Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 2 | Rejected-Technical 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | Rejected-Technical Technically Not Qualified |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
19 Aug 2026, 3:00 pmClosed
Executive Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, KeshavChowk, Delhi-110053
Improvement of permanent pumping station at Mansarover Park under Shahdara North Zone.
2026_MCD_286391_1
EE(E)-II/SNZ/MCD/26-27/TC-9/1
Open Tender
Electrical Works
Percentage
270 days
As per NIT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
₹2.7 L
22 Sept 2026
3 Aug 2026
19 Aug 2026
3 Aug 2026
19 Aug 2026
3 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply installation testing and commissioning of Electrical Horizontal centrifugal pump set with non clog /mf impeller to handle storm / mixed / sewage water with having min. discharge of 800 m3/hr at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia ,mounted on a common base frame coupled with Min. 40 HP or suitable rating (IE-2) three phase, TEFC AC , 415 volts, 50 Hz supply electrical Motor energy efficient complete as required. Mounted on a common base frame as Casing C I, Impeller C I, Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd. | 4 | Each | 5,86,276 | ₹23,45,104 |
| 2 | P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 400 mm ,9.5 mm thickness | 8 | Meter | 25,333 | ₹2,02,664 |
| 3 | P & F/Replacement of M.S Black pipe Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 150 mm, 5.4mm thickness | 8 | Meter | 1,787 | ₹14,296 |
| 4 | 350 mm ,9.5 mm thickness | 20 | Meter | 13,283 | ₹2,65,660 |
| 5 | P & F/Replacement of M.S Black pipe (9.5 mm thickness) Conforming to IS:3589 with required nut bolts and packing sheet etc complete as reqd of following dia 300 mm ,9.5 mm thickness | 12 | Meter | 12,070 | ₹1,44,840 |
| 6 | Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness) | 8 | Each | 4,456 | ₹35,648 |
| 7 | Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 350 mm ( 25 mm thickness) | 23 | Each | 3,677 | ₹84,571 |
| 8 | Providing & Fixing of M.S Flange with required nut bolts and packing sheet etc complete as required of following dia. 150 mm ( 10 mm thickness) | 4 | Each | 672 | ₹2,688 |
| 9 | 300 mm ( 25 mm thickness) | 16 | Each | 3,032 | ₹48,512 |
| 10 | Providing & Fixing of M.S Blind Flange with required nut bolts and packing sheet etc complete as required of following dia. 400 mm ( 25 mm thickness) | 4 | Each | 6,940 | ₹27,760 |
stage.html
html • 0.03 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.06 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.16 MB
circular.pdf
Tender Documents • 9.28 MB
GCC2024.pdf
Tender Documents • 9.36 MB
MSParkTermsandConditions.pdf
Tender Documents • 0.63 MB
Circular_1.pdf
Tender Documents • 2.39 MB
BOQ_334223.xls
BOQ • 0.38 MB
Corrigendum_2026_MCD_286391_1.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .