Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 Acepted | |
| 2 | L2₹29.3 L+₹5.9 L (25.3%)Rejected-Finance 25 SHIV SAROVER COLONY GARH ROAD MEERUT 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Reject due to not being L1 | |
| 3 | L3₹29.7 L+₹6.3 L (27.1%)Rejected-Finance H NO 28 FIRST FLOOR E BLOCK KARMPURA WEST DELHI 110015 | WEST DELHI | DELHI | 110015 | L3 | Rejected-Finance Reject due to not being L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Meerut Cantt
Garrison Engineer (South) Meerut Cantt The Mall Road Meerut Cantt Distt Meerut-250001(UP)
MAINTENANCE / REPAIR OF COOLING APPLIANCES AND FANS INCLUDING CONNECTED WORKS UNDER AGE E/M-II OF GE (SOUTH) MEERUT CANTT
2025_MES_694510_1
GE/MRT/S/8198/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (South) Meerut
₹90,000
1 Apr 2025
23 Jan 2025
8 Mar 2025
23 Jan 2025
28 Feb 2025
14 Feb 2025
Amount
Taking down old unserviceable/ non-functional ceiling fan from site and M&L for servicing of ceiling fans including rewinding of burnt coils of ceiling fans with super enamalled copper winding wire of existing size for 1200 mm sweep, AC 230 volts including greasing, oiling, fitting/reassembling of fan including repair / replacement of minor accessories like split pin, MS check nut and condensor holder, rubber reel of suitable size, MS nut bolt 50mm long 8mm dia and making fan serviceable & in running condition including PVC flexible copper twin core 23/0.0076 size also refix the same complete all as specified and directed. Note:- For item No 1&2 - (i) Re-winding & repair work will be carried out in AGE E/M-II (S) store yard (ii) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
All as per item No 1.00 here-in-before but fans1400 mm sweep complete all as specified and directed.
Supply and fixing in repair ball bearing of Size 6201. Complete set all as specified an directed.
Supply and fixing in repair Ball bearing of Size 6202. Complete set all as specified an directed.
Supply and fixing in repair capacitor oiled filled 2.5 MFD 230 Volts. Complete set all as specified an directed.
Supply and fixing in repair capacitor oiled filled 3.15 MFD 230 Volts. Complete set all as specified an directed.
Supply and fixing in repair PVC canopies for ceiling fans upper / bottom Complete set all as specified an directed.
Supply and fixing in repair blade for ceiling fan made out of alluminium heavy duty as per sample suitable for 1200 mm sweep ceiling fans. Complete set all as specified an directed.
Supply and fixing in repair blade for ceiling fan made out of alluminium heavy duty as per sample suitable for 1400 mm sweep ceiling fans. Complete set all as specified an directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old unserviceable complete all as specified and directed. Note: Old unserviceable ceiling fan will be deposit to AGE E/M-II yard.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1400mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including taking down old unserviceable complete all as specified and directed. Note: Old unserviceable ceiling fan will be deposit to AGE E/M-II yard.
Supply and fixing in repair down rod (connect from roof /truss to ceiling fan clamp) made out of MS pipe medium grade of lengh as per site requirement of 15mm dia threaded/suitable Nos of drilled hole and length as per sample suitable for hanging the ceiling fans and including two coats of synthetic enamelled paint complete all as specified and directed.
Supply and fixing in repair down rod made out of MS pipe medium grade lengh not less than 300 mm of 15mm dia threaded/suitable Nos of drilled hole suitable for hanging the ceiling fans and including two coats of synthetic enamelled paint complete all as specified and directed.
Supply and fixing in repair hanging clamp with rubber reel, nut bolts and split pin complete all as specified and directed.
Material and labour for preparaton of old steel surfaces painting of ceiling fan including blades of any description by appyling one coat of synthetic enamel paint complete including writing MES Nos complete all as specified and directed.
EXHAUST FANS :- Taking down old unserviceable exhuast fan from site as directed and M&L for servicing including rewinding of Exhaust fans burnt coils with enamalled copper winding wire for exhaust fans 230 Volts 400/450 mm sweep, including minor accessories like MS screw of suitable size, MS nut bolt, PVC flexible copper wire etc required for making serviceable in running condition and refix with a gurantee for one year complete all as specified an directed. Note:- Re-winding & repair work will be carried out in AGE E/M-II (S) store yard. (ii) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
All as per item No 16.00 here-in-before but 300 mm sweep. Complete set all as specified an directed.
All as per item No16.00 here-in-before but 230/250 mm sweep. Complete set all as specified an directed.
Supply and fixing in repair blade heavy duty (set of four blades) made of metal suitable for Exhaust fans size 450/400 mm sweep with screw. Complete set all as specified an directed.
Supply and fixing in repair blade made of metal (set of three blades) suitable for Exhaust fans 300 mm sweep with screw. Complete set all as specified an directed.
Supply and fixing in repair blade made of metal suitable for Exhaust fans 230/250 mm sweep with screw etc of any make as directed by Engr-in-Charge.
Supply and fixing exhaust fans motor copper wounded for 230/250mm sweep, 230 volts ,single phase 50 Hz, RPM not less than 1300 suitable for following sizes of metallic body exhaust fan including legs, nut and bolts of suitable size to fix the motor with frame including taking down old unserviceable fan motor complete all as specified and directed.
All as per item No 22.00 here-in-before but 300 mm sweep. Complete set all as specified an directed.
All as per item No 22.00 here-in-before but 450/400 mm sweep. Complete set all as specified an directed.
Supply and fixing in repair exhaust fan frame/body of metal sultable for 230/250mm sweep of metal body exhuat fan including all accessories to fix the motor with frame complete all as specified and directed.
All as per item No 25.00 here-in-before but300 mm sweep. Complete set all as specified an directed.
All as per item No 25.00 here-in-before 450/400 mm sweep. Complete set all as specified an directed.
Supply and fixing Exhaust fan 300 mm sweep , single phase 50 HZ , speed 1400 RPM , air delivery 1300 Cum not more than 80 watt including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring including taking down old unserviceable exhaust fan. Complete set all as specified an directed. Note: Old unserviceable exhaust fan will be deposit to AGE E/M-II yard.
Supply and fixing Exhaust fan 450 mm sweep , single phase 50 HZ , speed 1400 RPM , air delivery 1900 Cumm not more than 100 watt including taking down and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring including taking down old unserviceable exhaust fan complete all as specified and directed. Note: Old unserviceable exhaust fan will be deposit to AGE E/M-II yard.
Material and labour for painting of Exhaust fan including blades of any description by appyling one coat of synthetic enamel paint complete including writing MES Nos and preparation of surfaces. Complete set all as specified an directed.
Supply and fixing in repair exhaust fan frame complete sultable for site requirement180/200/ 230 /250/300 mm sweep fresh air fan made of PVC complete all as specified and directed.
Supply and fixing in repair motors 180/200/ 230 /250/300 mm sweep suitable for site requirement for PVC fresh air fan 230 volts single phase 50 Hz, marked complete all as specified and directed.
Material and labour servicing including rewinding of wall mounting / cabin fans burnt coils with super enamalled copper winding wire for wall mounting / cabin fans AC 230 Volts of any size / sweep, complete including greasing, oiling and minor accessories and making serviceable in running condition with a gurantee for one year complete all as specified an directed.
Supply and fixing wall fan 400 mm sweep copper wounded with pull cord to control speed and oscillation,three blades,230 volts,50 Hz ,speed not less than 2000 RPM, air delivery not less than 90 CUM not more than 110 watt including all accesories for fixing it on wall including taking down old unserviceable wall fan complete all as specified and directed. Note: Old unserviceable wall fan will be deposit to AGE E/M-II yard.
WINDOW TYPE AC/SPLIT TYPE AC :- Servicing of window / split type AC of any capacity and make including cleaning condensor, cooling unit, cleaning of air filter and refixing the same after repair including testing and commmissioning complete all as specified and directed. Note :- (i) Service will be done at the site will consider only one time if machine will become unserviceable after service but spare parts will be cosidered. (ii) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (iii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
Supply and fixing in repair starting capacitor 100/120 MFD complete all as specified & directed.
Supply and fixing in repair starting capacitor 120/150 MFD complete all as specified & directed.
Supply and fixing in repair running capacitor 36 MFD for window/Split type AC complete all as specified & directed.
Supply and fixing in repair running capacitor 50-60 MFD for window type AC/split type AC complete all as specified & directed.
Supply and fixing in repair starting relay suitable for window/split type AC for any Capacity complete all as specified & directed.
Supply and fixing in repair fan blade of compressor cooling fan of window/split type AC indoor unit for any type complete all as specified & directed.
Supply and fixing in repair fan blade of blower fan of split type/window AC for any capacity complete all as specified & directed.
Supply and fixing in repair condensor coil for 1.5 ton/ 2 Ton window type AC/ Split Type AC complete all as specified & directed.
Supply and fixing in repair remote control unit of suitable capacity of split type AC/ Window Type AC complete all as specified & directed.
Supply and fixing in repair Air filter made of PVC/Nylon fiber suitable for 1.5 / 2 Ton window/split type AC complete all as specified & directed.
Supply anf fixing in repair blower motor copper wounded suitable size for air conditionsers 1.5 / 2 Ton capacity as per site requirement. Complete set all as specified an directed.
M&L for replacement in repair of complete wiring kit of window type AC/Split Type AC 1.5 Ton capacity complete all as specified & directed.
Supply and fixing indoor unit suitable for split type air conditioner of capacity 1.5 Ton suitable for any existing make either for invertor type/ non inverter type complete all as per site requirement including all fixing accessories including taking down old unserviceable complete all asspecified and directed.
Taking down carefuly the hermetically sealed /Rotary compressor unit from window type/Split type Air conditioner 1.5 ton and replacing it with new receprocating /rotary/Scroll type as per site requirement and gas charging complete in all respect and testing at required pressure after re-installing at site including replacement of mounting rubber bushes, nut bolts etc and testing after installation of following capacities of compressors. Note:- (i) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (ii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
All as per item No 49.00 here-in-before but 2 Ton complete all as specified and directed.
Supply and fixing outdoor unit with copper condenser,rotary compressor 230 volt , 50HZ suitable for split type air conditioner of capacity 1.5 Ton suitable for any existing make either for invertor type/ non inverter type complete all as per site requirement including all fixing accessories including taking down old unserviceable complete all as specified and directed.
Supply and fixing bracket of iron size of angle section 50x50x60mm suitable for fixing window type AC/ Split type AC (for Out door Unit) including nut and bolts required as per site complete all as specified and directed.
Supply & fix in replacement metal plug top 20 Amps for AC complete all as specified and directed.
Supply & fix in replacement of metal plug Socket 20 Amps for AC complete all as specified and directed.
Material and labour for Charging of HFC refrigent or any other latest refrigerant as per site requirement in AC with required quantity, testing flushing complete system against leakage etc complete all as specified & directed.
Supply and fixing in repair PCB for Indoor UNIT of air conditioner suitable for 1.5/2 TON AC as per site requirement complete all as specified and directed.
Supply and fixing in repair AC remote as per site requirement complete all as specified and directed.
Supply and fixing in repair PCB for window type air conditioner of suitable for 1.5/2 TON AC as per site requirement complete all as specified and directed.
WATER COOLERS : - M&L for Repair/servicing of water cooler including cleaning of water tank with suitable chemicals and fresh water for upto and including 150/180 Ltr capacity complete all as specified and directed. Note:- (i) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (ii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
Supply and fixing in repair starting relay suitable for water coolers of any capacity upto and including 150/180 Ltr as per site requirement complete all as specified and directed.
Supply and fixing in repair starting capacitor 40-60 MFD suitable for water cooler complete all as specified and directed.
Supply and fixing in repair starting capacitor 100-120 MFD suitable for water cooler complete all as specified and directed.
Supply and fixing in repair drain pipe of water coolers of size not less than 25 mm in dia, superior quality complete all as specified and directed.
Supply and fixing in repair overload relay of water cooler of any capacity 40/80 ltrs and 150/180 ltrs complete all as specified and directed.
Supply and fixing in repair running capacitor 10 MFD for water cooler complete all as specified and directed.
Supply and fixingin repair running capacitor 25 MFD for water cooler complete all as specified and directed.
Supply and fixing in repair running capacitor 36 MFD for water cooler complete all as specified and directed.
Supply and fixing in repair condenser fan motor single phase complete all as specified and directed.
Supply and fixing in repair thermostat suitable for upto and including 150/180 Ltr water cooler any type complete all as specified and directed.
Supply and fixing in repair copper condensor coil suitable for water cooler of capacity 40/80 ltrs complete all as specified and directed.
Supply and fixingin repair copper condensor coil suitable for water cooler of capacity 150/180 ltrs complete all as specified and directed.
Supply and fixing in repair PVC float valve 15 mm bore with PVC heavy duty ball and rod complete all as specified and directed.
Supply and fixing in repair brass chromium plated push cock of 15 mm bore complete all as specified and directed.
Supply and fixing in repair wiring kit for water coolers of any capacity and make complete all as specified and directed.
M&L for reparing of leakage of water cooler storage tanks by soldering/brazing work complete all as specified and directed.
M&L for taking out carefuly the hermetically sealed defective compressor from water cooler 40/80 ltrs and refixing it after repair with factory repaired from the authorised dealer and gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation. Complete set all as specified an directed.
All as per item No 76.00 here-in-before but water cooler of capacity of 150 to 180 Ltrs complete all as specified and directed.
Material and labour for Charging of HFC refrigerent gas in water cooler with required quantity after flushing out and testing the system against leakage and repair of connected works including replacement of copper capillary tube of any capacities and testing the same after re-installation complete all as specified and directed.
Material and labour for re-winding of fan motor of water coolers of any capacity with supper enameled copper wire complete all as specified and directed.
M&L for preparation of surface of water cooler by rubbing with emery paper then painted with help of spray with one coat of synthetic enamel paint of approved make without damaging other parts / wiring of the machine and including writing of serial No / MES No and SM No on the machine complete all as specified and directed.
S&F in repair float valve of size 15mm suitable for water cooler as per site requirement and as speicified and directed by Engr-in-charge.
S&F in repair for stop cock of size 15mm suitable for water cooler as per site requirement and as speicified and directed by Engr-in-charge.
REFRIGERATORS :- Repair / servicing of refrigerators of any capacity including writing of serial No / MES No and SM No on the machine complete all as specified and directed.
Supply and fixing copper capillary tube of any capacities and putting the refrigerators in perfect working condition and testing the same after re-installation complete all as specified and directed.
Supply and fixing in repair starting relay suitable for upto 310 Ltr capacity any type and capacity of refreigerators complete all as specified and directed.
Supply and fixing in repair thermostat switch with knob suitable for any type upto 310 Ltr capacity of refreigerators complete all as specified and directed.
Supply and fixing in repair refrigerators tray/grill set as per sample suitable for (videcon/kelvinator/LG/Whirlpool) complete all as specified and directed.
Supply and fixing in repair overload relay upto 310 Ltr capacity of refrigerators of any make and capacity complete all as specified and directed.
Supply and fixing in repair freezer assembly suitable for any capacity and make of refrigerators complete all as specified and directed.
Supply and fixing in repair condenser coil suitable for upto 310 Ltr capacity refrigerators of any capacity complete all as specified and directed.
Taking out carefuly the hermetically sealed defective compressor for capacity 165 Ltrs to 250 Ltrs from refrigerators and refixing it after repair with factory repaired from the authorised dealer and gas charging complete in all respect and testing at required pressure incl replacement of mounting rubber, bushes nut bolts etc and testing after installation complete all as specified and directed.
All as per item No 91.00 here-in-before but of capacity 250 ltrs to 310 ltrs complete all as specified and directed.
Material and labour for charging of refrigerent gas with R-134 ,required quantity after flushing out and testing the system against leakage and repair of connected works including replacement of copper capillary tube of any capacities and putting the refrigerators in perfect working condition and testing the same after re-installation complete all as specified and directed.
Supply and fixing PCB for refrigerator of any capacity from 250 to 310 Ltr suitable for all as per site requirement complet all as specified and directed.
DESERT COOLER : - Taking down and Repair and servicing of desert cooler body of any size including spray painting externally after scrapping out the existing paint with one coat of synthetic enamel paint on outer surfaces and one coat of anticorrosive paint on inner surfaces and refixing in the same position complete all as specified and directed. Note:- (i) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (ii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
Fixing of desert cooler including connetion of water pipe and all required accessories to fix desert cooler with its own arrangement irrespective of height/ floor after collecting desert coller from E/M yard complete all as specified and directed.
Supply and fixing in repair desert cooler kit (kit comprises desert cooler motor , pump, metal exhaust blades). Desert cooler motor 500 mm sweep , copper wounded , speed not less than 1350 RPM, 3 speed motor AC, 230 volts single phase complete including clamping fixing materials of nuts bolts and washers etc complete all as specified and directed.
Supply and fixing in repair submersible mini pump AC 230 volts 50 cycle power consumption Not more than 18 watt complete all as specified and directed complete all as specified and directed.
Supply anf fix complete body of desert cooler made of GI Sheet powder coated with elegant finish ,sump capacity should not less than 75 lit, , thickness of sheet- of sump tank not less than-1.0mm, thickness of top of the body not less than -0.80mm complete all as specified and directed.
Supply and fixing in repair wood wool pads for any type of desert coolers complete all as specified and directed.
Supply and fixing in repair pipe 15mm dia PVC medium quality complete all as specified and directed.
Supply and fixing in repair metal front grill of Desert cooler of suitable size and gauge as per site requirement complete all as specified and directed.
Supply and fixing in repair metal panel suitable for single phase Desert cooler (set of three) as per sample complete all as specified and directed.
Supply and fixing in repair condenser 4MFD suitable for desert cooler complete all as specified and directed.
Supply and fixing in repair PVC water distributor 3 way 15 mm dia for Desert cooler complete all as specified and directed.
Supply and fixing in repair PVC elbow 15 mm size suitable for Desert cooler complete all as specified and directed.
Material and labour for rewinding of fan motor of desert cooler complete with specific gauge of supper enamel copper winding wire varnishing and making connection to the desert cooler complete all as specified and directed.
Supply and fix in repair desert cooler blade of metal of size upto 450mm suitable for existing cooler Motor complete all as specified and directed.
DEEP FREEZER :- Servicing of deep freezer of including and upto 320 Ltr complete all as specified and directed. Note:- (i) The replacement of defective / non-functional parts shall be measured & paid for separately under appropriate item of Sch 'A'. (ii) The rates for above items are deemed to include for transportation to & fro of fans to workshop if required and approved by the Engr-in-charge for necessary repairs.
M&L for taking out carefuly the hermetically sealed defective compressor of capacity 300 to 320 Ltrs from Deep -Freezer and providing refixing it after repair with factory repaired from the authorised dealer and gas charging complete in all respect and testing at required pressure and re-installing at site incl replacement of mounting rubber, bushes nut bolts etc and testing after installation. Complete set all as specified an directed.
M&L for taking out carefuly the hermetically sealed defective compressor for capacity 250 to 275Ltrs from Deep -Freezer and providing refixing it after repair with factory repaired from the authorised dealer and gas charging complete in all respect and testing at required pressure and re-installing at site incl replacement of mounting rubber, bushes nut bolts etc and testing after installation. Complete set all as specified an directed.
Charging of refrigerent gas for Deep Freezer with R-134 A, required quantity after flushing out and testing the system against leakage and repair of connected works including replacement of copper capillary tube of any capacities including refixing, testing, commissioning the same complete set all as specified an directed.
Supply and fixing in repair main control board/ panel to control temperature including thermostate of deep freeezer as requirement of site complete all as specified and directed.
Supply and fixing in repair copper condeser coil of deep freezer as per site requirement complete all as specified and directed.
Supply and fixing in repair motor with blade to cool condenser coil as per motor suitable upto 320 Ltr Capacity site requirement complete all as specified and directed.
Supply and fixing in repair starting relay of motor suitable upto 320 Ltr Capacity any capacity complete all as specified and directed.
Supply and fixing in repair overloadof of motor suitable upto 320 Ltr Capacity any capacity complete all as specified and directed.
Supply and fixing in repair starting / running capacitorof of motor suitable upto 320 Ltr Capacity any capacity complete all as specified and directed.
VOLTAGE STABILIZER :- Material and labour for rewinding of burnt transformer using super enamel copper wire of existing size as directed by EIC for the of capacity 5 KVA of any make of voltage stablizers.
All as per item No. 120.00 here-in-before but 4 KVA cap of any make.
All as per item No. 120.00 here-in-before but 3 KVA cap of any make.
All as per item No. 120.00 here-in-before but 2 KVA cap of any make.
All as per item No. 120.00 here-in-before but 1 KVA cap of any make.
Supply and fixing tranformer copper wounded suitable for voltage stabilizer of capacity 5 KVA with fixing accessories complete all as specified and directed.
All as per item No. 125.00 here-in-before but 4 KVA capacity.
All as per item No. 125.00 here-in-before but 3 KVA capacity.
All as per item No. 125.00 here-in-before but 2 KVA capacity.
All as per item No. 125.00 here-in-before but 1 KVA capacity.
Supply and fixing automatic voltage stabilizer capacity 2KVA work efficiently for input voltage variation between 150 to 270 volts, digital display complete all as specified and directed.
Supply and fixing automatic voltage stabilizer capacity 4KVA work efficiently for input voltage variation between 130 to 300 volts, digital display complete all as specified and directed.
Supply and fixing automatic voltage stabilizer capacity 1 KVA work efficiently for input voltage variation betwwen 150 to 270 volts, digital display complete all as specified and directed.
Supply and fixing of replacement of high/low cut off with time delay circuit of the following capacity of the voltage stabilizer of capacity 5 KVA cap of voltage stablizer. Complete set all as specified an directed.
All as per item No.133.00 here-in-before but.4 KVA capacity.
All as per item No.133.00 here-in-before but 3 KVA capacity.
All as per item No.133.00 here-in-before but 2 KVA capacity.
All as per item No.133.00 here-in-before but1 KVA capacity.
Supply and fixing in repair volt meter AC, 230 volt suitable for 5kv voltage stabilizer complete all as specified and directed.
Supply and fixing in repair indicator bulb suitable for voltage stabilizers complete all as specified and directed.
Supply and fixing in repair copper wire three core 1.5 sqmm complete all as specified and directed.
Supply and fixing in repair copper wire three core 2.5 sqmm complete all as specified and directed.
Supply and fixing in repair plug 3 pin 5/6 Amp suitable at site complete all as specified and directed.
Supply and fixing in repair plug 3 pin 15/16 Amp suitable at site complete all as specified and directed.
Supply and fix Exhaust fan 250/230 mm sweep , single phase 50 HZ , speed 1200 RPM , air delivery 1100 Cumm not more than 80 watt all including making hole if required including taking down old unserviceable Complete set all as specified an directed. Note: Old unserviceable exhaust fan will be deposit to AGE E/M-II yard.
Supply and fix light duty Exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, not less than Rpm 2000, copper winding and fixing accessories 230 Volt and 400mm sweep with and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring including taking down old unserviceable exhaust fan complete all as specified and directed. Note: Old unserviceable exhaust fan will be deposit to AGE E/M-II yard.
Supply, install, testing and commissioning single phase two wire, single source direct connected pre paid key pad based BIS marked IS 15884 digital energy meter, 240 volts, 10 to 60 Amps, accuracy class I, including parallel Customer Interface Unit (CIU) fixed on suitable size PVC/wooden board, soft token transfer device (STTD) & fixed on suitable size PVC board at consumer house with facility of meter to generate ABC (Authenticated builling code) for monthly energy usage bill generation, having LCD type display, calibration LED numeric key pad for token entry with RS 232 communication port, credit status indication, push button for scroll & having features for load disconnection in case the credit limit becomes zero or increase of load more than permissible limit, reconnection & disconnection of load, buzzer at CIU to give alarm for of low credit and overloading. Data download port for last 25 tamper events and load survey with all standard anti tamper features including sealing facility complete with and including polycarbonate transperent box of suitable size for housing the meter complete all as specified and directed. Note- Unserviceable meter will be deposited ay E/M yard.
Supply, install, testing and commissioning three phase four wire, single source direct connected pre paid key pad based BIS marked IS 15884 digital energy meter, 3x240 volts, 10 to 60 Amps, accuracy class I, including parallel Customer Interface Unit (CIU), fixed on suitable size PVC/wooden board, soft token transfer device (STTD) & fixed on suitable size PVC board at consumer house with facility of meter to generate ABC (Authenticated builling code) for monthly energy usage bill generation, having LCD type display, calibration LED numeric key pad for token entry with RS 232 communication port, credit status indication, push button for scroll & having features for load disconnection for the credit limit becomes zero or increase of load more than permissible limit, reconnection & disconnection of load, buzzer at CIU to give alarm of low credit and overloading. Data download port for last 25 tamper events and load survey with all standard anti tamper features including sealing facility complete with and including polycarbonate transperent box of suitable size for housing the meter complete all as specified and directed. Note- Unserviceable meter will be deposited ay E/M yard.
Supply and fix CIU(Customer Interface Unit) suitable for single Phase/ three Phase prepaid Meter including taking down old unserviceable. Complete set all as specified an directed. Note: Unserviceable CIU will be deposited AGE E/M-II Yard.
Supply only soft token transfer Device (STTD ). Complete set all as specified an directed. Note- Unserviceable meter will be deposited ay E/M yard.
Material and labour for sub main wiring with two pair (four core) insulated transparent 0.5Sqmm wire 1.1 KV telephone wire in and including PVC medium grade conduit 15mm dia fixed on wall /roof /floor medium grade with suitable clamps & fixing screws from meter to CIU unit. Complete set all as specified an directed.
A.V. ASSOCIATES (BID ID -3252011)
GE WORLD (BID ID -3251856)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .