Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.0 L+₹1.6 L (4.87%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹35.0 L+₹1.6 L (4.88%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹36.5 L+₹3.1 L (9.42%)Rejected-Finance KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹36.9 L+₹3.5 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | Mercury Ship Repairs Pvt Ltd L11 | nexa L8 | PEGASOS ENGINEER TRADERS L4 | SHRI MALLIKARJUN BATTERY AND ELECTRICAL WORKS L10 | sanjay prabhu L6 | OM SAI ELECTRICALS AND HARDWARES L9 | M/S. B G GAONKAR L5 | BRO TECH ELECTRICAL & ENGINEERING SOLUTION L1 | M/S. NAVEEN ENGINEERING & CO L7 | SRI GURUPRASAD INFRATECH L3 | HARSHITA MARINE SERVICES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old defective LT UG cables of any size including cable protection pre cast concrete cover / bricks from the trenches and keeping aside for reuse/disposal complete all as specified and directed. | 1,130 | RM | 50 ₹56,500 | 20 ₹22,600 | 10 ₹11,300 | 15 ₹16,950 | 12 ₹13,560 | 15 ₹16,950 | 15 ₹16,950 | 5 ₹5,650 Lowest | 10 ₹11,300 | 10 ₹11,300 | 10 ₹11,300 |
| 2.00 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed.
Note: Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid for separately. | 200 | RM | 900 ₹1,80,000 | 350 ₹70,000 | 210 ₹42,000 | 180 ₹36,000 | 130 ₹26,000 Lowest | 175 ₹35,000 | 190 ₹38,000 | 170 ₹34,000 | 190 ₹38,000 | 180 ₹36,000 | 190 ₹38,000 |
| 2.10 | Description all as per item No 2 here in before but cross sectional area 10 Sqmm 4 core | 200 | RM | 800 ₹1,60,000 | 250 ₹50,000 | 190 ₹38,000 | 150 ₹30,000 | 125 ₹25,000 | 150 ₹30,000 | 170 ₹34,000 | 160 ₹32,000 | 10 ₹2,000 Lowest | 150 ₹30,000 | 174 ₹34,800 |
| 2.20 | Description all as per item No 2 here in before but cross sectional area 25 Sqmm 4 core | 250 | RM | 700 ₹1,75,000 | 400 ₹1,00,000 | 250 ₹62,500 | 190 ₹47,500 | 175 ₹43,750 Lowest | 280 ₹70,000 | 240 ₹60,000 | 220 ₹55,000 | 240 ₹60,000 | 185 ₹46,250 | 249 ₹62,250 |
| 2.30 | Description all as per item No 2 here in before but cross sectional area 6 Sqmm 2 core | 200 | RM | 600 ₹1,20,000 | 230 ₹46,000 | 160 ₹32,000 | 80 ₹16,000 Lowest | 90 ₹18,000 | 125 ₹25,000 | 120 ₹24,000 | 120 ₹24,000 | 120 ₹24,000 | 100 ₹20,000 | 127 ₹25,400 |
| 3.00 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 10 Sqmm 2 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed.
Note: Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid for separately. | 280 | RM | 800 ₹2,24,000 | 230 ₹64,400 | 200 ₹56,000 | 120 ₹33,600 | 98 ₹27,440 | 135 ₹37,800 | 130 ₹36,400 | 120 ₹33,600 | 140 ₹39,200 | 85 ₹23,800 Lowest | 143 ₹40,040 |
| 4.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed. | 183.06 | Cum | 5,000 ₹9,15,300 | 450 ₹82,377 | 350 ₹64,071 | 325 ₹59,494.5 | 300 ₹54,918 | 250 ₹45,765 | 220 ₹40,273.2 | 360 ₹65,901.6 | 200 ₹36,612 Lowest | 350 ₹64,071 | 280 ₹51,256.8 |
| 5.00 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed. | 93.56 | Cum | 1,000 ₹93,560 | 100 ₹9,356 | 150 ₹14,034 | 110 ₹10,291.6 | 50 ₹4,678 Lowest | 80 ₹7,484.8 | 90 ₹8,420.4 | 120 ₹11,227.2 | 100 ₹9,356 | 119.01 ₹11,134.58 | 110 ₹10,291.6 |
| 6.00 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 89.5 | Cum | 1,000 ₹89,500 | 200 ₹17,900 | 300 ₹26,850 | 220 ₹19,690 | 120 ₹10,740 Lowest | 250 ₹22,375 | 190 ₹17,005 | 290 ₹25,955 | 200 ₹17,900 | 165.25 ₹14,789.88 | 260 ₹23,270 |
| 7.00 | Supply and spread dry sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I all as specified and directed.
Note:- Punned thickness of sand only shall be measured & paid. | 73.22 | Cum | 2,000 ₹1,46,440 | 1,000 ₹73,220 | 2,500 ₹1,83,050 | 1,500 ₹1,09,830 | 1,350 ₹98,847 | 1,200 ₹87,864 | 2,000 ₹1,46,440 | 1,600 ₹1,17,152 | 1,500 ₹1,09,830 | 650 ₹47,593 Lowest | 1,100 ₹80,542 |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
28 Feb 2026, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
REPAIR / MAINTENANCE OF STREET/ SECURITY LIGHT FITTINGS, SOLAR POWER STREET/ SECURITY LIGHTS, HIGH MAST LIGHTS, BASKET BALL GROUND LIGHTS AND CONNECTED WORKS AT SITE E AND NCHC AMDALLI UNDER GE (SB) KARWAR.
2026_MES_751350_1
8458/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE(SB)KARWAR
₹89,800
Yes
24 Apr 2026
7 Feb 2026
2 Mar 2026
7 Feb 2026
28 Feb 2026
21 Feb 2026
7 Feb 2026 - 13 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully old defective LT UG cables of any size including cable protection pre cast concrete cover / bricks from the trenches and keeping aside for reuse/disposal complete all as specified and directed. | 1,130 | RM | 1.25 | ₹1,412.5 |
| 2 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 16 Sqmm 4 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed.
Note: Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid for separately. | 200 | RM | - | - |
| 2.1 | Description all as per item No 2 here in before but cross sectional area 10 Sqmm 4 core | 200 | RM | 10 | ₹2,000 |
| 2.2 | Description all as per item No 2 here in before but cross sectional area 25 Sqmm 4 core | 250 | RM | 11 | ₹2,750 |
| 2.3 | Description all as per item No 2 here in before but cross sectional area 6 Sqmm 2 core | 200 | RM | 10 | ₹2,000 |
| 3 | Supply, laying, jointing and testing of LT underground XLPE insulated screened PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross-sectional area 10 Sqmm 2 core, conforming to IS-7098 (Part-I) of 1988 laid in trenches/wall/floors/ducts etc fixed with saddle and clamps or passing through pipes complete with cable and connection with proper thimbles, nuts, bolts and washers all as specified and directed.
Note: Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid for separately. | 280 | RM | 22 | ₹6,160 |
| 4 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed. | 183.06 | Cum | - | - |
| 5 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exceeding 25cm thick all as specified and directed. | 93.56 | Cum | - | - |
| 6 | Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 89.5 | Cum | - | - |
| 7 | Supply and spread dry sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I all as specified and directed.
Note:- Punned thickness of sand only shall be measured & paid. | 73.22 | Cum | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_841506.xls
BOQ • 0.35 MB
Tender8458.pdf
Tender Documents • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .