Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Work awarded to L1 bidder. |
Tender Value
₹4.0 L
EMD Value
₹8,050
Closing Date
17 Jun 2019, 6:00 pmClosed
AGM (E-E)
S.V. Airport, Raipur Engineering Electrical Department
Construction of Temporary MT Pool at S. V. Airport, Raipur. SH Provision of Electrical Works.
2019_AAI_26494_1
AAI/RPR/ENGG(E E)/CW/ENIT 08/2019 20
Open Tender
Electrical Works
Works
30 days
S.V. Airport, Ripur
As mentioned in NIT criteria.
5 documents required · 5 mandatory
₹1,120
Airports Authority of India
₹8,050
1 Sept 2020
24 May 2019
21 Jun 2019
25 May 2019
17 Jun 2019
25 May 2019
25 May 2019 - 17 Jun 2019
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C
Wiring for light/ power plug with 4X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supply of 450 mm sweep wall fan having Aerodynamically designed, Balanced Blade, thermal overload protection with 120 Ribs guard for safety, Jerk free oscillation (60o) & smooth running, 1400 RPM suitable for use on 230 volts, 50 Hz, single phase, A.C. supply etc. complete as required. (Make:- Havells, Model - V3 or equivalent).
Supply of 1440 RPM mm dia. 450 mm dia. heavy duty pedastal fans having 112 spokes with aerodynamically desined blades, Sturdy close mesh guards with powder coating, Double ball bearings etc. complete as required, suitable for 230 volts, 50 Hz, single phase, A.C. supply.
Supply of single phase 900 RPM, 300mm dia sweep Heavy Exhaust fan having Dynamically balanced impellers, Pre lubricated double ball bearings, Aluminium pressure die cast motor shell, Energy Efficient motor, with Louver and shutter/Guard, etc. complete as required suitable for use on 230 volts, 50 Hz, single phase, A.C. supply.
Supply of indoor surface mounting 20 W (nominal capacity), 1200 mm length LED light fitting efficacy of not less than 100 lumens, complete with LED tube rod, accessories etc and suitable for use on 230 volts, 50 Hz, single phase, A.C. supply as required. (Make:- Havells, Model - LHEXBXPNIN1W020, 6000 K or equivalent).
Supply of 30 W (nominal capacity) LED integral Flood Light type light fitting having pressure die cast housing with toughened glass, individual LEDs with secondary optics, IP 66, inbuilt convertor, accessories etc and suitable for use on 230 volts, 50 Hz, single phase, A.C. supply as required. (Make:- Havells, Model - JETACOMPECTOFL30WLED757TG or equivalent).
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (a) 8 way (4 + 24), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 100 A, 30 KA, Four Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) Triple Pole
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting/wall fan, complete with all accessories including connections etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (a) Upto 450 mm sweep
Supply of following sizes LT power cable of 1.1 KV grade of following sizes aluminum conductor XLPE insulated PVC sheathed armored cable confirming to IS 5554 & 7098/1/1988 with upto date amendment as required. (a) 3.5 x 35 Sqmm
Supply of following sizes LT power cable of 1.1 KV grade of following sizes aluminum conductor XLPE insulated PVC sheathed armored cable confirming to IS 5554 & 7098/1/1988 with upto date amendment as required. (b) 3 x 6 Sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (a) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1 mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (a) 3.5 x 35 Sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (b) 3 x 6 Sqmm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
Supply of 1.5 TR (Nominal) Hi-Wall type Split Air conditioner 5 star BEE rating fitted with hermetically sealed rotary compressor operating on refrigerant R-32/Non CFC, minimum cooling capacity (Kcal/Hr) : 4500, Power Consumption (Max): 1500W with cleanable filters, cordless remote & all accessories supplied with the unit by OEM etc suitable for operation on 1 Ph, 230V, 50 Hz single phase AC supply.
Installation, Testing & commissioning of A/C units as mentioned in item no-1 which includes mounting of indoor & outdoor unit including supply and fixing of MS stand at their respective location along with laying of refrigerant pipeline with insulation & flexible PVC covering pipe up to standard length supplied with the unit , connecting both the units , leak testing of entire system, connecting both indoor and outdoor units with three core 2.5 sq mm PVC insulated flexible copper cable supplied with the unit , top up of refrigerant (if required), minor civil repairing work as per site requirement complete as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .