will be measured as single unit. (ii) Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F 01x 22 W LED batten light fittings, complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as directed.
S&F in repair security light fittings 25 watts, minimum lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
S&F in repair flood light fittings 60 watts, made up of pressure dia cast housing with prismatic polycarbonate diffuser and individual LED with secondary optic and IP66 including necessary connection complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings including LED bulb 7 Watts, 240 Volts complete all as specified.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCCBs to be used), double pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Vertical Triple pole and neutral 415 V, 8 ways up to 250 Amps with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP, 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB TPN 40-63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 250 Amp, 25 KA complete with proper copper thimbles, copper reducer etc all as directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or riveted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate up to equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submitted to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
S&F heavy duty steel body Exhaust ventilation fan of sweep 300mm with louvers and making a suitable hole and plaster the disturbed area complete all as directed by Engr-in-Charge.
S&F XLPE insulated armoured cable, 35 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminum conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed including taking down old one complete all as specified.
S&F XLPE insulated armoured cable, 16 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed including taking down old one complete all as specified.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
Jaibalaji Enterprise
M/S SWAPAN KUMAR MONDAL
M/S S M ENTERPRISE
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
FRIENDS CONSTRUCTION
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
UNIVERSAL TRADING
NATIONAL CONSTRUCTION CO
JOTSHNA ELECTRICALS
M/s Santosh Industrial Corporation
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .