| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.8 L+₹1.2 L (3.15%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate. | |
| 3 | L3₹42.9 L+₹5.3 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate. | |
| 4 | L4₹45.0 L+₹7.4 L (19.7%)Rejected-Finance 00 ITBAHRA GAUR KANIKAPUR ROAD KANIKAPUR BASTI UTTAR PRADESH 272163 | BASTI | UTTAR PRADESH | 272163 | L4 | Rejected-Finance Quoted other than lowest rate. | |
| 5 | L5₹45.5 L+₹7.9 L (20.9%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L5 | Rejected-Finance Quoted other than lowest rate. |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
4 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR, EE, IDSE
GE NORTH BATHINDA Pin-151004
SPL REPAIR OF SEWAGE LINE WITH CHAMBER IN OTM -04, REGT AND PROVN OF TOILET IN OFFICE COMPLEX BESIDE BLDG NO 743 UNDER AGE B/R- V AND AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
2024_MES_644536_1
8938/NIT-78/23-24
Open Tender
Civil Works
Item Rate
180 days
BATHINDA
Class D Category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹97,000
Yes
25 Jul 2024
29 Feb 2024
6 May 2024
29 Feb 2024
4 May 2024
20 Apr 2024
29 Feb 2024 - 6 Mar 2024
Amount
B/R Works
Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide & not exceeding 1.5 metre in depth, and not exceeding 10.00 sqm on plan, for foundations of manholes, sewerage pipe lines etc including getting out complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No 1.00 here-in-before but exceeding 1.5 metre and not exceeding 3.00 metre in depth. complete all as specified and as directed by Engineer-in-Charge.
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and incl 150 mm bore pipes all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes SGSW, AC or reinforced concrete pipe up to and incl 300 mm bore pipes all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) to drain pipe incl packing under & haunching against the sides of pipe 150 mm dia (internal) after the pipes are laid and tested in trenches complete all as specified and directed.
Material & labour for PCC 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) to drain pipe incl packing under & haunching against the sides of pipe 300 mm dia (internal) after the pipes are laid and tested in trenches complete all as specified and directed.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. Note : Excavation & earth work and concrete bed shall be measured and paid separately under appropriate item of BOQ.
Material and labour for 300mm bore reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and directed by Engr-in-charge. Note : Excavation & earth work and concrete bed shall be measured and paid separately under appropriate item of BOQ.
Demolition of brick work built in cement mortar including all quoins, pillars etc., but excluding pre-cast cement concrete articles complete all as specified and as directed by Engineer-in-Charge .
Material & labour for cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) for foundations, fillings & mass concrete complete all as specified and as directed by Engineer-in-charge.
Material & labour for cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) for foundations, filling & mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ bricks old size, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge .
Material and labour brick work with sub class ‘B’ bricks old size, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge .
Material and labour for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) but except bricks (old serviceable bricks shall be used for incorporation in work after cleaning) complete all as specified and as directed by Engineer-in- charge. Note :- The rate of cleaning of old bricks is included in this item and nothing shall be paid extra on this account.
Material and labour for cement concrete 1:2:4, type B-0, (using 12.50 mm graded stone aggregates) as in bands, bedding, benching of manholes, coping, surface channel, roof kerbs or mud stops, rounded or chamfered on edges etc including use & waste of necessary form work complete all as specified and as directed by Engineer-in-charge.
Material & labour for 15 mm thick cement plaster in cement mortar 1:4 on fair / unfair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
Material & labour pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in pre-cast manhole cover slabs of any thickness, size or shape including use & waste of all necessary form work, finishing concrete surface fair & even and set in cement mortar 1:4 all as specified and directed by Engineer-in-Charge.
Supply and fixing in position TMT bars of 10 mm dia and over in reinforcement, cut to length, bend to shape required including cranking, bending, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed by Engineer-in-Charge.
Supply and fixing in position TMT bars of 6 mm to 8mm dia in reinforcement, cut to length, bend to shape required including cranking, bending, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed by Engineer-in-Charge.
Supply and fixing mild steel work in rungs, hooks, handles, manhole covers, hold fast & small articles all as specified and directed.
Returning, filling in including spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick each all as specified and as directed by Engineer-in-Charge.
Removal of excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing powder complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation (size of cover 0.70 x 0.70 or as directed by Engineer-in-Charge) conforming to IS-12592, fixed in cement concrete 1:2:4. complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4, type B-2 (using 40mm graded crushed stone aggreagate) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Cutting into existing manhole for connecting new drain pipe of 150 mm bore and making good the pipe and rendering disturbed surface where drain pipe have been inserted cutting out existing benching for forming branch channel (1/2 round or 3/4 round as required) in cement concrete 1:2:4 type B1 and finished the surface even and smooth and reforming benching as required and directed by Engineer - in - Charge.
Removing of manhole cover (CI or RCC) for opening of septic tank or sewage wells (any type rectangular or circular) of any size and capacity in foul condition and bailing out muddy water, taking out semi solid sludge/solid contents/night soil from tank by mechanically by sewage suction pump making it fully functional and cleaning the internal surfaces with water to the entire satisfaction of Engr-in-Charge incl all necessary tools and plants required for removal of all wastages, solid or liquid sludge from the site through closed container and depositing the sludge in a pit (at empty/open area) of suitable size at any distance upto 200m from the line/colony area where directed and covering the same with the soil obtined from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earth work and refixing the manhole cover to its original position complete all as specified and directed by Engr-in-Charge Note :- (i) All the tools and plants including mechanical pump, closed lorry and other allied arrangements for making septic tank clean and functional will be made available by the contractor without any extra cost to the Govt.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes, if any, and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.
Material and labour for 100mm thick cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
Material and labour for machine pressed precast interlocking paver block 60 mm thick with grey cement and no pigment, factory made, any shape and size (as approved by GE) conforming to IS 15658-2006, M-35 grade concrete, laid over and including 25 mm thick layer of sand cushioning complete all as specified and as directed by Engineer-in- charge. Note: The rate of 25mm thick layer of sand cushioning is included in this item and nothing shall be paid extra on this account.
Material and labour cement concrete 1:3:6 type C-1, (using 20mm graded stone aggregate) as in copings, packing around interlocking paver blocks complete all as specified and as directed.
Material and labour for precast cement concrete (1:2:4) type B-1(using 20 mm graded stone aggregate) in kerb stone, quion block, apex stones etc set in cement mortar (1:4) including use & waste of necessary form work, weathering, slightly rounded or chamfered angles and throating all as specifed and directed.
Material and labour for preparation of new or previously treated/untreated concrete surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint in different tint complete all as specified and as directed by Engineer-in- charge.
Material and labour for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius, in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Material and labour for 40 mm thick damp proof course in cement concrete 1:2:4, type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including use & waste of necessary form work and including mixing of WPC in concrete complete all as specified and as directed by Engineer-in- charge. Note :- WPC shall be measured & paid separately as Supply only
Use and waste of form work to sides and soffits of floor or roof beams, haunchings, girders, bressummers, lintels, chajjas, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc. complete all as specified and directed.
Use and waste of form work to fair finished soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
Use and waste of form work to chullah, chajjas, troughs and similar items including edges/sides, fair finished complete all as specified.
Material and labour for reinforced cement concrete 1:2:4, type B-0 (using 12.5 mm graded aggregate) as in beams, cantilevers, bressummers, chajjas, plinth beam, lintels over 1.5m span complete all as specified and directed.
Material and labour for reinforced cement concrete 1:2:4 (nominal mix), type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge.
Material and labour for rendering 5 mm thick in cement mortar 1:3 on brick work or concrete surfaces as in ceiling finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even & fair faces without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick work or cement concrete surfaces using water proofing compound @ 3% by weight of cement including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note :- WPC shall be measured and paid separately.
Material and labour for 75 mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) in plinth protection, aprons, hard standing, path and like including finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar 1:3 mixing with WPC on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surface complete all as specified and as directed. Note : WPC shall be measured separately
Material and labour for provn of water proofing roof treatment to accessible/Non accessible RCC roof with 3 mm APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal insulation with white mineral/ gravel finish on upper side of membrane uniformely embedded during manufacturing process all as per following specifications: (a) The surface of roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimneystacs etc. and other similar situations to ease up about corners. (b) Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied an prepared surface till the surface is properly impregnated. (c) APP modified water proofing membrene as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
Material and labour for moorum/red bajri filling in floors or pavings, laid in layers not exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
Material and labour for hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for cement concrete flooring 25 mm thick levelling course PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) finished even and rough to receive tiles complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles 7 to 8 mm thick, square or rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ per sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for glazed ceramic coloured tiles of size 300mmx 200mm / 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry @ 3.00 Kg/ per sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for granite (any type) 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, counter, shelves, urinal partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar 1:4 and moulding/rounding on edges by grinding complete all as specified and directed.
Supply & fixing vitreous china wash hand basin, oval type, under counter, white colour, of size 410mm x 310mm x 220mm excluding pillar taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ.
Supply & fixing vitreous china urinal of size 410x380x950mm, half stall type white, with grating and union for discharge pipe (excluding flushing cistern and flush pipe ) including CP urinal spreader and CP connection and waste pipe complete all as specified and directed.
Supply and fixing one piece (single unit EWC with flush tank) white colour with all fittings including seat cover, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade, 15mm bore with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade, 20mm bore with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to edges of landing, steps, cills, sunshades, shelves, lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified.
Supply and fixing fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for 15mm bore dia of pipe complete all as specified and as directed by Engineer-in-charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stainless steel, chromium plated, decorative type, soap dish holder of approximate size 160 x 160 x 90 mm fixed to wall with rubber plugs complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing tubular towel rail brass chromium plated 20 mm dia ‘D’ type 60 cm long including end brackets complete all as specified and as directed by Engineer-in-charge.
Supply and fixing PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified & directed.
Supply and fixing 15 mm pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Supply and fixing fancy type chromium plated stop/angle valve for 15 mm bore dia of pipe, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Supply and fixing chromium plated jet sprey/ (health faucet) for EWC incl 1 mtr long 8mm dia flexible tube and wall hook complete all as specified.
Supply and fixing 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls/ laid in trenches/floors with fittings complete all as specified and directed.
Supply and fixing PVC (SWR) bends any radius 110 mm dia complete all as specified and directed.
Supply and fixing PVC (SWR) pipe 75mm bore size for rain water pipe conforming to IS : 1984, incl standard PVC clamp & imbedded in PCC block incl jointing of pipes complete all as specified & directed by Engr-in-Charge.
Supply and fixing PVC bends 75 mm bore any radius complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 75mm bore PVC (SWR) vent cowl, complete all as specified.
Material and fixing for 75mm bore PVC (SWR) multi-floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, square or round type P or S trap complete all as specified and directed.
Supply and fixing stainless steel grating doom 100mm dia (min weight 25gms) complete as specified and directed.
Supply and fixing Solid PVC door frame of size 50 mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per manufacturer's instructions complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site as per specification & drawing complete all as specified and directed.
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, with one shop coat of zinc chromate primer, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
Supply & fixing stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply and fixing aluminium anodised handles, 125 mm long, cast type, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 200 mm aluminium anodised barrel tower bolts extruded section and fixed complete all as specified and directed.
Supply and fixing SS butt hinges 100 mm, medium weight, cold rolled complete all as specified and directed.
Material and labour for Anti- termite treatment, treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in-charge.
Material and labour for Anti- termite treatment, treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by Engineer-in-charge.
Material and labour for Anti- termite treatment, treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engineer-in-charge.
Material and labour for Anti- termite treatment, treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (washable) over a coat of alkali resistant priming paint on plastered surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for applying three coats of white wash on newly plastered or unplastered ceiling surfaces including preparation of surfaces, complete all as specified and as directed by Engineer-in-charge.
Material and labour for preparation of new decorated surfaces (plastered/ unplastered) of walls/pillars /cornices upto entire satisfaction of Engineer-in-charge and applying two coats of weather proof exterior emulsion paint by using paint roller brush, as per approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
E/M Works
Material and labour for point wiring for one light/fan/5 Amps independent socket point/call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid conduit, heavy duty (ISI marked) terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified. Note : (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
All as per item No 93.00 here in above but for 5 Amp socket outlet on same board
All as per item No 93.00 here-in-before but for multi 5 pin socket outlet 5 amp socket on independent board
All as per item No 93.00 here-in-before but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 sqmm copper conductor multistrand cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia/bore heavy duty (ISI marked) and unsheathed copper conductor multistrand cable 1.5 sqmm as earth wire FRLS PVC insulated in green color all as directed by Engr-in-Charge.
Supply and fixing distribution board sheet steel phosphatised powder coated for MCB with copper bus bar and neutral link earthing stud SPN, 4 way, 240 Volts, double door complete all as directed by Engr-in-Charge.
Supply and fixing MCB SP, 6 to 32 Amps, 240 Volts, 'B' Series
Supply and fixing MCB SPN, 32 Amps 240 Volts, 'B' series complete all as specified
Supply and fixing switch piano, flush type, single pole, one way, 5 Amp, 240 Volts all as specified .
Supply and fixing socket outlet, 5 Amps, 5 pin, flush type complete all as directed.
Supply and fixing ceiling rose, 3 terminal, surface type complete all as directed.
Supply and fixing lamp holder, insulated body, with back plate suitable for batten fittings complete all as directed.
Supply and fixing self ballast LED retrofit lamp with PVC body and PC diffuser 9 Watt, 230 Volts, 6500K complete all as directed.
Supply and fixing new generation energy saving, wall mounted LED tube light fittings, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED duly fitted on PVC square block 6500K (4' ft long) with LED rod 20 Watt, 230 Volts 50 Hz complete all as directed.
Supply and fixing LED street light fitting 35 Watt 230 Volts AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600x600x6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover 10mm thick hinged to CI frame, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate), including necessary form work, excavation and earth work in any type of soil, returning, filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I), complete all as specified and and as directed by Engineer-in-charge.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 V grade cross sectional area 16 Sqmm, 2 core complete all as specified and and as directed by Engineer-in-charge.
Making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls including plastering for making good to the original surfaces of any description disturbed including painting /distemper matching with the existing colour complete all as specified and and as directed by Engineer-in-charge.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300 mm complete all as specified and and as directed by Engineer-in-charge.
K L JINDAL AND CO.
BALAJI CONSTRUCTIONS
M K Enterprises
V K CONTRACTOR
M/s MITTAL CONSTRUCTIONS
SAPNA BUILDERS
M/s PANKAJ KUMAR
R K GOYAL & COMPANY
N.G BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .