Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance III A 28 GF VAISHALI GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
₹14.8 L
Closing Date
12 Nov 2021, 3:00 pmClosed
Executive Engineer (Electrical)-I
Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
SITC of VRF and Cassette AC Unit in HUSS and UG Section Office (including AMC) at IIT Delhi
2021_IIT_655761_1
IITD/WORKS(SP- 3686)/2021
Open Tender
Miscellaneous Works
Works
45 days
INDIAN INSTITUTE OF TECHNOLOGY DELHI
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
Exempted
10 Dec 2021
2 Nov 2021
15 Nov 2021
2 Nov 2021
12 Nov 2021
2 Nov 2021
Amount
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based controller, top / side discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 Degree C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions at 50% load shall not be less than 7 and IEER not less than 6.5. (Acceptable make: Blue Star / LG / Daikin / Hitachi / Carrier / O-General / Mitsubishi / Toshiba) Location: HUSS Faculty Chambers, MS Bldg. 6th Floor.
For HUSS Faculty Offices
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +/- 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 Degree C WB temperature. (Make of Indoor units shall be same as main outdoor unit) Cutting and mending good of existing false ceiling shall be done by the contractor during installation of ceiling mounted indoor unit. New batteries for remotes shall be provided by the contractor initially.
Supply, Installation, testing and commissioning including vaccumisation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, Y-type joints wherever required, with adjustable with ring type hanger supports, jointing / brazing including accessories, insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required: NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe
6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply Installation, Testing & Commissioning of 4 Ton (not less than 48000 BTU/Hr) Inverter Cassette AC comprising air cooled Outdoor units suitable for cooling, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based controller, top / side discharge type condensing unit(s), with R 410 A refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The unit shall be complete with 4-way flow Cassette Type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control (with batteries) etc., suitable for operation on single phase 230 V +/- 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions (return air) of 27 degree C DB and 19 Degree C WB temperature. Cutting and mending good of existing false ceiling shall be done by the contractor during installation of ceiling mounted indoor unit. Location: LHC UG Section (Acceptable make of AC: Blue Star / LG / Daikin / Hitachi / Carrier / O-General / Mitsubishi / Toshiba)
Supply, Installation, testing and commissioning including vaccumisation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for Cassette type AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required:
15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including GI protective sheet covering outside the room as required. (Only for outdoor portion)
300 mm width x 50 mm depth x 1.6 mm thickness
Supplying and laying of ISI marked CPVC pipe of 32 mm dia for draining of sweated water from AC evaporator unit including providing tee, joints, elbows, supports, etc. insulated with XLPE class - O tubular insulation / with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick etc. complete as required.
Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. C-channel of size 100 mm x 50 mm x 6 mm (thick) for resting the condenser unit on the roof / floor of the building duly supported from the bottom as required including painting the framework etc. complete as required.
Supplying and laying of ISI marked FRLS industrial flexible copper cable of size 2 core x 1.5 sqmm of 1.1 kv grade conforming to IS694:2010 including making connection etc. for communication between indoor and outdoor unit and other units, etc. through conduit complete as required. (for communication) (Acceptable make: Polycab / Havells / Gloster / RR Kabel / Nicco / Skytone / Finolex / KEI / Universal / Anchor)
Supplying and laying of following size FRLS industrial flexible copper conductor cable of 1.1 kV grade conforming to IS694:2010 of following sizes including making connections etc. as required. (Acceptable make: Polycab / Havells / Gloster / RR Kabel / Nicco / Skytone / Finolex / KEI / Universal / Anchor)
3 core x 2.5 sqmm (LHC & UG both)
4 core x 6 sqmm (UG)
4 core x 16 sqmm (HUSS)
Supplying and making end termination with brass compression gland and tinned copper lugs for following size of pvc insulated and pvc sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
4 core x 6 sqmm (UG)
4 core x 16 sqmm (HUSS)
Providing and fixing 8 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Supplying and fixing SP / DP sheet steel enclosure on surface / recess with 5/6 A, 240 V, C-curve SP MCB complete with connections, testing and commissioning etc. as required. (Acceptable make: Havells / Standard / BCH / Legrand / Anchor / Orient / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc as required. (but without MCB/RCCB/Isolator): 2 + 12 Way, double door (Acceptable make: Havells / Standard / BCH / Legrand / Anchor / Orient / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Acceptable make: Havells / Standard / BCH / Legrand / Anchor / Orient / L&T / Polycab / C&S / ABB / Siemens / Schneider)
Single Pole
Double pole (as incomer to DB)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in sheet steel enclosure including drilling holes, duly factory painted as required, making connections, etc. as required. : 100 A, FPMCCB (Acceptable make: Havells / Standard / BCH / Legrand / Anchor / Orient / L&T / Polycab / C&S / ABB / Siemens / Schneider) For main power connection.
Supplying and fixing of weather proof non-metallic 4P enclosure on surface / recess with 16/25/32 amp, 415 V, "C" curve Four Pole MCB with IP-65 rating complete with connections, testing and commissioning as required. (Reference similar product: Legrand 4 Module Plexo Box for MCB, IP-65) - For outdoor units (Acceptable Make: ABB / Legrand / L&T / Havells / Anchor / Finolex) - For outdoor unit
SUB HEAD - 2 (AMC) (Supplementary agreement shall be formed) under ARMO Fund
Comprehensive (Routine, Preventive and Breakdown) maintenance of 14 HP VRF/VRV AC unit & 1 x 04 TR Cassette Type AC including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units during the defect liability period of 1 year after date of commissioning as per maintenance schedule. (Completely free of cost): 1st Year
Comprehensive (Routine, Preventive and Breakdown) maintenance of 14 HP VRF/VRV AC unit & 1 x 04 TR Cassette Type AC including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units after defect liability period of 1 year from the date of commissioning as per maintenance schedule. Any breakdown shall be attended within 4 hours of reporting. Spare parts required during breakdown maintenance shall be arranged and replaced by the Contractor. This is applicable for the whole system of AC units installed. (N.B.: 01 Job means during a period of one year)
2nd year
3rd year
4th year
5th year
6th year
TRANSCEND CONTRACTS PVT. LTD.
M/S COOLREF ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .