SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
SE, Sec-5, D, Vrindavan, Amausi Zone, Lucknow
54/SE(T)AMAUSI ZONE/2025-26
2026_MVVNL_1138208_1
54/SE(T)AMAUSI ZONE/2025-26
Open Tender
Electrical Works
Fixed-rate
365 days
LUCKNOW
As per Tender Document
2 documents required · 2 mandatory
₹3,540
E.E., EDD, CESS-Ist, LESA, Lucknow
₹31,000
29 Apr 2026
18 Apr 2026
29 Apr 2026
18 Apr 2026
29 Apr 2026
18 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1HV SIDE- Cleaning of dust, spider web, foreign particles etc, cleaning of all parts with cleaning agents such as CRC-226, check the tightness of all hardware, regressing as recommended, general checkup of relay megger testing, lubricating the operation mechanism setting and adjustment, general checkup of control circuit, operational test and relay trip test checking. LR/ACB Side-Cleaning of dust, spider web, foreign particles etc, cleaning of all parts with cleaning agents such as CRC-226, check the tightness of all hardware, regressing as recommended, general checkup of relay megger testing, lubricating the operation mechanism setting and adjustment, general check-up of control circuit, operational test and relay trip test checking. TRANSFORMER SIDE- Cleaning of dust, spider web, foreign particles etc, cleaning of all parts with cleaning agents such as CRC-226, check the tightness of all hardware, Oil filtration of transformer, BDV test of oil, general check-up of transformer protection relay, megger testing, P.I. testing and general check-up. | |||||
| 1.01 | Maintenance of Different make 11 KV CSS | - | Job | - | - |
| 2Supply and erection of ABB/Lucy/Schneider/ Other makes spare parts for 11 KV CSS (1000/800/750MVA) | |||||
| 2.01 | Spring Charging Motor | - | Nos. | - | - |
| 2.02 | Closing Coil | - | Nos | - | - |
| 2.03 | Trip Coil | - | Nos | - | - |
| 2.04 | Cable Root | - | Nos | - | - |
| 2.05 | LT MCB-250 A | - | Nos | - | - |
| 2.06 | LT MCB-400 A | - | Nos | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
TenderForm.pdf
Tender Documents • 1.62 MB
BOQ_2125276.xls
BOQ • 0.30 MB
AdditionalDocument.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .