Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC 1 23 10 ROJA FIRST STREET ALAMEEN NAGAR SURVEYOR COLONY MADURAI 625 007 | MADURAI | TAMIL NADU | 625007 | ₹4.2 L | L1 | Accepted-AOC Lowest Quoted |
| 2 | L2₹4.4 LRejected-Finance CHENNAI | ₹4.4 L | L2 | Rejected-Finance HIGHEST QUOTED |
| 3 | L3₹4.5 LRejected-Finance 9 A BALASUNDARAM LAYOUT 4TH STREET SINGANALLUR COIMBATORE 641005 | COIMBATORE | COIMBATORE | TAMIL NADU | 641005 | ₹4.5 L | L3 | Rejected-Finance HIGHEST QUOTED |
| 4 | L4₹4.8 LRejected-Finance | ₹4.8 L | L4 | Rejected-Finance HIGHEST QUOTED |
| 5 | L5₹7.1 LRejected-Finance | ₹7.1 L | L5 | Rejected-Finance HIGHEST QUOTED |
| Sl No | Description | Qty | Unit | GM ELECTRONICS L1 | micro mech instruments L2 | GLOBAL ENGINEERING EQUIPMENTS L5 | RK ENGINEERING L3 | DB MECH INSTRUMENTS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00Equipments/Machinery | ||||||||
| 1.01 | CLEVELAND OPEN CUP APPARATUS
As per IP 36, ASTM D92 and IS 1448 (P-69) Electrically heated model with energy regulator control. | 1 | No | 7,480 ₹8,826.40 | 11,000 ₹12,980 | 12,000 ₹14,160 | 21,800 ₹25,724 | 14,200 ₹16,756 |
| 1.02 | PENSKY MARTENS CLOSED CUP APPARATUS
As per IP 34 and IS 1448 (P-21) Electrically heated model with energy regulator control | 1 | No | 11,878 ₹14,016 | 11,000 ₹12,980 | 12,000 ₹14,160 | 21,800 ₹25,724 | 13,600 ₹16,048 |
| 1.03 | ORSAT APPARATUS
No. of tubes: 4 tubes, Mounting : table mounted, Four absorption pipettes of two compartment type ,100 ml Gas Burette with outer jacket, Four test manifold with stopcocks
Aspirator bottle, for the analysis of CO, O2, CO2 particularly in fuel and furnace gases,Calcium chloride tube and Rubber below
Absorption Pipette fitted with Glass tubes
Levelling bottle 250 ml. | 1 | No | 14,380 ₹16,968.40 | 61,200 ₹72,216 | 35,000 ₹41,300 | 31,500 ₹37,170 | 48,000 ₹56,640 |
| 1.04 | BOMB CALORIMETER WITH ALL ACCESSORIES
Temperature range:0-100oC,Differential temperature:0-10oC, Temperature accuracy:0.01oC,Measurement range : 1000-10000 Cal/gm, Firing Voltage:12V AC, Automatic Data storage type | 1 | No | 2,28,000 ₹2.7 L | 1,80,000 ₹2.1 L | 3,90,000 ₹4.6 L | 93,500 ₹1.1 L | 1,92,000 ₹2.3 L |
| 1.05 | SMOKE METER
Opacity : Range: 0-99.9 %, Resolution : 0.10 %, K-Value : Range: 9.99 m-1, Resolution : 0.01 m-1, Linearity : ± 0.1 m-1, Repeatability : ± 0.1 m-1, Zero & Span Drift: ± 0.1 m-1
Response Time: ˃ 0.4 Seconds (Physical), Response Time: ˃ 1 Millisecond (Electrical), Warm up time: ˃ 7 Minutes (@ 25º C and above), Engine RPM: 400 – 9990 RPM (Battery based)
Oil Temperature:0-150ºC,Operating Temperature:+ 5ºC to 50º C, Smoke Cell Measuring
Cell Length : 215 mm ( 430 mm folded Length)
Power Supply: 12 V DC ± 2V Battery
100 – 265 V AC, Single Phase,50-60 Hz
Power : 300 W AC/ 100 W DC (without heater)
Measures smoke opacity of diesel vehicles in % opacity and K value, Measurement principle : Partial flow, optics based on folded geometry,
Low & High voltage indication for battery operation,Automatic Zero and Span calibration, Automatic Pressure regulation and moisture separation, Handheld, Menu driven LCD remote control unit | 1 | No | 96,608 ₹1.1 L | 1,06,250 ₹1.3 L | 1,56,000 ₹1.8 L | 2,15,000 ₹2.5 L | 1,38,000 ₹1.6 L |
Tender Value
Refer Docs
EMD Value
₹1,800
Closing Date
26 Dec 2025, 5:00 pmClosed
The Principal,CPT,Tharamani
Principal,Central Polytechnic College,Tharamani
purchase of equipments/machinery
2025_DoTE_629219_1
4028/b4/2025
Open Tender
Machinery and Machining Tools
15 days
Principal, Central Polytechnic College, Tharamani
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1,800
Yes
6 Mar 2026
5 Dec 2025
29 Dec 2025
5 Dec 2025
26 Dec 2025
5 Dec 2025
CLEVELAND OPEN CUP APPARATUS As per IP 36, ASTM D92 and IS 1448 (P-69) Electrically heated model with energy regulator control.
PENSKY MARTENS CLOSED CUP APPARATUS As per IP 34 and IS 1448 (P-21) Electrically heated model with energy regulator control
ORSAT APPARATUS No. of tubes: 4 tubes, Mounting : table mounted, Four absorption pipettes of two compartment type ,100 ml Gas Burette with outer jacket, Four test manifold with stopcocks Aspirator bottle, for the analysis of CO, O2, CO2 particularly in fuel and furnace gases,Calcium chloride tube and Rubber below Absorption Pipette fitted with Glass tubes Levelling bottle 250 ml.
BOMB CALORIMETER WITH ALL ACCESSORIES Temperature range:0-100oC,Differential temperature:0-10oC, Temperature accuracy:0.01oC,Measurement range : 1000-10000 Cal/gm, Firing Voltage:12V AC, Automatic Data storage type
SMOKE METER Opacity : Range: 0-99.9 %, Resolution : 0.10 %, K-Value : Range: 9.99 m-1, Resolution : 0.01 m-1, Linearity : ± 0.1 m-1, Repeatability : ± 0.1 m-1, Zero & Span Drift: ± 0.1 m-1 Response Time: ˃ 0.4 Seconds (Physical), Response Time: ˃ 1 Millisecond (Electrical), Warm up time: ˃ 7 Minutes (@ 25º C and above), Engine RPM: 400 – 9990 RPM (Battery based) Oil Temperature:0-150ºC,Operating Temperature:+ 5ºC to 50º C, Smoke Cell Measuring Cell Length : 215 mm ( 430 mm folded Length) Power Supply: 12 V DC ± 2V Battery 100 – 265 V AC, Single Phase,50-60 Hz Power : 300 W AC/ 100 W DC (without heater) Measures smoke opacity of diesel vehicles in % opacity and K value, Measurement principle : Partial flow, optics based on folded geometry, Low & High voltage indication for battery operation,Automatic Zero and Span calibration, Automatic Pressure regulation and moisture separation, Handheld, Menu driven LCD remote control unit
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_752449.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid