| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest. | |
| 2 | L2₹33.9 L+₹9,652 (0.29%)Rejected-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Being other than lowest. | |
| 3 | Rejected-Technical | - | Rejected-Technical not enlisted in requisite category c(vi) | |
| 4 | Rejected-Technical 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical not enlisted in requisite category c(vi) |
| Sl No | Description | Qty | Unit | shanti enterprises L1 | Tropical Refrigeration L2 |
|---|---|---|---|---|---|
| 1.00 | Supply & fixing Air termination rod, single pointed, copper rod 12mm dia and 300mm long complete all as specified & directed | 6 | Each | 7,000 ₹42,000 | 1,100 ₹6,600 Lowest |
| 2.00 | Supply & fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed | 2 | Each | 7,500 ₹15,000 | 1,200 ₹2,400 Lowest |
| 3.00 | M&L for copper strip of size 20x3.15mm fixed on epoxy earth strip insulator of size 25x3.15mm including fixing screws and fasteners for roof conductors and down conductors above ground level and fixing complete all as specified and directed. | 50 | RM | 650 ₹32,500 Lowest | 650 ₹32,500 Lowest |
| 4.00 | Supply & fixing Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead, by means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified & directed .
Notes:Quoted rates shall be deemed to be included the following
(a) Excavation ,RFR earth work in any type of soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, pre cast RCC cover 40 mm thick in PCC 1:2:4 type B-1, with suitable handle reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm.
(c) funnel with wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed.
(d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified & directed.
(e) Requisite quantity of common salt and charcoal in alternative layers as specified. | 2 | Each | 70,000 ₹1,40,000 | 35,000 ₹70,000 Lowest |
| 5.00 | Supply and fix fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detectors all as specified and directed by Engr-In-Charge.
Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Note: (i) Control panel shall be of intelligent, individual device addressable type to identify the fault of particular device capable to serve through manual call points installed at each bldg/segment.
(ii) There should be programmable inputs, key switch and key pad access, investigation delay period access.
(iii) Fire alarm control panel should be equiped with battery backup upto 4 hrs operation. | 1 | Each Set | 72,500 ₹72,500 Lowest | 1,20,000 ₹1,20,000 |
| 6.00 | Supply and fix addressable type multisensor detector with heat and smoke combination all as specified and directed.
Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. | 5 | Each | 6,500 ₹32,500 Lowest | 6,500 ₹32,500 Lowest |
| 7.00 | S&F addressable control module (remote switching device) one input one output type for operating of sounder/siren, detectors and sensors connecting with main control panel board and testing all as specified and directed.
Note: Operating voltage of the control module shall be as per existing only.
Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. | 1 | Each | 5,200 ₹5,200 Lowest | 5,200 ₹5,200 Lowest |
| 8.00 | Supply and fix Addressable electronic sounder cum strobe all as specified and directed by Engr-In-Charge.
Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. | 1 | Each | 11,200 ₹11,200 Lowest | 11,200 ₹11,200 Lowest |
| 9.00 | Supply and fix Addressable manual call point re-settable type with alarm LED complete all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. | 2 | Each | 6,200 ₹12,400 Lowest | 6,200 ₹12,400 Lowest |
| 10.00 | Supply and fix Remote Response indicator unit complete all as specified and directed by Engr-In-Charge.
Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. | 5 | Each | 280 ₹1,400 Lowest | 280 ₹1,400 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
23 May 2025, 6:00 pmClosed
GE (I) 866 EWS CARNICOBAR
GE (I) 866 EWS CARNICOBAR PIN-913866 C/O 99APO
SPECIAL REPAIR REPLACEMENT OF THE SMOKE DETECTION FIRE ALARM SYSTEM AND CONNECTED WORKS AT 122 HF COMPLEX LOGISTICS SECTION AFNET BLDG AND 151 SQN AND CERTAIN MINOR WORKS AT AF STN CARNICOBAR.
2024_MES_680209_3
8702/E8
Open Tender
Civil Works
Item Rate
180 days
CARNICOBAR AIR FORCE STATION
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) 866 EWS
₹70,000
Yes
21 Aug 2025
2 May 2025
30 May 2025
2 May 2025
23 May 2025
9 May 2025
Amount
Supply & fixing Air termination rod, single pointed, copper rod 12mm dia and 300mm long complete all as specified & directed
Supply & fixing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified & directed
M&L for copper strip of size 20x3.15mm fixed on epoxy earth strip insulator of size 25x3.15mm including fixing screws and fasteners for roof conductors and down conductors above ground level and fixing complete all as specified and directed.
Supply & fixing Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead, by means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified & directed . Notes:Quoted rates shall be deemed to be included the following (a) Excavation ,RFR earth work in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1, pre cast RCC cover 40 mm thick in PCC 1:2:4 type B-1, with suitable handle reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm. (c) funnel with wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed. (d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified & directed. (e) Requisite quantity of common salt and charcoal in alternative layers as specified.
Supply and fix fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detectors all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. Note: (i) Control panel shall be of intelligent, individual device addressable type to identify the fault of particular device capable to serve through manual call points installed at each bldg/segment. (ii) There should be programmable inputs, key switch and key pad access, investigation delay period access. (iii) Fire alarm control panel should be equiped with battery backup upto 4 hrs operation.
Supply and fix addressable type multisensor detector with heat and smoke combination all as specified and directed. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
S&F addressable control module (remote switching device) one input one output type for operating of sounder/siren, detectors and sensors connecting with main control panel board and testing all as specified and directed. Note: Operating voltage of the control module shall be as per existing only. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix Addressable electronic sounder cum strobe all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix Addressable manual call point re-settable type with alarm LED complete all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix Remote Response indicator unit complete all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
S&F Fire alarm sounder/sirens electronic type horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 Db to 120 Db measured at 1.5 mtr with sound output variation of + 5 DB 1500 mtr range with complete connections and all accessories including testing all as specified and as directed by Engineer-in-Charge
M & L for point wiring on wall/roof/ceiling surface with FRLS single core , multistranded PVC insulated copper conductor cable 1100 volts grade size 1.5 sqmm drawn through and including 20mm dia heavy duty rigid non metalic PVC conduit and conduit accessories along with one single core PVC insulated unsheated FRLS 1100 v size 1.5sqmm multistranded copper conductor as earth coninuity wire and connected to earth dolly for fixing of modular flush box, fixed with brass scres and cap washers for 5 Amps switch socket outlet point on independent board controlled by one number one way switch complete all as specified and directed.(Note - Accessories like modular PVC boxes, inner & outer cover plates shall be measured and paid seperately under respective items of BOQ)
S & F modular socket 2/3 pin combined 5 amps two module size all as specified and as directed by Engineer-in-Charge
S & F modular switch single pole 5 amps one module size all as specified and as directed by Engineer-in-Charge
S&F modular flux box 4 module size all as specified and as directed by Engineer-in-Charge
M&L for submain wiring with single core ,2 Runs of 2.5 sqmm nominal cross sectional area, FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing through & including suitable dia. PVC conduit and its fittings complete on surface/concealed along with 1 run of 2.5 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth continuty conductor complete all as specified and directed. Note: 3 runs of PVC cable and one run of PVC conduit shall be measured as one unit length.
-ditto- all as per Item No 17.00 here in before but using 1.5 sqmm nominal cross sectional area, FRLS multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade
Earthing complete with GI earth plate electrode 600x 600 x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m below ground level with the top edge not less than 1.5 m below ground level connected with GI earth wire of 4 sqmm by means of bolts, nuts, check nuts and washers as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified & directed . Notes:Quoted rates shall be deemed to be included the following (a) Excavation ,RFR earth work in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1, pre cast RCC cover 40 mm thick in PCC 1:2:4 type B-1, with suitable handle reinforced with welded steel wire fabric weighing not less than 1.87 kg/sqm. (c) funnel with wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed. (d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified & directed. (e) Requisite quantity of common salt and charcoal in alternative layers as specified.
M&L for 4mm dia galvanised iron or steel wire as in earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in PVC conduit/pipe or fixed to poles or DB's/Indoor type LT PBs or any other indicated situation for loop earthing etc. all as specified and directed.
Supply and fix in replacement of fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detector including taking down old unserviceable one all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent. Note: (i) Control panel shall be of intelligent, individual device addressable type to identify the fault of particular device capable to serve through manual call points installed at each bldg/segment. (ii) There should be programmable inputs, key switch and key pad access, investigation delay period access. (iii) Fire alarm control panel should be equiped with battery backup upto 4 hrs operation.
Supply and fix in replacement addressable type multisensor detector with heat and smoke combination all as specified and directed. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
S&F in replacement addressable control module (remote switching device) one input one output type for operating of sounder/siren, detectors and sensors connecting with main control panel board and testing all as specified and directed. Note: Operating voltage of the control module shall be as per existing only. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix in replacement Addressable electronic sounder cum strobe all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix in replacement Addressable manual call point re-settable type with alarm LED complete all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
Supply and fix in replaement Remote Response indicator unit complete all as specified and directed by Engr-In-Charge. Make- Honeywell/Esser/Schneider/Siemens/Agni/GST or equivalent.
M&L for submain wiring comprising single core , 2 Runs of 1.5 sqmm nominal cross sectional area,FRLS-H multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in PVC casing capping/ conduit and its fittings complete on surface/concealed along with 1 run of 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth continuity conductor complete incl taking down old UNSV sub main wiring all as specified and directed. Note: 3 runs of PVC cable and one run of PVC conduit/ casing capping shall be measured as one unit length.
All as per Ser No 27.00 here in before but using 2.5 sqmm nominal cross sectional area,FRLS-H multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade
S&F rigid non-metallic PVC conduit pipe 20mm dia including all tees, bends, elbows, bell mouth, reducers etc and all fixing accessories on wall such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engr-In-Charge.
All as per Ser No 29.00 here in before but of dia 25mm all as specified and directed by Engr-In-Charge.
S&F Switch socket combination 2 in 1 , 3 pin, 5 and 15 amps socket complete all as specified and directed by Engr-In-Charge.
S&F in replacement yard hydrant post 80mm dia MS flanged type 1.5m height including all necessary fittings, hangars, fasteners, tees etc and testing complete all as specified and as directed.
M&l for Preparation of old untreated/ new surface of pipes any description n.exc 60 cm girth including holder bats, distance pieces etc (length measured over bends, branches etc), priming with 2 coats of red oxide zinc chrome primer and painting of synthetic enamel paint (ordinary tint) x 2 coats complete all as specified and directed by Engr-in-Charge. Note: Not reachable portion/bottom side of pipeline shall be dismantled and then re-fitted at its position after completion of primer and painting without any extra cost.
S&F in replacement hydrant valve single headed made up of brass body complete suitable to fix in 80mm hydrant post including flange, wheel, lid and accessories all as specified and directed by Engr-In-Charge.
S&F in replacement Butterfly valve size 80 mm dia including taking down complete all as specified and directed.
S&F in replacement of strainer with CI foot valve for suction of 100mm dia all as specified and directed by Engr-In-Charge.
S&F in replacement of MS ERW pipe 80mm dia all as specified and directed by Engr-In-Charge. . Note: Pipeline needs to replaced inside the RCC duct of average depth 75cm and width 60cm.
M&L for cutting of bushes and grass around the underground RCC Static Water Tank including removing from site, preparation of ground, consolidating, rough ramming of soil to prepare the area of 120 SQM surrounding for sub floor concrete by using semi-skilled labours including all kind of cutting tools, cleaning materials and safety equipments complete. Note: PCC shall be measured and paid separately under relevant item
M&L cement concrete in sub-base, sub-floors and pavings of 100mm thickness by using cement concrete type 1:3:6 type C2 (40mm graded aggregate) all as specified and as directed by Engineer-in-Charge
Tropical Refrigeration (BID ID -3298537)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .