Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹15.7 L+₹2.1 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
23 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2020_MES_357658_2
GE (AF) NAL/T-08/2020-21
Open Tender
Street Lighting
Item Rate
270 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹44,000
Yes
GE (AF) NAL
1 Oct 2020
14 Aug 2020
25 Sept 2020
14 Aug 2020
23 Sept 2020
4 Sept 2020
18 Aug 2020 - 20 Aug 2020
22 Aug 2020
60 days
Amount
M&L checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide, T-5, LED Lights, Post top, Trafic light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) other than those mentioned in item No 2 to 11 below either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
Note for item No. 1.00 :- (i) New parts shall be measured and paid for separately under relevant item of this schedule as 'Supply only'. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, wire for internal wiring,gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost there of is deemed to be included in the rates quoted by the contractor in above item including rectification of cable fault & over head fault by fault finding/identification. (iv) Contractor shall be paid only one time labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor shall attend the said job as and when ordered by Engineer-in-Charge and replace the spare parts / fittings immediately without losing the time. (vi) Immediately, on acceptance of contract, material shall be brought by the contractor on priority basis after getting approved and shall attend the complaint on priority basis. (vii) Site of work is scattered in Domestic and Technical area and the contractor shall consider this aspect while quoting the rates. (viii) Contractor's supervisor shall attend the office of AGE E/M at 0900 hrs every day (except holiday) to get the task / location / nature of compaint and in the evening, shall give feed back of compaint.
Supply only PVC insulated and sheathed copper conductor 1.5 sqmm two single core multistrand cable for electric connection from overhead line / junction box to street light complete all as specified and directed.
Supply only HPSV lamp 250 watt elliptical / tubular E-40, complete all as specified and directed. Make:-Crompton or equivalent of Havells/Philips.
Supply only HPSV lamp 400 watt elliptical / tubular E-40, complete all as specified and directed. Make:- Crompton or equivalent of Havells/Philips.
Supply only HPSV lamp 70 watt elliptical / tubular E-27, complete all as specified and directed. Make:- Crompton or equivalent of Havells/Philips.
Supply only HPSV lamp 150 watt elliptical / tubular E-40, complete all as specified and directed. Make:-Crompton or equivalent of Havells/Philips.
Supply only electronic igniter for integral luminaries suitable for 70W / 150W / 250W / 400W HPSV/MH fitting, complete all as specified and directed. Make:- Crompton Cat Part IGN112S/MH or equivalent of Bajaj/Havells.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 400 Watt suitable for HPSV/HPMV/metal halide 400W lamp complete all as specified and directed. Make:- Crompton Cat Part HDBL 40S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 250 Watt suitable for HPSV/HPMV/metal halide 250W lamp,all as specified and directed. Make:-Crompton Greaves Cat Part HDBL 25S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 70 Watt suitable for HPSV/HPMV/metal halide 70W lamp, complete all as specified and directed. Make:- Crompton Greaves Cat Part HDBL 07S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 150 Watt suitable for HPSV/HPMV/metal halide 150W lamp, complete all as specified and directed. Make:- Crompton Greaves Cat Part HDBL 15S/MH or equivalent of Havells/Philiphs.
S&F as in repairs street light bracket made of GI Pipe 40mm bore light grade 1.5 Mtr in length, bent to required shape fixed with 2 Set of MS Clamps made out of flat iron 40x4mm, incl bolts, nuts and washers complete all as specified and directed. Make of Pipe:- TATA/JINDAL /NIDHI
S&F as in repairs electric timer control panel, cubical type, for out door use, dust & vermin proof wall mounted made out of CRCA steel sheet with time switches type 63 Amps 3 pole, 230 Volt Analog time switch with complete accessories to fix on pole for switch on, off and control the street light timings including testing complete all as specified and directed. Make:- Havells Cat Part IHXSS01060 or eqivalent of L&T/Legrand/ABB.
All as per description of serial item No. 13 here in before but with 40 Amps 3 pole, 230 Volt Analog time switch all as specified and directed. Make:-Havells Cat Part IHXSS0312A or eqivalent of L&T/Legrand/ABB.
S&F as in repairs Junction box (Bus bar chamber box) of size 250mm x 200mm x 105mm made out of palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 2.5 Amp, 240 volts, 10 KA for controlling the street light fixed to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles,complete all as specified and directed. Make : Havells / LEGRAND / L&T / Crompton Greaves / Sytex / MECO / Brite
S&F as in repairs GI pipe 40 mm bore, light grade for cable protection fixed along the pole, with suitable size MS Clamps made out of 25x3mm thick flat iron including nuts bolts and washers complete all as specified and directed by Engineer in charge. Make:- TATA/JINDAL/ NIDHI
Re-stretching the existing LT overhead line of any size 3 phase 4 wire system (three phase,one neutral and one GI wire) including opening and re- connecting of jumpers, binding of conductor over the insulator properly with the help of binding wire and all conductors bracing with separator as required complete all as specified and directed. Note:- (i) Each conductor (phase / neutral) shall be measured separately for payment purpose. Cost of stretching of GI earth wire included in the unit rate of this item. (ii) T&P required shall be arranged by the ontractor at his own and the cost thereof shall be deemed included in the unit quoted rate.
Excavation in any type of soil in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches for laying of cable / pipes etc.and getting out, complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exc 25cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor Cross sectional area 50 Sqmm, 3.5 core from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
All as per description of item No. 21.00 here-in-before but Cross sectional area 25 sq mm, 4 core
All as per description of item No. 21.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core.
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 25 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing vompete all as specified and directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately.
All as per description of serial item No. 24.00 here in before but cross sectional area of cable 35 sqmm 3.5 core
All as per description of serial item No. 24.00 here in before but cross sectional area of cable 50 sqmm 3.5 core
M&L sand cushioning using dry and clean tibba sand in two layers, first laylers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ ducts including consolidation of each layers complete all as specified and directed.
Supply and laying in trenches, well burnt old size sub Class ‘B’ bricks, laid flat, abutting each other for cable protection complete all as specified and as directed.
M&L boring of road crossing of size 100mm dia at suitable depth by mechanically complete without damaging the surface for passing pipes / cables etc. including removing excavated soil to a distance n exc 50m complete all as specified and as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.
S&F as in repairs conventional LED street light 70 watt / 72 watt, 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver complete all as specified and as directed. Make :- Havells Cat Part ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent in Crompton/Bajaj/Surya
S&F as in repairs conventional LED street light 60 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver complete all as specified and as directed. Make:- Havells Cat Part ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Crompton/Bajaj/Surya
Supply and fix as in repairs LED street light 45 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver in replacement of conventional street light 70/125 watt SV/MV complete all as specified and directed. Make:- Havells Cat Part ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent in Crompton/Bajaj/Surya
S&F as in repairs conventional LED 70W flood light fitting with lense, high luminous efficacy,protected to IP 65, toughened glass efficient high out put emitter LED for better distribution applicable for area lighting including electrical connection complete all as specified and directed. make:- Havells Cat Part JETAPROFL70WLED757LTG or equivalent in Crompton/Bajaj/Surya.
S&F as in repairs Aviation light 2 x 100 watt fitting complete LED type doble with alternate flashing and dusk automatic control housing cast aluminium base with red diffuse lens complete all as specified and directed. Make :Bajaj Cat part No. BJAOL 2BC /Philips/Crompton/Havells.
Taking down defective LED flood light capacity 45/60/70 W any type from their existing position i.e poles and building and refixing the same after repairs such as replacement of LED driver connection cable etc. all as specified and directed. Note :- (i) Cost of repair is included in unit rate of this item. (ii) LED driver and PVC wire /cable shall be measured and paid separatly under respective items of BOQ.
Supply only LED driver for 45 watt LED flood light fitting complete all as specified and directed.Make : Havells/Crompton/Bajaj/Surya
Supply only LED driver for 60 watt LED flood light fitting complete all as specified and directed. Make : Havells/Crompton/Bajaj/Surya
Supply only LED driver for 70 watt LED flood light fitting complete all as specified and directed. Make : Havells/Crompton/Bajaj/Surya
Supply and fixing as in repairs LED traffic signal light combination of (Red/Amber/Green) made out of polycarbonate body suitable for extreme weather conditions operating temp between - 40ºC to 70ºC, water proof sealing between Lens and body, UV stabilized clean polycarbonate Lens, operating voltage 230 VAC, 12/24 VDC, IP 65, including complete with all fixing arrangement all as specified and directed. Make:-Trafitronics India pvt ltd/ Microtrans
M&L : repair to street panel board indoor / outdoor type of any capacity having Incomer & out going MCBs, timer switchand power contractor by carrying out the following works:- (i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by mechanichally. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing. (iii) Replacement of Incoming / out going switches as per existing make & model. (iv) Replacement of timer switch and cortractor as per existing make & model. (v) Replacement of control wiring with suitable size as per existing copper wire (vi) Making the locking arrangement functional including welding if required (vii) making proper connections for out going / incoming cable by providing suitable thimble as required. Note: MCBs, timer switch and contractor shall be measured and paid separatly as 'Supply only' against respective item of this Schedule..
Supply only following fixtures / fittings for replacement in LT Panel boards:-
MCB, 10 KA, SP, 32A. Make : CROMPTON, INDOASIAN, HAVELLS, L&T, LEGRAND,
MCB, 10 KA, SPN, 32A. Make : CROMPTON, INDOASIAN, HAVELLS, L&T, LEGRAND
MCB, 10 KA, TPN 63A. Make : CROMPTON, INDOASIAN, HAVELLS, L&T, LEGRAND
MCB, 10 KA, TPN 32A. Make : CROMPTON, INDOASIAN, HAVELLS, L&T, LEGRAND
Astronomical timer switch 240 volts Make : Havells Cat No DHTKW01016 or equivalent of make L&T / Legrand
Power contactor 70 Amp 4 pole 415 V 50 Hz model ML 4 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no SS90910 or equivalent of Make Havells / Crompton Greaves.
Power contactor 40 Amp 4 pole 415 V 50 Hz model ML 3 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no SS90721 or equivalent of Make Havells / Crompton Greaves.
Laying only XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 25 Sqmm, 4 core in trenches or fixed to wall /passing through pipe / pole and testing complete all as specified and directed. Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately, (ii) Old serviceable cable obtained by taking out shall be re-used.
All as per description of serial item No. 42.00 here in before but cross sectional area of cable 35 sqmm 3.5 core
All as per description of serial item No. 24.00 here in before but cross sectional area of cable 50 sqmm 3.5 core
Taking out AFLS multi-core cable from trenches / wall / poles / etc, shifting serviceable cable for relaying / depositing the unserviceable cable with AF authorities complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
Laying only AFLS multi-core cable in trenches or fixed to wall /passing through pipe / pole and testing complete all as specified and directed. Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately, (ii) Old serviceable cable obtained by taking out shall be re-used. In case, defective cable is required to be replaced, the cable shall be arranged by the AF authorities but transportation of the cable from AF Store to site of work near run way / taxi track shall be included in the unit quoted rate of this item.
S&F as in repairs line separator over head line with ACSR conductor system suitable for LT supply, 650 volt, 4 wire complete all as specified and directed. Note: (i) Before starting the work for this item, Contractor shall obtain prior written permission / shut down of power supply from AGE E/M. (ii) T&P required shall be arranged by the contractor and the cost thereof shall be deemed included in quoted unit rate of item.
All as per description of item No. 47.00 here in before but for 230 volts 2 wire system.
RBS ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .