Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being lowest and reasonable bidder | |
| 2 | L2₹6.5 L+₹24,980 (4.00%)Rejected-Finance 03 UTKARSH UMANG APARTMENT NEAR MT CARMEL SCHOOL WARDHA ROAD NAGPUR SUNIL KOLHE 03 UTKARSH UMANG APRT NEAR MOUNT CARMEL SCHOOL AJNI SQUARE 712 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹6.5 L+₹27,670 (4.43%)Rejected-Finance 142 JAGJIVANRAM NAGAR GAROBA MAIDAN NAGPUR 440008 | NAGPUR | NAGPUR | MAHARASHTRA | 440008 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹6.7 L+₹46,335 (7.42%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | ESKIMO COOL WORLD L2 | VIJ ASSOCIATES L4 | karambir constructions L3 | Shri Sai Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | S & F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed. | 10 | Each | 600 ₹6,000 | 625 ₹6,250 | 250 ₹2,500 | 175 ₹1,750 Lowest |
| 2.00 | S & F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified and directed. | 10 | Each | 850 ₹8,500 Lowest | 870 ₹8,700 | 1,500 ₹15,000 | 1,000 ₹10,000 |
| 3.00 | S & F in replacement metal clad plug two pin and earth complete all as specified and directed. | 14 | Each | 950 ₹13,300 | 990 ₹13,860 | 150 ₹2,100 Lowest | 300 ₹4,200 |
| 4.00 | M &L for sub main wiring with 2 run of 4 Sqmm (Nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (Nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. | 100 | RM | 435 ₹43,500 | 485 ₹48,500 | 200 ₹20,000 Lowest | 275 ₹27,500 |
| 5.00 | Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 1.5 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed. | 4 | Each | 12,500 ₹50,000 | 12,400 ₹49,600 Lowest | 14,000 ₹56,000 | 13,000 ₹52,000 |
| 6.00 | Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 2 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed. | 4 | Each | 13,500 ₹54,000 Lowest | 13,600 ₹54,400 | 15,000 ₹60,000 | 15,000 ₹60,000 |
| 7.00 | All as per item No. 5.00 here in before but suitable for refrigerator 180 to 310 ltrs capacity. | 1 | Each | 4,500 ₹4,500 Lowest | 5,000 ₹5,000 | 6,200 ₹6,200 | 5,500 ₹5,500 |
| 8.00 | All as per item No.5.00 here in before but suitable for Deep freezer for 320 ltrs capacity. | 1 | Each | 5,000 ₹5,000 Lowest | 5,000 ₹5,000 Lowest | 6,200 ₹6,200 | 7,000 ₹7,000 |
| 9.00 | All as per item No. 5.00 here in before but suitable for Water cooler 80/40 capacity.
Note for Sl item No 5.00 to 9.00: - Rate deemed to be inclusive of filling/Gas charging. | 1 | Each | 5,500 ₹5,500 | 5,500 ₹5,500 | 5,800 ₹5,800 | 5,000 ₹5,000 Lowest |
| 10.00Repair to voltage stabilizer for automatic low and high voltage correction boost / buck transformer by rewinding the transformer coil, replacement of selector switch, PC board, time relay, indicator lamp and three core cable cord with plug top and voltmeter for the following sizes: - | |||||||
Tender Value
₹6.3 L
EMD Value
₹12,500
Closing Date
2 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wing AF Station Sonegaon, Nagpur 440005
REPAIR / MAINT OF SUMMER AND COOLING APPLIANCES IN TXR AND TECHNICAL AREA AT AF STN SONEGAON NAGPUR
2025_MES_732648_2
8565/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Sonegaon
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Sonegaon
₹12,500
Yes
10 Mar 2026
20 Jan 2026
6 Feb 2026
20 Jan 2026
2 Feb 2026
27 Jan 2026
20 Jan 2026 - 26 Jan 2026
S & F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed.
S & F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified and directed.
S & F in replacement metal clad plug two pin and earth complete all as specified and directed.
M &L for sub main wiring with 2 run of 4 Sqmm (Nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (Nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed.
Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 1.5 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed.
Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 2 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed.
All as per item No. 5.00 here in before but suitable for refrigerator 180 to 310 ltrs capacity.
All as per item No.5.00 here in before but suitable for Deep freezer for 320 ltrs capacity.
All as per item No. 5.00 here in before but suitable for Water cooler 80/40 capacity. Note for Sl item No 5.00 to 9.00: - Rate deemed to be inclusive of filling/Gas charging.
Voltage Stabilizer 5 KVA capacity
Voltage Stabilizer 3/4 KVA capacity
Voltage Stabilizer 01 KVA capacity
S & F in replacement PCB (Printed circuit board) suitable for 1.5/2.0 Ton of split type Air conditioners complete all as specified and as directed.
M & L for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R- 410A/ R-22, R-32 for AC capacity 1.5/2 TR Split Type Air conditioner complete all as specified and as directed.
Material and labour for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R-12 /R-134 for following cooling appliances.
Refrigerator
Water Cooler
Deep freezer
S & F for Rigid PVC flexible hose of 15 mm dia 2.5 mtr length with all accessories fixed on wall /ceiling/ roof etc with suitable GI saddles and screws for connect with split type AC/water cooler as drain pipe complete all as per specified and as directed.
Supply and replace with new fan leaf unit suitable for Air conditioner of capacity 1.5TR/2 TR complete all as specified and directed.
Supply and replace with new remote control unit suitable for Air conditioner complete all as specified and as directed.
Supply and replace with new condenser coil unit made of copper suitable for the following capacity split Air conditioner complete all as per specified and as directed.
1.5 ton capacity
2.0 ton capacity
Supply and fix in repair Starting capacitors for following cooling appliances: -
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Running capacitors for following cooling appliances: -
Split type Air Conditioner 1.5/2/3 TR
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Thermostatic switch for following cooling appliances: -
Split type Air Conditioner
Refrigerator
Deep Freezer
Water Cooler
Supply and fix in repair Fan Motor for following cooling appliances: -
Split type Air Conditioner (Outdoor)
Refrigerator
Deep Freezer
Water Cooler
S & F in repair indoor unit blower Fan Motor for 1.5/2 Ton Split type Air conditioner complete all as specified and as directed.
S & F in replacement suction valve 1.5/2 TR capacity split type Air conditioner complete all as specified and as directed.
S & F in replacement discharge valve 1.5/2 TR capacity split type Air conditioner complete all as specified and as directed.
S & F in replacement flare nut of size 5/8 inch complete all as specified and as directed.
S & F in replacement flare nut of size 1/2 inch complete all as specified and as directed.
S & F in replacement flare nut of size 1/4 inch complete all as specified and as directed.
S & F in replacement flare nut of size 3/8 inch complete all as specified and as directed.
S & F in replacement mounting stand for split AC 1.5/2 TR capacity complete all as specified and as directed.
S & F in replacement PCB (Printed circuit board) suitable for Indoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and as directed.
S & F in replacement PCB (Printed circuit board) suitable for Outdoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and as directed.
S & F in replacement PCB (Printed circuit board) suitable for refrigerator any type any size complete all as specified and as directed.
S & F in replacement voltage stabilizer 4 KVA range 170 to 260 Volts, output voltage 230 volts AC supply 50 HZ having low and high voltage protection, intelligent time delay system, wall mounting type including mounting accessories time delay 180 seconds +/- 20 seconds as initial time delay complete all as per Volina or equivalent in AE / V - Guard complete all as specified and as directed.
Removing the window/ split type AC upto 1.5/ 2 Ton capacity of any make from any location for carrying out water servicing complete as and when ordered and installing back at original location, testing and commissioning complete all as specified and as directed. Note: -The rate of following deemed to be included in quoted rate: - (a) Cleaning the body, evaporator and condenser coil with detergent, combing the pins and flushing the water by using pressure pump. (b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower. (c) Wrapping suction and discharge pipe with foam insulation and white roll, changing drainage pipe when necessary. (d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, materials & labour, tools and plants, and back in on final position complete.
S & F PVC insulated multi stranded copper conductor 3 core 2.5 sq.mm, including connecting up and taking down existing unserviceable cable of any description and size complete all as specified and as directed.
M & L for shifting of Air Conditioner, window/Split type capacity up to 2 TR from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note: - The rate for following works deemed to be included in quoted rate: - (a) Transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls and as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoor units of split ACs with copper tubes, flairs nuts, warping suction and discharge lines with inculcating materials with necessary fixing arrangements such as bolts, nuts washers and clamps etc on walls (e) fixing PVC pipes 50mm dia for outlet of outdoor units to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as required at site with necessary junction boxes, PVC bends etc. including two length of PVC copper cables of 4 sqmm size for electrical connection of ACs.
S & F in replacement copper tube for Split ACs of size 1/4 inch complete all as specified and as directed.
S & F in replacement copper tube for Split ACs of size 1/2 inch complete all as specified and as directed.
Disconnecting electrically and opening of top cover and checking /rectification of minor problems like loose connection, replacement of terminal wires, compressor terminal lugs, fixing of nut bolts, rectification of electrical faults inside the split/window AC's including washing, cleaning of outer/inner unit complete all as specified and as directed.
S & F plugs top 5 Amp for electric connection of desert cooler etc complete all as specified and as directed.
S & F plugs top 15 Amp for electric connection for water coolers, deep freezers etc. complete all as specified and as directed.
M & L for rewinding of fan motor any make any size of desert cooler with super enamelled copper wire using with suitable gauge including materials such as insulating paper, varnishing, heating/baking and reassembling testing complete all as specified and as directed.
S & F in repair Fan motor/blower Fan Motor for Desert cooler any size complete all as specified and as directed.
S & F in repairs vertical/Horizontal pump for desert cooler with GI clamps suitable Upto 5 feet height discharge coolers etc complete all as specified and as directed.
S & F in repairs capacitor 4 MFD suitable for desert cooler of any cap & testing etc complete all as specified and as directed.
S & F suitable pad / grass ribs including packing complete set of three for each cooler complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_839087.xls
BOQ • 0.30 MB
RTD8565Coolingappliances.pdf
Tender Documents • 1.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .