| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | ₹1.2 Cr | 1 | Accepted-AOC ACCEPTED BEING THE LOWEST TENDERER |
| 2 | 2₹1.3 Cr+₹5.1 L (4.10%)Rejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹1.3 Cr+₹5.1 L (4.10%) | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 3 | 3₹1.5 Cr+₹22.5 L (18.2%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | ₹1.5 Cr+₹22.5 L (18.2%) | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 4 | Rejected-Technical GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | - | - | Rejected-Technical Not submitted MoU. |
| 5 | Rejected-Technical COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | - | - | Rejected-Technical Not submitted MoU. |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
21 Aug 2023, 6:00 pmClosed
CWE (AF) Jorhat
HQ CWE (AF) Jorhat, Rowriah, Assam - 785005
84002/E8 REMOVAL AND REINSTALLATION OF APPROACH LIGHTS AT AF STN JORHAT UNDER GE (AF) JORHAT
2023_MES_593683_2
84002/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AF STN JORHAT UNDER GE (AF) JORHAT
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE (AF) Jorhat
₹2.2 L
Yes
15 Nov 2023
15 Jul 2023
23 Aug 2023
16 Jul 2023
21 Aug 2023
31 Jul 2023
Amount
Execution of complete Total Station survey of the runway and marking of inset light points to be installed on runway complete all as specified and as directed. Note :- After completion of the survey the complete report along with drawing shall be submitted by the contractor to GE and confirmation of quantity of item which is required to complete the work shall be submitted by the contractor to GE.
Supply and installation of elevated Halogen type unidirectional high intensity approach light fitting suitable for use with 200W, 6.6 halogen lamp complete with all accessories, complete clear lens, lens holder, lens clamping mechanism, Prefocus lamp holder, central column assembly, breakable coupling, spring and plain washer rubber gasket,and other accessories and lamp and omni directional lens but without base plate complete conformimg to specified particular specificationsas per ICAO. all as specified and directed by Engineer -in charge. Make : Vardhaman, Model No. VAS-APL-1 or equivalent model in AMA/ATG/ADB Safe Gate/Honeywell
Supply and fixing of high Intensity Unidirectional Inset approach light fitting complete with Halogen Lamp for use in 6.6 A airfield lighting series circuit. Halogen inset lights fitting complete with all accessories including cable lead side entry, one L-823 two pole socket, shallow base, cable lead, reflector and complete in all respect as required and coforming to latest ICAO specifications and particulars specifications al as per directed by Engineer-in-Charge. Make :ATG Model No. ZA480 or equivalent model in AMA/ Vardhaman/ ADB Safe Gate/ Honeywell
Supply and installation of 12" Dia High-intensity Inset Runway edge light clear/Yellow 2X105 watt halogen lamp including for aviation visual aid conforming to FAA/ICAO specification, accessories including shallow base & matching body, lens, filter, secondry lead, single plug, complete etc all as specified, ready for site installation suitable for 6.6 A etc. as required and as directed by Engineer-in-Charge Make : ATG Model No. ZA483 or equivalent model in AMA/ Vardhaman/ ADB Safe Gate/ Honeywell
Supply and Installation of C.I isolating transformer housing box, water tight round type, metal container of outside dia 330 mm, and maximum height 450 mm made of 10 mm thick cast iron moulding all round, except the top surface, which is 15 mm thick, cast iron moulding suitable to receive a light fitting base plate on the top and underground housing associated with transformer power cable and having a clear hole at two side surface centre 75 mm above bottom surface suitable to receive of 50 mm outer dia.HDPE/G.I. pipe and check nut as required. The box should have two SS earth bolts of M10 x 30 mm tapped inside near the hole away from the hole centre and having a drain hole at the bottom suitably tapped to receive 15 mm dia, "B" class GI pipe and having clear opening of 220 mm at the top surface and 6 nos. M10 tapped hole at the hole centre 260 mm to receive fitting base plate and bolts and confirming etc. complete as required. Make : Vardhaman Model No. VAS-C1 or equivalent model in Deepak Metal Works/Kanishak Trading Company/ Hare Krishna Industries
Supply and laying of 1Core x6 sq. mm size 5 KV grade copper conductor XLPE insulated,PVC insulated & PVC sheathed, single core, copper braided AFL cable laid in trenches/ inside conduit (GI/PVC) using wire pulling rod or by other means, complete,all as specified and directed by Engineer-in-Charge. Make : Ankur/Rallison/Unika/Eupen
Supply only of 1 Core X 4 Sq.mm. 600 V GRADE AGL SECONDARY CABLE With Multistranded Annealed Tinned Copper Conductor, EPR Insulated, Color Coded (Red & Black), Laid up & PCP/TPE Sheathed. all as specified and directed by Engineer-in-Charge. Make : Ankur/Rallison/Unika/Eupen
Supply and Fixing of 5 KV 50 Hz, PCP encapsulated isolating Transformer Confirming to ICAO, suitable for individual series lamps airport lighting circuits. The transformers shall be designed to be waterproof and suitable for direct burial in the earth or installation in a base complete as per specifications of capacity 200 Watt complete all as per specified and directed by Engineer-in-Charge. Make : ATG Model No. L-831 or equivalent model in ADB Safe Gate/ Bildal Electrical Private Limited/Vardhaman
Supply and making connection of 5 KV grade ESNA connector and suitable for field attachment with 5kV grade PVC insulated, PVC sheathed single core- 6 sqmm copper conductor conforming to technical specifications etc. complete as required and specified directed by Engineer-in-Charge Make : Vardhaman Model No. CAS-PC or equivalent model in EFLA/ATG/ADB Safe Gate
Supply and making connection of Plug and receptacles suitable for secondry lead of 2X4 Sqmm EPR insulated PCP sheathed copper conductor of secondary airfield lighting cable etc. complete as required and specified. Make : EFLA Model No.KD501.1 or equivalent model in ATG/ADB Safe Gate/Honeywell
M&L for Cutting of Bituminous surface/PCC surface with Kerf cutting machine of suitable size and depth for laying of secondary cable and fixing for inset light in bituminous/ PCC area of runway/taxiway/i/c kerfing, chiselling, cleaning and refilling the groove with suitable sealant material as required and making good as per specified directed by Engineer-in-Charge
(a) For secondary cable (up to 10mm width and 30 mm depth)
(b) For secondary cable (up to 10mm width and 50 mm depth)
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper wire of size 5mm dia as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 32 mm dia GI pipe "medium grade" for protection of earth lead and connected to test point or as directed including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and RCC Cover of size 450X450X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Soil upto a distance of 50.00 mtr and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion , including taking down unserviceable earthing complete all as specified and as directed Engr-in-charge. Note:-After installation of earthing testing to be done in front of Engr-in-charge and record of the same shall be presented with the bill .
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. Note:- For item No. 5, 19 & 21
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. Note:- For item No. 5, 19 & 21
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M&L Sand Cushioning (dry) in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).
S&F Sub-Class B brick, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
Supply and laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of 50mm dia complete all as specified and directed.
Supply and Fixing of 20mm to 40 mm flexible conduit for secondary cable as directed and specified
Supply and laying for 5.00 mm dia Copper wire earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and as directed.
Supply laying & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables heavy duty 11000 Volts grade, HT of size single core 95 Sqmm 3 core with aluminium conductor (earthed) cable.( From Runway end 04 to PS-II)
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
Horizontal boring under road, pavement, hard standing by trenches less technology using ultra sound technique and necessary machine including HDPE pipe upto 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Supply, fixing, grouting and painting cable route indicator made up of Factory made Precast RCC slab of size 100 cm x 40 cm x 80 mm thick duly embossed with "MES HT Cable" ",Size of Cable and grouting on the route of HT cable complete. Note :- (i) Unit rate of item includes excavation, PCC foundation for erection of route indicator. (ii) Slab of route indicate to be provided with min 4 Nos x 8 mm diameters TMT bars along length of slab with 7 Nos cross bar 6 mm dia in reinforcement with shuttering. (iii) Route indicator RCC slab to painting with two coat of red colour synthetic enamel paint over on one coat of white primer base all as specified and directed by Engr - in - Charge.
Supply, install, testing & commissioning of HT feeder pillar box suitable for 11000V, 3 phase, 50Hz 630Amps, AC system as per CPRI standards and IE rules, bus bar insulator CPRI approved factory made, totally enclosed, self supporting button structure/ cubicle, weather & vermin proff, protection IP-66, suitable for outdoor use, with cable entry, structure made out of 3.15mm thick CRCA steel sheets with angle irin frame work and legs 60 cm above normal ground level, made of ISA -75x75x6mm with four legs frouted to PCC(1:2:4) type B-1 foundation block of adequate size with suitable mounting arrangement for alluminium bus bar, three phase supported with suitable size hight strength SMC/DMC material insulator and suitable size brass nuts, bolts and washers with heat shrinkable PVC sleeving, with sloping cannopy at top, double hingde doors at front and rear with neoprene rubbergasket, suitable locking arrangement and bolted shutters, provision of louvers at sides, danger plates, erthing strip point and bottom detachable gland plate complete with zinc/chromium plated nuts, bolts and washers etc, structure treated under 7 Tank metel treatment process and duly powder coted incl all earthwoked complete all as specified and directed.
M&L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode , buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earting test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) for protection of earth lead conductor and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Bi-Directional Inset Runway Centreline fitting - clear/clear lenses, 8" diameter, clear anodised finished body, 2 x 48W 6.6A reflector lamps and 1 x 300mm `B' type plug lead complete all as specified and directed. Make : ATG Model No. ZA181 or equivalent model in ADB Safe Gate/ AMA/Vardhaman/Honeywell
Supply and fix 8 inches shallow base for Inset type Runway Centreline Light complete all as specified and directed. Make : ATG Model No. ZM203 or equivalent model in ADB Safe Gate/ Honeywell
Supply and fix 100 W, 20/6.6 Amps, 5 KV grade, 50 Hz, series Isolating Transformer encapsulated in polyester resin, finally moulded in neoprene type rubber with primary and secondary connectors etc and all other standard accessories required as per ICAO and conforming to technical specifications.
M & L for taking out dummy joints and cleaning the joints properly upto a depth of dummy joints and applying closed cell, medium density, cross linked polyethelene foam back up rod of 25 mm dia , priming top 12 mm with approved primer and filling with polyurethane bnased sealant, applying masking tape on edges of joint to prevent accidental spillage of sealant and emoving the maslking tape after filling of sealant all as per the directions of the manucfactuirer, complete all as specified and as ditected. Note :- i) Repair will be carried out through an authorized appilcator. ii) X seal traffic loop ( flexible polyester loop and lighting sealant) fron X-Caliber/Shaliseal company. iii) Cables are lying in the joints.If cables damaged during execution, it will be repalced on own cost basis.
NSC Projects Pvt. Ltd.
HEMONTA DAS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .