Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹74.0 L+₹56,000 (0.76%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | Rejected-Technical DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | - | Rejected-Technical Due to non eligible category. | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to non eligible category. |
Tender Value
₹77.9 L
EMD Value
₹1.4 L
Closing Date
23 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WKS ENGRS
HQ 133 WKS ENGRS PIN-914133 C/O 56 APO
PROVN OF TRANSFORMS AND SPECIAL REPAIR TO DAMAGED UNSERVICEABLE HT OVER HEAD CONDUCTOR, INSULATOR, POLES, GOD OF 33 KV OVER HEAD LINE AT DIFFERENT LOCATIONS UNDER GE 874 EWS
2020_MES_340753_2
CWEK-06/2020-21
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE 874 EWS
Class C Category b (iii)
7 documents required · 7 mandatory
₹1,000
GE 874 EWS
₹1.4 L
Yes
HQ 133 WKS ENGRS
21 Aug 2020
19 May 2020
25 Jun 2020
19 May 2020
23 Jun 2020
9 Jun 2020
19 May 2020 - 28 May 2020
28 May 2020
60 days
Amount
Building And Other Works
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil
Excavation in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil, complete all as specified.
M&L Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified.
M&L for Walling of random rubble stone uncoursed, well bonded, bedded and solidly hearted, built in CM (1:6), complete all as specified and directed.
Spreading and levelling in layers not exc. 25cm thick and well ramming including watering the earth under floor, complete all as specified and directed.
M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface of broken stone or boulders.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed
Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span
Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc all as specified
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, Rough finished surfaces of concrete
Form work to soffits of suspended slabs such as roof slabs, floor slabs landing and similar work not exceeding 200 mm thick (Horizontal or sloping).
M&L 75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base under floor/path all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:4) laid over and including 25mm thick PCC (1:2;4) type B0 using (12.5mm graded crushed stone aggregate), complete all as specified and directed.
M&L Glazed ceramic coloured /printed tiles (300x200mm) x 6 to 7mm thick, as in vertical surfaces such as in skirting and dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 10 mm thick screed bedding layer in cement mortar 1:4 complete all as specified and directed.
M&L Rendering 10mm thick on fair faces of brick work or concrete surface, in cement mortar 1:4 finished the surface even and smooth without using extra cement , complete, all as specified and directed.
M&L Rendering 15mm thick on other than fair faces of brick work or stone masonry surfaces in cement mortar 1:4 using WPC @ 3% by weight of cement finished the surface even and smooth without using extra cement ,complete all as specified and directed.
Supply only Integral water proofing compound
4mm thick Sheet glass ordinary quality, glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and as directed.
Mild steel work in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 including painted one shop coat of zinc chromate primer paint.
S&F Prepainted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50mm thick of an colour as approved by GE as in roof covering etc all as specified
Preparation of steel surfaces of any description, over 10cm in width or girth, not otherwise described by treating with one coat of mordant solution to new galvanised steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for Three coats of white wash on newly plastered surfaces of wall including preparation of surfaces, complete all as specified and directed.
S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed
S&F 100 mm long aluminium anodised, barrel tower bolts of extruded section and fixed
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 75 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F 125mm long aluminium handles, cast type, anodised
S&F 100mm long aluminium handles, cast type, anodised
M&L for Vitreous china squatting pan “Orisa pattern” size 580x440mm white with incl flush pipe of PVC 32mm dia for low, level cistern all as specified.
S&F 10 Ltr Capicity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet,ball valve, float and handle including brackets
S & F Vitreous china urinal, bowl type flat back of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe
S&F 15mm bore stop valve, cast copper alloy, screwed down high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed ,complete all as specified and directed.
S&F 20mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed , all as specified and directed.
S&F 20mm dia Ball brass valves , high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed.
S&F 15mm bore Bib taps cast copper alloy with crutch or butter-fly handle screwed down, screwed for iron pipe or for brass ferrules, complete all as specified and directed.
M&L PVC (SWR) gully trap125/110mm set and jointed with solvent cement, complete all as specified and directed.
S&F 110/110 PVC(SWR) P trap
S&F PVC (SWR) pipe 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
S&F 110 x75 PVC (SWR) reducers
S&F for 110mm PVC (SWR) junction single (single T) equle or unequle with access door all as spd.
S&F 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per srl item 1.44 above but 6mm to 8mm dia as in stirrups
M&L for PVC (SWR) floor trap dia of outlet 75mm with grating incl jointing with solvent cement.
M&L 15mm Tubes, medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors
M&L 20mm Tubes, 'medium grade', galvanised, with all fitting; laid in trenches
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) and fixed in position, all as specified in SSR Part-I, complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20mm
S&F swivel shower of PTMT any colour for fixing with 15mm pipe etc all as specified.
S&F Vitreous China wash basin, white, flat back of size 550x 400 mm incl cutting for and pining, in ends of brackets or erecting stand etc.
S & F Pillar taps, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipes.
S&F waste fittings 32 mm bore, brass, chromium plated for basins etc with long screwed shanks and fly nuts, flange and bed deal in red lead cement and other end complete.
S&F 20mm dia D type towel rail 600mm long of brass CP fixed with and including CP brass screws complete.
S&F PVC grating 100mm dia fixed to floor trap.
Removing of excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
INTERNAL Electrification work
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area) single core flame retardant low smoke (FRLS) PVC insulated and unsheathed stranded cable 1100 volts grade ISI-694 marked TEC and FIA approved in and including medium grade , ISI marked PVC casing caping not less than 32 mm width , 10 mm depth with accessories fixed on wall/ceiling surface incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS) , 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with GI flush box , inner and outer plate as required for housing modular switch and socket as per module for one light/fan point controlled by one switch. Note :- GI flush box , inner and outer plate, Modular Switch, socket and fan regulators to be measured and paid for separately), complete, all as specified and directed. PVC Conduit confirming to IS 9537 part I & III
Description all as per Srl item No.2.01 here in before but for socket outlet point 5 Amp on Independent board complete, all as specified and as directed.
All as per the description of Serial Item No 2.01 above, but with 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size complete, all as specified and as directed . (Switch, Socket shall be measured and paid separately)
Supplying and fixing the ceiling rose, three terminal ISI marked surface backlit, complete all as specified and as directed.
Supply and fixing switch 6 Amps, one way, 230 volt , AC supply, ISI Marked, complete all as specified and as directed.
S & F of Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal colour matching with surounding universal complete all as specified and directed.
S & F of Switch socket combination 2 in 1, 3/5 pin, 6 Amp flush type universal colour matching with surounding universal complete all as specified and directed.
LED light fitting fixture 20W, 6500K, decorative ultra slim with extruded Al, heat sink, environmental friendly. energy efficient ready to use complete all as specified.
Exhaust fan heavy duty AC single phase 230 volts/240 volts 50 Hz of size 380 mm sweep, 1400 RPM, complete with louvers shutters and connecting up with suitable flexible cord wire with ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts in PCC 1:2:4 type B-1, complete all specified and directed.
MCB SPN 40 Amps, 240 Volts, 50 Hz AC supply 'C' series, 10 KA breaking capacity complete all as specified.
MCB SP 6 to 32 Amps, 240 Volts, 50 Hz AC supply 'C' series, 10 KA breaking capacity complete all as specified.
Supply, fixing and testing storage water heater 25 litre capacity vertical mounted, AC 230 volts including connecting cord and plug, safety valve, nuts and bolts, CP connections, including grouting bolts and pvc connection of size 15mm dia and 900mm long for hot water with brass nuts both end complete all as specified and directed.
Sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with 200 Amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular size of 10 Sqmm complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Electrification work
Supply and fix HT OH lines on Existing Poles with ACSR conductor of size 3 of 6/1x3.00 mm (Ferret).Including Taking down Old Unsv ACSR Conductor complete all as specified and directed.
S & F of Supply and erecting in vertical position steel tubular swaged pole type 410 SP - 55 (12 Mtr) with 300mmmX300mmX6mm mild steel baseplate continuously welded to pole final taper, nuts, bolts, and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeddedprotion and applying one coat of red oxide primer for the remaining protion an two coats of aluminium paint beyound 1.5 M from ground level/coping and making 30cm black and white strips with two coats of super enmeled paint upto 1.5 M from ground level/Coping including taking down old existing unserviceable HT pole and removing away complete all as specified and directed.
Supply and fix Pin type, Silicon Polumer insulator including two galvanised iron washers and one galvanised iron nut, sectional length 375mm with complete fixing arrangements on pole for 33KV volts grade Including taking down old Unsv complete all as specified and directed.
Supply and fix Disc type insulator, Silicon Polymer ball and socket type, white assembly for tension with tension clamps for conductors, related mechanical tension load 70KN, sectional length 510mm, working pressure 33KV to 36KV volts white complete fixing arrangements on pole complete Including taking down old Unsv all as specified and directed.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 120 sq mm Including taking down old Unsv complete all as specified and directed.
Supply and fix cable jointing kit for 33 KV grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 to 120 sq mm .
Taking down old unsv/broken 33 KV Isolator and M&L for rotating isolator triple pole double break capacity 33KV 630A 25 KA rotating type with earth switch gang operated outdoor having each pole has galvanised steel base, solid core or post type insulators, EC grade copper fix and moving contacts, GI coupling pipe of adequate length for rotating operation from ground level and operating handle for smooth operation, ferrous parts are hot dip galvanized and non ferrous parts are heavily tinned to withstand weather. The handle fabricated from channel, lever and turned pipe gripper with locking arrangement in both ON and OFF position all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing on completion, all as specified and directed.
Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, including taking down unserviceable/old cross arms, complete all as specified and directed.
Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 2.00m in depth for foundation of pole, stay assembly as in any type of soil and getting out complete all as specified and directed.
All as per Srl item No.3.10 above but in depth exce. 1.5mtr to not exce. 3 mtr.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles, filling & mass concrete complete all as specified and directed.
PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in coping of poles with & including necessary formwork complete all as specified and directed.
Supply, installing, testing and commissioning outdoor type, 4 pole mounted step down transformer, 11 KV/415 Volts (at full load) AC 3 phase 50 Hz, 200 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at + 2.5% & + 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Celsius. The transformer shall be BEE star rated as per IS 1180 complete all as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning outdoor type, 4 pole mounted step down transformer, 11 KV/415 Volts (at full load) AC 3 phase 50 Hz, 100KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at + 2.5% & + 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Celsius. The transformer shall be BEE star rated as per IS 1180 and be provided with suitable overhead Galvalum Sheeted roof for rain protection. The transformer shall have atleast 24 months (working period) of warranty.
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 200 KVA
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 100 KVA including bypass arrangement. The transformer shall have atleast 24 months (working period) of warranty.
S & F and erecting in vertical position steel tubular swaged pole type 410 SP - 55 (11 Mtr) with 300mmmX300mmX6mm mild steel baseplate continuously welded to pole final taper, nuts, bolts, and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeddedprotion and applying one coat of red oxide primer for the remaining protion an two coats of aluminium paint beyound 1.5 M from ground level/coping and making 30cm black and white strips with two coats of super enmeled paint upto 1.5 M from ground level/Coping.
Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, horizonal mounting type (ISI marked), mechanically operated, mounted on insulators including 200 amp rating complete with fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections, complete all as specified and directed by Engr-in-Charge
M & L for 80 mm bore Galvanised steel tubing light grade for protection of under ground cable on poles / walls under road crossing etc conforming to IS-1239 complete all as specified and directed by Engr-in-Charge.
M & L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanized earth lead GI strip 25x4mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe medium grade 40 mm bore for protection of GI strip and connected to continuous earth lead on pole/test point supply and laying charcoal dust common salt PCC 1:2:4 type B-1, chamber and MS angle iron frame 40x40x 3mm and RCC cover 40 mm thick(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia PGI funnel and wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point incl testing complete all as specified and directed. Note:- The cost of earth lead/strip and GI pipe for protection of earth lead/strip upto 7.5 M is included in the quoted rate.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles of sizes 95 Sqmm 3.5 core.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles of sizes 120 Sqmm 3.5 core.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 11000 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles of sizes 95 Sqmm 3 core.
Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 11000 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles of sizes 240 Sqmm 3.5 core.
M&L for sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and as directed by Engr-in-Charge
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified and directed.
M & L for Danger notice plate of 1.6mm thick mild steel, vitreous enamelled white, with letter, figures and conventional skull bones in signal red colour and fixed with mild steel clmaps, nuts, bolts and washer clamps made out of 25x3mm flat iron for LT/HT poles/transformers/pillar box etc with voltage and danger indicated in Hindi and English complete all as specified and directed of size 25x20cm.
M&L Lightening arrestor metal di-oxide type complete with all fitting, transmission class, discharge capacity 65 KA, 11KV voltage grade
(b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 200 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 01 No (ii) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 02 Nos (iii) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 10 KA rupturing capacity complete with microprocessor based OL, protection - 02 Nos (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Note :-(i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(b) Outgoing (i) MCCB 4 pole, 415 volts AC grade, 100 Amps rating and 36 KA rupturing capacity complete with microprocessor based OL protection - 02 Nos (ii) MCCB 4 pole, 415 volts AC grade, 63 Amps rating and 10 KA rupturing capacity complete with microprocessor based OL, protection - 02 Nos (c) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level.
Supply, installing, testing and commissioning, factory made and tested (prototype having been CPRI type test certified), 11 KV Trivector smart energy meter 3 phase 4 wire with GPRS capability and display page consisting 3 phase voltages, current, KVA, frequency demand parameters, MD histories, clock, calendar, demand profile, predective demand and additional load capacity, TOD demand (8 zones) with suitable CT-PT combination and meter reading instrument (with Base computer software for graphical analysis), of Make Secure, L&T or Havells Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
M/S Khan Hussain & Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .