Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.7 L+₹76,784.50 (3.51%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance L2 | |
| 3 | L3₹24.6 L+₹2.7 L (12.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹24.8 L+₹2.9 L (13.3%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance L4 | |
| 5 | L5₹24.8 L+₹2.9 L (13.4%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L5 | Rejected-Finance L5 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
11 Jan 2020, 10:00 amClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARGH (DIST), ASSAM
ADDN/ALTN TO LED STREET LIGHT SYSTEM INCLUDING CERTAIN REVENUE/MINOR WORKS AT DINJAN UNDER GE DINJAN
2019_MES_308178_1
C/8924/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹49,000
Yes
5 Mar 2020
20 Dec 2019
13 Jan 2020
20 Dec 2019
11 Jan 2020
5 Jan 2020
Amount
Taking down the existing street light fittings of any capacity and pipe bracket carefully from electric pole by any means and keeping in stock for refixing at the place directed by Engr-in-Charge complete all as specified. (Note:-Refixing of lights shall be measured and paid separately under relavent items. The deteriorated bracket will be under schedule of credit . Rates quoted shall be incl of arrangements for climbing poles/ heights for fixing and removing etc)
Material and labour for street light bracket of 50mm GI Pipe light grade with end of the pipe welded with GI nipple of suitable size to accomodate the light fitting for fixing two street light fiittings in two different angles to set the lux level on the bottom. Length of the bracket should not be less than 1.5 mtr including fixing accessories like clamps, nuts, bolts etc suitable for both RCC poles and Steel tubular poles complete all as specified and directed.Note :- Angle ,design & type of bracket will be directed by the Engr-in-charge.
S&F street light bracket arm of length not less than 1.0Mtr made out of GI tubing 32mm light grade fixed to pole etc with suitable size flat iron clamp nuts, bolts complete all as specified and directed.
Fixing only LED street light fitting of any size and capacity which is obtained from ser No. 01 with suitable fixing arrangements including twin core aluminum cable of 2.5 Sqmm as required complete all as specified and directed.
Supply and fixing new LED street light fitting of capacity 90W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection, with twin core aluminum cable of 2.5 Sqmm as required in existing location. Make Havells Endura cityliner Neo SL 90 W LED757SASYBOTG or Crompton LSTP-90-CDL or equivalant in Everyday/Jaquar/Phillips (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor)
Supply and fixing new LED street light fitting of capacity 100W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location. Make : Havells Endura cityliner Neo SL 100W LED757SASYBOTG or Crompton LSTP-100-CDL or equivalant in Everyday/Jaquar/Phillips (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor) (Necessary excavation, PCC wk, Bracket, Connecting wire will be measured and paid separately under relavent items)
Supply and fixing LED bollard of capacity 09 W including with necessary fixing accessories like nuts& bolts for holding the bollard fitting. Bollard fitting to be fixed with nuts and bolts by grouting the bolts in PCC including PVC bends of size 25mm and connector to be provided inside the PCC for passing out the in and out cables with suitable PVC junction box and connector to be provided for incoming and outgoing of UG cable passing through each fitting and connecting the bollard with twin core aluminium cable complete all as specified and directed. Make: Crompton LBLA1-10-CDL / Havells BambooBL8WLED857SSYMTOPC or equivalant in Jaquar/Eveready. Note :- a. PCC & Aluminum twin core cable will be measured and paid separatle b. PVC bend, nuts and bolts and other connecting accessories to be included in the quoted rate.
S & F 30W of size 2 ft X 2ft white powder coated CRCA full glow recess mounting LED backlit panel (warm white) including all cutting arrangement in ceiling all as specified and directed by Engr-in-Charge. Make : Havells VENUS NEOHE2X2PLR 18-42WLED865MOD or Crompton LCTLRN 30-FO-CDL or equivalent in Jaquar, Eveready.
S & F Trim LED panel round Aesthetically designed recessed mounted panel in a light weight plastic body 15 W LED (warm white) ceiling cutout dia 140 mm, height 27mm all as sepcified and directed by Engr-in-Charge. Make: Havells cat No LHEBLDP7IN1W015 or equivalent in Crompton, Eveready, Jaquar.
S & F Trim LED panel round Aesthetically designed recessed mounted panel in a light weight plastic body 5 W LED (warm white), Ceiling cutout dia 75mm. Height 22 mm all as sepcified and directed by Engr-in-Charge. Make: Havells cat No LHEBLDP7IN1W005 or equivalent in Crompton, Eveready, Jaquar.
Supply and fixing new LED street light fitting of capacity 80W, with pressure die cast housing , toughned glass and individual LEDs with secondary optics and IP 66 protection, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and twin core aluminum cable of 2.5 Sqmm as required in existing location. Make : Havells Endura pearl plus SL80WLED757SASYTOPC or Equivalant in Everyday/Jaquar/Phillips (Warrenty on Driver, LEDs and PCB for 5 Years to be submitted by the contractor)(Necessary excavation, PCC wk, Bracket, Connecting wire will be measured and paid separately under relavent items)
Supply and laying cable UG XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) 1100 volts grade with stranded aluminiumconductor of size 70 sqmm 3.5 core complete all as specified and as directed
All as per item No 12 above but of size 50sqmm 3.5 dia bore complete all as specified and directed.
M&L LT Cables from post top lantern to LT Panel , Supply and lay LT UG Cable between post top lantern to LT Panel of size 4c x 10sq.mm XLPE Insulated, armoured heavy duty electric cables with aluminium conductor 1100volts including aluminum lugs for connecting complete all as specified and directed.
M&L LT Cables from post top lantern to LT Panel , Supply and lay LT UG Cable between post top lantern to LT Panel of size 2c x4sq.mm XLPE Insulated, armoured heavy duty electric cables with aluminium conductor 1100volts including aluminum lugs for connecting complete all as specified and directed. .
Excavation in trenches not exceeding 1.5 Mtrs. wide and not exceeding 1.5 Mtrs. in depth for foundation, laying of cablesetc and getting out in hard/dense soil complete all as specified.
Excavation in trenches exceeding 1.5 mtr wide and not exceeding 3 mtr depth (beyond the first 1.5 Meter ) for foundation of poles etc not exc 10 Sqm in plan and getting out in soft /loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm depth in soil.
Removing excavated material (Soil) n.exc 50 m and depositing where directed at a level n. exc 1.5 Mtrs. above the starting point complete all as specified.
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed.
Supply and laying well burnt bricks sub class B bricks laid breath wise along length of cable in trenches for cable protection
M & L for plain cement concrete (1:2:4) type B-1 ( with using 20 mm graded stone aggregate) as in coping necessary form work and finishing the exposed plaster in CM (1:3), 5mm thick & finished even & smooth without using extra cement complete all as specifed and directed.
Material and labour for Weather proof flat twincore cable of 2.5 Sqmm for connecting of light fittings complete all specified and diredcted.
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through PVC casing-caping complete all as directed by Engr-in-Charge. (Note :- PVC Conduit shall be included in same rate)
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC casing caping complete all as directed by Engr-in-Charge. (Note :- PVC casing- caping shall be included in same rate).
M & L for point wiring with 2.5 Sqmm (nominal area) , PVC insulated, multistranded, single core, unsheathed, copper conductor cables draw through and including PVC casing caping with all fitting and accessories of PVC Casing caping (like Tee bend etc) complete fixed to Wall /Ceiling etc with and including 2.50 Sqmm (nominal area) PVC insulated unsheathed , stranded , single core, copper cable green in colour as in earth continuity wire connecting to common earth point including PVC termial board for mountining of Switch Socket Combination of 15 Amps on independent board.
S & F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S&F Switch piano type 15 Amp one way complete all as specified and directed..
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 380 mm sweep 1 phase 1400 RPM all as specified and directed. Make : Crompton Model No EXHD380-4-1
M & L for cutting/making hole for fixing of exhaust fan as per size and making good disturbed surface with existing surface all as specified and directed by Engr-in-charge.
S&F, testing and commissioning of Refrigerator electric driven, single phase of capacity 195 ltr BEE 5 star rated complete all as specified and directed. Make : Voltas Tushar/Blue Star/Godrej.
S&F metal plug and socket with MCB and steel enclosure 20 Amp, SPN MCB metalic P&S complete all as specified and directed.
S&F only for auto voltage stabilizer, single phase naturally air cooled indoor type & designed for input with time delay system of input 140 to 280 volt and output 230 V with accuracy of +/- 2% variation, 240 volt, capacity 2KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 01 KVA and all as specified.
S & F Water heater storage type, electric supplied and installed complete capacity 25 litres including all fixing accerroies with TOP PULG of 15 Amp. Make : HAVELLS Model No Senzo GHWASESWH025
S&F Cromium Plated Connection pipe 15mm dia,450mm long,with Hexagonal Nut and Washer fitted at both end for carrying Hot Water.
S&F PVC Connection pipe 15mm dia,450mm long,with Hexagonal Nut and Washer fitted at both end for carrying Cold Water complete all as specified and directed.
S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrul and fixed for 15mm bore dia.
S&F gun metal, globe or gate valves, 15mm dia with iron wheel head, screwed both ends for iron pipe and fixed.
S&F galvanised tube meadium grade 15mm dia with all fitting,laid in trench/wall complete all as specified and directed.
Dismantling of ACSR conductors from poles of any size & capacity and serviceable materials keep in safe custody for re-sue and unservicable materials removing from the site complete all as specified and as directed
S&F out door panel weather & vermin proof including painting and treatment of height 60cm x Brdth 50cm x length 50cm box type with locking arraangement and AL busbar with RYB and neutral insulated sleeves of suitable size of cap 200 Amps and neutral of 100 Amps for connecting LT UG Cable incl necessary nuts, bolts connected accessories , din rail to accomodate MCB SP10A with necessary fixing arrangements & terminals for connecting the conductor of 70 / 50 sqmm XLPE Cableswith suitable foundation for fixing complete all as specified and as directed (Rates including of MCB SP an and BUS Bar)
Supply & fix single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified.
Supply & fix aluminium strip 25mm X 3.15mm complete with saddles & fixing screws for roof conductors/down conductors complete all as specified.
Supply & install GI Strip 32 X 6mm burried in ground for earth continuity from earth electrode to test point terminal block complete all as specified
S & F 40 mm bore, steel tubes, galvanised, light grade with all fittings and fixtures complete fixed to walls, ceilings and fixing for air termination rod etc complete all as specified and directed.
S & F test point terminal block made of gun metal of phosphor bronze of size 75mm X 75mm X 25 mm drilled & screwed including 3 Nos 8mm dia 25mm long hexogonal head screw of brass fixed to wall complete all as specified.
M&L for Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in ground preferably vertically in ground with top edge not less than 1.25 mtr deep below normal ground level connected with and including galvanised iron 32x6mm as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size, charcoal and salt in alternate layers necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 2 of SSR part-I and testing on completion complete all as specified and as directed.
Supply, installation, commissioning of Water cooler partially stainlesssteel, electric driven single phase having approx storage capacity of 80 litre and nominal cooling capacity of 40Litres per hour Complete all as specified and directed.
M&L switch socket combination 2-in-1, 5/16 Amps, 5 in 1, flush type, independent including PVC rectangular BOX and all as specified.
S & F stop valve, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15mm bore complete all as specified and directed.
M& L for plain cement concrete 1:3:6 type C2 (using 40mm gradede stone aggregate ) as in foundation filling and mass concrete etc complete all as specified and directed.
Supply and fix PVC junction box/loop in and out box, out door type,door duly hinged and opeanble type IP-65 with busbar and din rail to accommodate MCB SP 0f 6 Amps 'B" Series complete all as specified and directed. Make - Hansel/ Sintex
Material and labour for steel tubular swaged poles complete with cast iron base plate final taper plug bolts nuts & screws as specified 410 SP-31 (9.0 meter long) including two coats of aluminium paint over a coat of primer except the planing depth which shall be apinted with black bituminious paint including writing pole number using suitable paint complete all as specified and directed (Note : Excavation and earth work PCC filling shall be measured and paid separatley)
M/s HALDER ENTERPRISE
M/s GANDHESWAR PHUKAN
M/s PRABIR ENTERPRISE
M/S A K BROTHERS
FREEZCON
M/S S. P. ENTERPRISE
STANDARD ELECTRIC WINDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .