Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹15.0 L+₹32,415 (2.21%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest | |
| 3 | L3₹15.0 L+₹33,930 (2.32%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical None CRITERIA FULL FIL AS PER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
10 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT
REPAIR/MAINTENANCE OF SUMMER COOLING APPLIANCES WITH ALLIED WORKS AT AF STN BKT
2021_MES_435998_1
8502
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) BKT
₹30,000
Yes
14 Jun 2021
13 Apr 2021
12 May 2021
13 Apr 2021
10 May 2021
27 Apr 2021
60 days
Amount
Disconnecting, cutting and taking out unserviceable sealed unit compressor of window type Air conditioner 1.5 Ton capacity any make & model and supply and fixing company new compressor of same make as existing for window type air condition 1.5 Ton capacity soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner at site and testing on load complete all as specified and directed by the Engr-in-Charge
All as per Item No 1 here in before but for split AC 1.5 Ton Capacity
All as per Item No 1 here in before but for split AC 2.0 Ton Capacity
All as per Item No 1 here in before but for Water cooler of storage capacity 40-80 ltr/ 60-120 Ltr
All as per Item No 1 here in before but for Water cooler of storage capacity 120/150 ltr
All as per Item No 1 here in before but for Refrigerator upto 195 Ltr
All as per Item No 1 here in before but for Refrigerator above 195 Ltr Note for Item No 1 to 7 :- (i) The unit ratequoted include for transportation of items to site of work & back as applicable (ii) Cost of refrigerant gas & oil deemed to be included in the unit rates quoted by the contractor
S&f Indoor blower motor of Split type AC 1.5 Ton capacity any make with super enameled copper winding, fixing and testing on load complete all as specified and directed by Engineer-in-Charge
S&f indoor blower motor of Split type AC 2Ton capacity any make with super enameled copper winding, fixing and testing on load complete all as specified and directed by Engineer-in-Charge
S&f blower motor of Water Cooler any capacity any make with super enameled copper winding, fixing and testing on load complete all as specified and directed by Engineer-in-Charge
Re-winding of blower motor of desert cooler any capacity any make with super enameled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement of gun metal bushes/bearing, fixing and testing on load complete all as specified and directed by Engineer-in-Charge
S&F Starting capacitor 80-100 mfd for window/Split type room air conditioner 1.5/2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
S&F Starting capacitor 100-120 mfd for window/Split type room air conditioner 1.5 /2 Ton capacity including taking out the old unserviceable capacitor complete all as specified and directed by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 13 here-in-before but 4 mfd
All as per Item No 13 here-in-before but 6 mfd
S&F Running capacitor 10 mfd for water cooler including taking out the old unserviceable capacitor complete all as specified and didfrected by Engineer-in-Charge Make : Epcos/Havells /Usha/ Tipcon
All as per Item No 16 here-in-before but 20 mfd
All as per Item No 16 here-in-before but 36 mfd
All as per Item No 16 here-in-before but 45 mfd
All as per Item No 16 here-in-before but 50+6 mfd
All as per Item No 16 here-in-before but 55+6 mfd
S&F Starting relay for 1.5 Ton window type AC including taking out the old unserviceable relay complete all as specified and directed by Engineer-in-Charge Make : Renutrol/indfoss
All as per Item No 22 here-in-before but for split type AC
All as per Item No 22 here-in-before but for water cooler
All as per Item No 22 here-in-before but for Refrigerator
S&F Thermostatic switches of any capacitysuitable for window/split type AC including taking out the old unserviceable switches complete all as specified and directed by Engineer-in-Charge Make : Renutrol/Indfoss
All as per Item No 26 here-in-before but for water cooler
All as per Item No 26 here-in-before but for Refrigerator
S&F MS front bottom panel of water cooler duly spray painted to match with the existing water cooler including dismantling/taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge
S&F Chromium plated drip tray assembly of water cooler complete with elbow including dismantling/taking out the old unserviceable drip tray complete all as specified and directed by Engineer-in-Charge
S&F Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for water cooler complete with two clamps (worm gear type) one on each side including dismantling the old unserviceable hose pipe complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia PVC pipe cotton bralded for water cooler connection complete all as specified and directed by Engineer-in-Charge
S&F 15 mm dia PVC (heavy duty) pipe for desert cooler complete all as specified and directed by Engineer-in-Charge
S&F 20 mm dia MS clamp (worm gear type) for PVC pipe including dismantling the old unserviceable clamp complete all as specified and directed by Engineer-in-Charge
S&F Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size including taking out the old unserviceable motor complete all as specified and directed by Engineer-in-Charge Make : AUE/Universal/Khatain/Bajaj
All as per Item No 35 above here-in-before but out door unit split type AC
All as per Item No 35 above here-in-before but for Water cooler
All as per Item No 35 above here-in-before but for Desert cooler 3 speed
S&F in repair Circuit board PCB of Split Type AC complete for 1.5/2.0 TR Split type A/C and complete testing as per directed
Repair and maintenance of Circuit board PCB complete for 1.5/2.0 TR Split type A/C and complete including testing all as specified and directed by Engineer-in-Charge
S&F Indoor unit of split type AC capacity 1.5 TR including evaporator coil ,blower ,blower motor,controling circuit of AC complete all as specified and directed by Engr-in Charge. Make- LG,Carrier ,Daikin ,Samsung
All as per Item No 41 here-in-before but for Capacity 2.0 TR
S&F Blower fan blade complete for desert cooler all as specified and directed by Engineer-in-Charge Make : AUE/Universal/Khaitan/Bajaj
S&F Cable PVC insulated sheathed 3 core copper conductor size 40/0.0076 mm including taking out the old unserviceable conductor complete all as specified and directed by Engineer-in-Charge
S&F Push cock press push type MS chromium plated suitable for 15 mm bore pipe for water cooler including dismantling the old unserviceable push cock complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing cleaning of window type room air conditioner 1.5 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Note:-Replacement of spare or gas shall be measured and paid separely under respective item
Maintenance, servicing cleaning of split type air conditioner 1.5/2 Ton capacity at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condensor motor, blower/condensor fan rectification of fault, connecting and testing on load. Note:-Replacement of spare or gas shall be measured and paid separely under respective item
S&F Regulating knobs of window type room air conditioner including dismantling the old unserviceable knobs complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing & repair of refrigerator 170/195 ltrs capacity any make model cleaning the various components and replacement i. e Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Blub Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge
Maintenance, servicing & repair of refrigerator 310/345 ltrs capacity of any make model, cleaning the various components and replacement of unserviceable items like Chill tray, Shelves, Freezer door, Door Gasket, Door Lock, Bulb Holder & bulb and Food tray complete all as specified and directed by Engineer-in-Charge
S&F Defrost timer for domestic refrigerator including dismantling the old unserviceable timer all as sample and directed by Engineer-in-Charge Make : Samsung/Godrej/Whirpool
All as per Item No 50 here-in-before but Bimetal relay
All as per Item No 50 here-in-before but Defrost heater
All as per Item No 50 here-in-before but Fan motor assy alongwith fan blade
All as per Item No 50 here-in-before but over load proection for refrigerator
All as per Item No 50 here-in-before but PTC relay
S&F Condenser line filter for window/split AC complete all as specified and directed by Engineer-in-Charge
S&F Condenser line filter for Refrigerator complete all as specified and directed by Engineer-in-Charge
S&F Condenser line filter for Water cooler complete all as specified and directed by Engineer-in-Charge
Maintenance & servicing of water cooler 40/80 ltrs,60/120 & 120/150 Ltrs at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condensor motor, blower fan, rectification of fault, replacement of spare and charging of gas as on required basis, connecting & testing on load for performance all as directed by Engineer-In-Charge Note : Cost of Spares and gas shall be measured and paid separately
Spray painting to water cooler 40/80 Ltrs & 120/150 Ltrs with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint all as per specified and directed by Engineer-in-Charge
Taking out the existing rusted/worn out base plate of water cooler 40/80 ltrs & 120/150 Ltrs capacity by disconnecting the compressor, condenser motor, providing new MS base plate including welding work and straightening of base plate & re-fixing the compressor, condensor & condenser motor making all connection, charging gas and testing on load all as specified and directed by Engineer-in-Charge
S&F Grill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site including dismantling old grill complete all as specified and directed by Engineer-in-Charge
Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparation of surfacse with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling the pump & motor complete all as specified and directed by Engineer-in-Charge (a) Wiper (b) Plastic impeller of tullu pump with enclosure (c) Distributor
Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new condensing unit of exsting size model in place including welding, brazing etc and testing on load all as specified and directed by Engineer-in-Charge
All as per item No 65 here-in-before but evaporator coil
All as per item No 65 here-in-before but condensing unit of water cooler
Spray painting of window type AC 1.5 Ton capacity including preparation of old surfaces and applying one coat of synthetic enamel paint (colour as per original shade ) including writing of SM No over the body with white/black paint all as directed by the Engineer-in-Charge
Supply and replace air filter suitable for window type AC 1.5 Ton capacity all as per sample and directed by Engineer-in-Charge
All as per Item No 69 here-in-before but for split type AC
Supply and replace Submersible pump for desert cooler for lifting water upto 1.2 meter head. Make : Champian/Crompton Greaves/Meghdoot/Usha.
S&F Wood wool pad set suitable for desert cooler heavyy duty including dismantling the old unserviceable wood wool pad set all as directed by Engineer-in-Charge
Re-winding of main transformer of voltage stabilizer capacity 5 KVA with super enameled copper winding wire of suitable gauge including making connection by soldering and testing complete all as directed by Engineer-in-Charge
All as per Item No 73 here-in-before but 4 KVA
S&F Relay for voltage stabilizer 240 volts all as per sample and required at site including dismantling the old unserviceable relay
S&F Volt meter 0-300 volts
S&F Ampere meter 0-30 Amp
S&F Timer circuit for voltage stabilizer including dismantling the old unserviceable timer circuit all as per sample and required at site complete all as specified and directed by Engineer-in-Charge
S&F Connector porcelain type for voltage stabilizer including dismantling the old unserviceable porcelain complete all as specified and directed by Engineer-in-Charge
S&F Float valve with PVC float ball brass stem & fly nut complete with screwed for iron pipe 15 mm bore fixed in repairs complete all as specified and directed by Engineer-in-Charge
S&F Gun metal gate valve with iron wheel head screwed both ends for iron pipe 15 mm dia fixed in repairs complete all as specified and directed by Engineer-in-Charge Make : Neta/Leader/Bir
S&F 15 mm dia PVC connection to water coolers 450 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge
S&F GI nipple 15 mm dia 150 mm long fixed in repair complete all as specified and directed by Engineer-in-Charge
S&F 15 mm bore GI tubing medium grade fixed in repair complete all as specified and directed by Engineer-in-Charge
S&F GI Union 15 mm dia fixed in repairs
S&F GI Socket 15 mm dia fixed in repairs
Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Mettalic) complete with one single pole MCB for 240 volts 20 Amps rating rupturning capacity 10 KA complete fixed as in repairs complete all as specified and directed by Engineer-in-Charge Make Havells/MDS/Legrand
Taking down unserviceable split AC and re-fixed to its original position after repairing including welding and brazing of copper pipe complete all as specified and directed by Engineer-in-Charge Note : Filling of gas shall be measured be paid for separately
Supply and fixing of Copper Pipe size 5/8"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 1/4"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 1/2"( with sleeves)including welding brazing of copper pipe
Supply and fixing of Copper Pipe size 3/8"( with sleeves)including welding brazing of copper pipe
S&F insulation for copper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split AC complete all as specified and directed by Engr-In-Charge.
Supply and fixing of Blower assembly for split type AC any capacity
Supply and fixing of condenser fan suitable for Window type AC any capacity
Supply and fixing of condenser Fan Suitable for Split Type AC any capacity
Supply and fixing of Top Plug 3 pin 220 Volt 5 Amp Make :- Anchor/Plaza/Havells
Supply and fixing of Top Plug 3 pin 220 Volt 15 Amp Make :- Anchor/Plaza/Havells
S&F Industrial protected socket with cap and chain 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
S&F Industrial protected plug top 3 pin 240 volt 20 Amp Make :-Anchor/Plaza/Havells
Supply and fix blower for split AC 1.5 Ton capacity for indoor unit
Supply and fix blower for split AC 2 Ton capacity for indoor unit
M&L for repair to remote circuit complete with remote device for 1.5/2 TR window/split type AC and complete testing as per directed
S&F in repair MCB protected socket combination including MCB of capacity 25 amps withsteel sheet/plastic enclosure with plug topAC 230 V complete all as specified and directed
S&F in repair MCB single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as directed.
S&F Cable PVC insulated sheathed 3 core copper conductor size 70/0.0076 mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge
S&F Cable PVC insulated sheathed 3 core copper conductor size 110/0.0076mm including taking out the old unservidceable conductor complete all as specified and directed by Engineer-in-Charge
M&L for charging of refrigerant gas (R-22 /32/ 134 (a) / 410 c ) in split/window type AC after detecting leakage test with CO2 gas with provision of all T&P as required at site complete all as specified and directed by Engineer-in-Charge.
All as per item no. 109 here in before but for water cooler
All as per item no. 109 here in before but for refrigerator
M/S WALIA TRADESRS
H C CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .