| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC FLAT NO 1004 BUILDING NO L 11 KEDAR HOUSING SOCIETY 10TH FLOOR SECTOR NO 21 TALOJA PHASE 2 PANVEL RAIGAD NAVI MUMBAI 410208 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410208 | L1 | Accepted-AOC Awarded as first lowest bidder L1 | |
| 2 | L2₹36.6 L+₹2.4 L (6.88%)Rejected-AOC | L2 | Rejected-AOC Second lowest bidder | |
| 3 | L3₹38.5 L+₹4.2 L (12.4%)Rejected-AOC 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L3 | Rejected-AOC Third lowest bidder | |
| 4 | L4₹38.6 L+₹4.4 L (12.8%)Rejected-AOC GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L4 | Rejected-AOC forth lowest bidder | |
| 5 | L5₹40.9 L+₹6.6 L (19.4%)Rejected-AOC | L5 | Rejected-AOC Fifth lowest bidder |
Tender Value
Refer Docs
EMD Value
₹87,861
Closing Date
15 Dec 2023, 6:00 pmClosed
GERD PASHAN PUNE
GERD PASHAN PUNE
SPECIAL REPAIR REPLACEMENT OF BER ACS AT ARDE AREA UNDER GERD PASHAN PUNE
2023_MES_628646_1
GERD/PSN/TOKEN/27 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹87,861
Yes
22 Feb 2024
17 Nov 2023
18 Dec 2023
17 Nov 2023
15 Dec 2023
1 Dec 2023
17 Nov 2023 - 24 Nov 2023
Amount
Dismantling/ taking down split/ window AC from site including its connection, indoor unit and outdoor unit with safety and deposited to MES storecomplete all as specified and directed.
Taking down existing old unserviceable submain wiring with all accessories of any size including making good to the disturbed surface complete all as directed.
Supply install, testing and commissioning of Energy rating BEE 5 star inverter Split Air condioning capacity of 1.5 TR with indoor and outdoor unit having comprising of the following (a) Multi stranded copper conductor wire 3 core 4 Sqmm with copper lugs not less than 3.0 mtrs (b) Incoming and outgoing quality copper pipe with foam insulation duly whiled taped of each size not less than 3.0 mtrs (c) Having 2 nos of bracket duly powder coated with anchor fasteners, nut, washers set 01 (d) Key features (i) Multi adjustable mode (ii) High ambient cooling (iii) Super dry (iv)Turbo cooling (v) ECO friendly Refrigerant R-32/ R-410A (vii) 100% Copper (viii) Sleep mode (ix) Wide Voltage range operation (x) The ISEER value of Air conditioner shall be 4.5 (minimum) (xi) Cordless remote-01 No.
Supply install, testing and commissioning of Energy rating BEE 5 star inverter Split Air condioning capacity of 2 TR with indoor and outdoor unit having comprising of the following (a) Multi stranded copper conductor wire 3 core 4 Sqmm with copper lugs not less than 3.0 mtrs (b) Incoming and outgoing quality copper pipe with foam insulation duly whiled taped of each size not less than 3.0 mtrs (c) Having 2 nos of bracket duly powder coated with anchor fasteners, nut, washers set 01 (d) Key features (i) Multi adjustable mode (ii) High ambient cooling (iii) Super dry (iv)Turbo cooling (v) ECO friendly Refrigerant R-32/ R-410A (vii) 100% Copper (viii) Sleep mode (ix) Wide Voltage range operation (x) The ISEER value of Air conditioner shall be 4.5 (minimum) (xi) Cordless remote-01 No.
Supply install, testing and commissioning of Energy rating BEE 3 star inverter Split Air condioning capacity of 3 TR with indoor and outdoor unit having comprising of the following (a) Multi stranded copper conductor wire 3 core 6 Sqmm with copper lugs not less than 3.0 mtrs (b) Incoming and outgoing quality copper pipe with foam insulation duly white taped of each size not less than 3.0 mtrs (c) Having 2 nos of bracket duly powder coated with anchor fasteners, nut, washers set 01 (d) Key features (i) Moisture Removal (*2.75 Litres/Hour) (ii) ECO friendly Refrigerant R-32/ R-410A (iii) Rated Voltage 230V, AC, 50 HZ (iv) The ISEER Value of Air conditioner shall be 3.6 (Minimum) (v) LCD Remote with display-01 No. Note: Serial item No 3 to 5 1. Extra copper pipe and multistranded copper conductor wire required for Air Conditioner to be installed on wall of building roof top shall deemed to be included in quoted rate. 2. Rate for Scafolding/Ladder/Tools and plants required to install Air conditioner i.e for making of holes to wall, drilling, making good distrubed surfaces and matching with the existing colour shall deemed to be included in quoted rate. 3. Outdoor unit should be kept above the level of indoor unit for installation of ground floor ACs outdoor should be on wall surfaces and for First floor ACs should be on parapet wall of Roof top of the building with out extra cost. 4. The MES Number be painted on indoor and Outdoorunit with navy blue colour letters of size not less than 15 mm height. Drain pipe from indoor unit to plinth protection of Outside the building. 5. The quoted rates are also inclusive of making holes in brick/stone wall for installation of Air Conditioner and make good to the existing surface with putty and paint complete all as specified and directed.
Meterial and Labour for sub main wiring with two single core 4 Sqmm FRLS PVC insulated stranded flexible copper conductor cable 660/1100 volts grade drawn in through rigid flexible non metalic PVC casing caping of suitable size with and including PVC insulated 4 Sqm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly, complete all as specified and directed Note : 1. Two runs of cable and one run of earth wire and one run of PVC casing Capping will be measured and paid as one unit.
Meterial and Labour for sub main wiring with two single core 6 Sqmm FRLS PVC insulated stranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible non metalic PVC casing caping with and including PVC insulated 6 Sqm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly, complete all as specified and directed Note : 1. Two runs of cable and one run of earth wire and one run of PVC casing Capping will be measured and paid as one unit.
Meterial and Labour for sub main wiring with two single core 10 Sqmm FRLS PVC insulated stranded flexible copper conductor cable 660/1100 volts grade down in through rigid flexible non metalic PVC casing caping with and including PVC insulated 6 Sqm single core single strand copper conductor as continuous earth wire in green colour connected to common earth dolly complete all as specified and directed. Note : 1. Two runs of cable and one run of earth wire and one run of PVC casing Capping will be measured and paid one unit.
Supply and Fix in repair of sheet Metal enclosure with socket plug top & MCB with a two pin and earth plug and socket complete with one single pole MCB SP 20A' to 32 Amp 'C Curve complete all as specified and directed.
Meterial Labour for brick work with fly ash bricks, straight or curved on plan exc 6meter mean radius, built in cement mortar 1:3 (for covering of opening) complete all as specified and directed.
Meterial and Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement 1:3 complete all as specified and directed.
Meterial and Labour for preparation newly plaster wall surface and applying3 coat of white washing complete complete all as specified and as directed.
Meterial and Labour for preparation new plasterd surface and applying 2 coat of oil bound distemper over a coat of primer complete all as specified and as directed
R K ENTERPRISES
SIYA ASSOCIATES
M/s Vijay Airconditioning Pvt Ltd
AISWARYA ENTERPRISES
somnath engineering corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .