Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC KHAWAS BUILDING BELOW PAIZOR STADIUM GANGTOK 737101 SIKKIM | GANGTOK | EAST DISTRICT | SIKKIM | 737101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.4 L+₹3.0 L (14.7%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹24.1 L+₹3.7 L (18.2%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹24.3 L+₹4.0 L (19.4%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹24.6 L+₹4.2 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
26 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gangtok
GE Gangtok New Mil Stn Gangtok, Sikkim 737102
REPAIR MAINT OF EXTERNAL LT ELECTRIFICATION AT NEW CANTT UNDER GE GANGTOK
2022_MES_537497_2
8048AE8
Open Tender
Electrical and Maintenance Works
Works
182 days
GE Gangtok New Mil Stn Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹40,000
Yes
10 Dec 2022
1 Nov 2022
28 Nov 2022
1 Nov 2022
26 Nov 2022
8 Nov 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of cable & pole foundations and getting out in soft/loosse soil complete all as specified and as directed.
Returning filling in soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removal of surplus excavated material (soil) to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supply and laying DWC PE cable duet pipe ISI marked trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc.conforming to IS 16205, (Part 24) and cutting, jointing etc of size 50 mm outer dia complete all as specified and as directed by the Engr-in-charge
Supply and laying DWC PE cable duet pipe ISI marked trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc.conforming to IS 16205,Part 24 and cutting, jointing etc of size 75 mm outer dia complete all as specified and as directed by the Engr-in-charge
Taking out old unserviceable, burnt punctured aluminium conductor cable LT, PVC 1100 volts grade, of following cross sectional area from the excavated trenches, ducts laid in floors, along poles/ walls / equipments etc. Laid and passed through pipes or laid bare in road crossing/drains/paths/along walls /poles/floors etc and in similar locations complete all as specified and directed by the Engineer-in-Charge:- (a) 150 Sqmm 3.5 core
All as per item No 6 above but 120 Sqmm 3.5 core
All as per item No 6 above but 95 Sqmm 3.5 core
All as per item No 6 above but 70 Sqmm 3.5 core
All as per item No 6 above but 50 Sqmm 3.5 core
All as per item No 6 above but 35 Sqmm 4 core
All as per item No 6 above but 25 Sqmm 4 core
Supply and laying in trenches/through pipes or bare in road crossing/paths/drains/ducts/floors/along ploes/walls/ceiling equipments etc, cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sctional area all as specified and directed by the Engr-in-charge:- (i) Earthwork & excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule. (ii) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes. (a) 150 Sqmm 3.5 core
All as per item No 7 above but 120 Sqmm 3.5 core
All as per item No 7 above but 95 Sqmm 3.5 core
All as per item No 7 above but 70 Sqmm 3.5 core
All as per item No 7 above but 50 Sqmm 3.5 core
All as per item No 7 above but 35 Sqmm 4 core
All as per item No 7 above but 25 Sqmm 4 core
M&L for taking out faulty UG cable cutting faulty end, supplying and making straight through joint with heat shrinkable kit outdoor including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV volts grade complete of following cross ectional area :- (Note : Excavation & earth work, DWC pipe for protection if necessary will be measured and paid sepatately) (a) 120 to 185 Sqmm 3.5 core-
All as per item No 8 above but 70-95 Sqmm 3.5 core
All as per item No 8 above but 25 -50 Sqmm 3.5/4 core
Laying only cable obtained against item No. 6 here in before, in trenches/through pipes or bare in road crossing/paths/drains/ducts/floors/along poles/walls/ceilling/equipments etc of following cross sectional area, all as specified and directed by the Engr-in-Charge:- (i) Earthwork & excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule. (ii) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes (a) 150 Sqmm 3.5 core
All as per item No 9 above but 120 Sqmm 3.5 core
All as per item No 9 above but 95 Sqmm 3.5 core
All as per item No 9 above but 70 Sqmm 3.5 core
All as per item No 9 above but 50 Sqmm 3.5 core
All as per item No 9 above but 35 Sqmm 4 core
All as per item No 9 above but 25 Sqmm 4 core
Taking out old unserviceable, GI tubing of any size upto 80mm bore from the excavated trenches, ducts, floors, along poles/walls/equipements, road crossing/drains/paths etc all as specified and directed by the Engineer-in-Charge
Supplying and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables :- Note : Payment for excavation and earth work shall be paid for separtely under relevant items of schedule (a) 80 mm dia
Supplying and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables :- Note : Payment for excavation and earth work shall be paid for separtely under relevant items of schedule (a) 50 mm dia
Disconnecting all cable connections and taking out u/s MCCB/MCBs any type/ capacity upto 250 AMPs, TP/FP/TPN, 415 Volt from Panel Boards/feeder boxes and remove from site
Supply and fixing following rating annd breaking capacity MCCB with thermomagnetic release and terminal spreders in existing cubicle panel board including drilling holes in cubicle panel, making connections, connecting up using suitable size of lugs etc. as required and directed by the Engr-in-Charge:- (a) MCCB, 4 Pole, 400 Amps, 415 Volt, 25 KA
All as per item No 14 above but MCCB, 4 Pole, 250 Amps, 415 Volt, 25 KA
All as per item No 14 above but MCCB, 4 Pole, 200 Amps, 415 Volt, 25 KA
All as per item No 14 above but MCCB, 4 Pole, 160 Amps, 415 Volt, 25 KA
All as per item No 14 above but MCCB, 4 Pole, 125 Amps, 415 Volt, 18 KA
All as per item No 14 above but MCCB, 4 Pole, 100 Amps, 415 Volt, 18 KA
All as per item No 14 above bu MCCB, 4 Pole, 63 Amps, 415 Volt, 18 KA
Supply and fixing in repairs 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN-40A = 2 No and TPN-50-63A = 4 No and current carrying capacity in the DB with connection testing and commissioning.
Supply installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50 x 50x 6mm thick angle inron frome work upto height of 0.9 mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including followng spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (a) MCCB 4 pole, 18 KA 100 Amp-01 No (incommer) EPS Cat No CSESZ 125FMU4P100A. (b) MCCB 4 pole 25 KA 63 AMP-03 (Outgoing) EPS Cat No CSESZ 125FMU4P063A Add: Make of LT Panel : C&S/ABB/Schneider/Adhunik/Neptune/BCH. (c) Phase indicating lamps (R-Y-B) - 01 set (d) Multifuncitoning meter with necessary CTs
M&L for earthing complete in repairs with advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (zinc & alloy coated), ZINC coated (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250) microns. Earthing System confirming IS 3043. The outer and inner pipe should be 48.3mm & 26.4mm 2mtrs length, zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the terminal. The annular space between the pipes being filled up with COMPACT FILL (CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity, The job includes digging the pits and refilling the same by BARONS electrodite OR conductolite back fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON or MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 to 4 bags ELECTRODITE OR 2.4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH. ELECTRODE. The electrode should be of galvnised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 x 6mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as
M&L for plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as finishing road/concrete surface coping of poles including finishing to exposed concrete surfaces even and fair complete all as specified
M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for paossing of bcable through GI pipe returning filling in complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) upto 20 cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note (i) GI pipes shall be measured and paid separately. (ii) Any damage made/caused to the HT/LT cables, Water Supply pipelines, OFC cables etc during the excavation works shall be made good by the contr as per original & to the eintire satisfaction of Engr-in-Charge & GE Cost of the same is deemed to be included in the unit quoted rates.
DHARMINDER SINGH
M/S ANIL KUMAR THAKUR
M/S S. S CHETTRI AND SONS
M/S MANOJ VERMA
RAAJ BANGAR
KARMA TSETEN BHUTIA
BIJAY MITTAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .