Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹30.0 L+₹1.4 L (4.77%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹30.2 L+₹1.6 L (5.48%)Rejected-Finance | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹31.1 L+₹2.5 L (8.59%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L4 | Rejected-Finance Being higher bid value |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8974/E8
2021_MES_471730_1
GE/ALP (8974) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE ALIPORE KOLKATA
Class E and Category a (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹50,000
Yes
10 Jan 2022
31 Aug 2021
5 Oct 2021
31 Aug 2021
4 Oct 2021
20 Sept 2021
60 days
Amount
BSA/KOL/SR(BLDG)/02/2021-22 and BSA/KOL/SR(BLDG)/03/2021-22 Taking down roof trusses of any type above 4Mtrs and upto 8Mtrs, coupled rafters or trussed beams etc any position etc complete all as specified
Dismantling of timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section etc
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc complete all as specified
S&F Roof trusses (framed Fe 290 Gde 165), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S&F for Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall/ ridges etc, fixed with self tapping screws as specified.
Demolition of brick work built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed by the Engr-in-Charge.
Materials and labour for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) etc. complete all as specified and as directed by the Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified.
All as per item No 9 above but n.exc 1.5 sqm each.
S&F for second class hard wood (Sal), plain, solid straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed.
S&F for 30 mm thick facotry made flush shutters, solid core construction, with block board core and plywood face panels, commercial type both sides (ISI marked) all with 6 mm thick teak wood edging all round etc. complete all as specified and directed.
S&F for factory made 35 mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats etc. complete all as specified and directed.
S&F MS butt hinges medium weight, cold rolled of size 100 mm. etc complete all as specified
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S& F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
Supply and fixing Extruded aluminium alloy handles, 150mm long fabricated type., anodised complete all as specified and directed.
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified upto any story of bldg.
S&F for mild steel of grade Fe-290 in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, clamps, hold fasts and similar small articles.
S&F powder coated aluminium sliding window three track with two glass shutters using 5 mm thick float glass and one shutter with stainless steel wire gauge 0.36 mm dia 1.40 mm average aperture with necessary jointing cleats, glazing clips, rubber packing, powder coated min thickness 50 micron aluminium snap beading, screws etc complete all as specified and directed, using following frame sections:- a) Three track bottom - Section No. 20957 b) Three track top/vertical - Section No 20958 c) Handle - Section No. 20606 d) Inter locking - Section No. 20605 e) Top and bottom - Section No 20604 Make of aluminium section Jindal, Hindalco or equivalent and glass make Saint Gobian, Modiguard or equivalent.
S&F powder coated aluminium door shutters fixed including rolling machine with rubber gasket, stopper, cleats handles etc complete incl Aluminium door style of size 80mmx40mmx1.55mm and aluminium door frame 65mmx65mmx1.55mm section with 5mm thick sheet glass and necessary fittins etc. complete all as specified ( Minium thickness of owder coating 50micron)
Supply & Fix for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as directed.
S&F for Framed work such as grills to window/ventilation, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe - 290 Gde E-165
Taking down cement plaster of any discription on Brick/stone wall including racking out joints, hacking for key scrubbing down with water, remove Dust, debries/rubbish etc.
M&L for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick/concrete sufaces, plastered surface finished even and Smooth without using extra cement incl complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete sufaces as in ceiling etc, plastered surface finished even and Smooth without using extra cement incl complete all as specified and as directed.
M&L preparation of newly plaster surfaces and applying three coats white wash on walls complete all as specified and directed.
M&L preparation of new plastered surfaces and applying two coats of exterior acrylic emulsion painting over one coat of primer on walls complete all as specified and directed.
M&L preparation of old decorated plastered surfaces and applying two coats of exterior acrylic emulsion painting over one coat of primer on walls complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
M&L for preparation of old treated surfaces by complete removal of existing treatment, preparatory to distempering, priming plastered and other surfaces with chalk whiting and applying two coats of acerylic distemper on wall all as specificed and directed.
M&L preparation of old treated/decorated surfaces of ceilling by washing, rubbing down and stopping old distempered and painted surface and applying one coat of oil bound distemper etc all as specificed and directed.
M&L for preparation to new wall surface with chalk whiting and applying two coats of Aryclic distemper on wall complete all as specificed and directed.
S & F 3mm thick wall care putty on wall complete all as specified and as directed by Engineer-in-charge.
M&L for 4mm thick non asbestos cement false ceilling tiles of size 595 x 595 mm of approved design fixed with powder coated GI grid consisting of main Tee section of size (15mm x 30mm), cross Tee section of size (15mm x 23mm), and powder coating GI wall angle of size (20mm x 20mm) suitable for mounting tiles of 595 x595 mm with 2 mm dia GI wire suspended including fabrication complete as per manufacturers instructions fixed with steel rawl plug with nut and bolts arrengement with gred size 60 x 120 cm complete all as spd and directer by Enginer in charge.
M&L for Preparation of old painted surfaces of steel & iron of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engr-in-Charge.
S&F for helical wire spring of suitable ( Heavy duty ) size up to 35 cm fixed in repair by greasing etc complete and refixing covers in position for rolling shutter copmlete all spd and directed.
M&L for Grinding and polishing to previous polish kota stone complete all as specified and as directed by the Engr-in-Charge.
Material and labour in repair for Granite (of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms over and including 15mm screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade etc complete all as specified
M&L in repair for coloured Glazed ceramic tiles in vertical surfaces 450x300x7mm to 8mm thickness as per manufacture on vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm in cement mortar (1:3) backing of tiles complete all as specified and directed.
S&F in repairs Bib taps long body, fancy type and chromoum plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore and fixed fancy type and chromoum plated
S&F for Sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and waste pipe; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc. complete all as specified and directed.
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified.
S&F for 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles from site and rubbish off the premises all as per specified and as directed.
M & L for Machine cut kota stone slab flooring 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete Note : Screed bed shall be measured separately.
M&L for backing coat/Screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:4) as in floors complete all as specified and as directed by Engineer-in-charge.
M & L for Virified Ceramic tiles coloured for Flooring in rooms 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, over and including Screed bed or bedding layer of 15mm thick cement mortar (1:4) for laying floor finishesetc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-charge.
M & L for Chequered cement concrete tiles area not exceeding 0.16 Sqm and tile 22 to 25 thick set, jointed and pointed in neat cement slurry with greay cement and no pigments complete all as specified and directed. Note : Screed bed shall be measured separately.
M&L for 75mm thick PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in as in sub base complete all as specified and as directed.
M&L for backing coat/Screed bed or bedding layer of mortar 20mm thick in cement mortar (1:6) as in floors complete all as specified and as directed by Engineer-in-charge.
Material and labour for concealed point wiring for one light/fan/call bell point with single core 1.5 sqmm PVC insulated (FR-LSH) unsheathed multistranded copper conductor cable 1100 volts grade controlled by one No one way switch including single core 1.5 sqmm PVC (FR-LSH) insulated unsheathed multistranded copper conductor cable 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC nonmetalic rigid conduit medium grade with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator on 3mm thick hylum laminated/bakalite sheet cover after and including taking down of old existing point wiring including fixtures and fittings such as switch, ceiling rose, holders, socket, etc and making good the distrubed surfaces as per the existing complete all as specified and as directed by the Engr-in-Chage Note : Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing, Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No 54 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm copper cable complete all as specified and directed.
All as per item No 54 here-in-before but for 5 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm copper cable complete all as specified and directed.
All as per item No 54 here-in-before but for 5 pin 6/16 Amps switch socket combination on the independent board with single core 2.5 sqmm PVC insulated unsheathed copper cable 1100 volts grade and single core 2.5 sqmm copper cable as earth continuity conductor complete all as specified and directed.
Supply and fixing switch flush type 6 Amps 230 volts single pole one way complete all as specified and directed.
Supply and fixing socket outlet 5 pin, 6 Amps,230 volts flush type complete all as specified and directed.
Supply and fixing switch socket combination multi purpose 2 in 1, 5 pin, 6 Amp, 230 volts flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing 6/16 Amp switch socket combination multi purpose 2 in 1, 5 pin, 230 volts flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling rose surface bakelite three terminal 65 x 50mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing electronics fan regulator step type AC 240 volts 50 Hz complete all as specifiied and directed by Egnr-in-Chage.
Supply and fixing for AC power unit 6 module consisting of in built starter, plug top, isolator and box complete all as specified and direfcted by the Engr-in-Chage. Make : North West, Model ACPU 6 M-BT or equivalent approved make.
Taking down ceiling fan, dismantling blades and depositing the same to store for reuse and refixing the same after completion of false ceiling work including provision of cable from ceiling rose to fan complete all as specified and directed by Engr-in-Chage.
Taking down of exhaust fan, depositing the same to store for reuse and refixing the same after completion of false ceiling work including provision of cable from ceiling rose to fan complete all as specified and directed by the Engr-in-Chage.
Supply and fixing LED Tubelight fittings 4ft, 20 W, 220V, AC with extruded aluminum body, PC diffuser and inbuilt driver including connecting up with three core flexible copper wire of suitable size from ceiling rose to light fitting complete all as specified and directed by Engr-in-Charge. Make : CG Cat No. CCS-100-20-65-HL2-DP-NWH or equivalent in Phillips/Havells/Surya.
Supply and fixing as in repair MCB DB SPN 8 ways double door with 200 Amps rated bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces or wall complete all as specified and directed by the Engr-in-Charge.
All as per item No 68 here-in-above but for SPN DB 4 ways.
Supply and fixing in repair MCB 63 Amps, TPN, 240 volt "C" series, breaking capacity 10 KA complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repair MCB 06- 32 Amps, SPN, 240 volt "C" series, breaking capacity 10 KA complete all as specified and directed by the Engr-in-Charge.
Supply and fixing as in repair MCB 6 to 32 Amps, single pole, 240 volt "C" series, breaking capacity 10 KA complete all as specified and directed by the Engr-in-Charge.
Supply and fixing sub main wiring with two runs of 4 sqmm single core PVC insulated & unsheathed multi stranded copper conductor cable (FR-LSH), 1100 volts grade alongwith one run of 4 sqmm PVC insulated & unsheathed copper conductor cable (FR-LSH), 1100 volts grade, connected to common earth dolly as earth continuity conductor, deawn through PVC conduit after and including taking down old existing one and including necessary chase cutting and earth work for making good of disturbed surfaces complete all as specified and directed by the Engr-in-Chagre. Note : Three runs 4 sqmm cable and one run conduit shall measured as one length.
All as per item No 73 here-in-above but the sub main wiring with two run of 6 sqmm copper cable alongwith one run of 6 sqmm copper cable for earth continuity wire with PVC conduit. Note : Three runs 6 sqmm cable and one run conduit shall measured as one length.
Dismantling mild steel work of any description not otherwise provided for
Dismantling of plain or corrugated Asbestos cement (corrugated, semi-corrugated) sheets in roof covering incl ridges etc.
S&F for Steel work in MS tubes including special shaped washer, necessary FI angle iron if required to complete the works as in purlins, rafter etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 graded St-240 complete all as specified and directed.
S&F for steel ventilators with tope hung shutters including hinges with steel handle and steel peg stay,Glazing bar dovetailed or welded for receiving glass and including cutting holes in wall for fixing the ventilator and makding good the disturbed surfaces with the existing finishes to match complete all as specified and as directed by the Engr-in-Charge.
Demolition of cement concrete in ground floor and pavings n exc 15 cm thickness (below or above ground level complete all as specified and directed.
M&L for 75 mm thick PCC(1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor/pavings complete all as specified and directed.
M&L 25 mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in base of floor complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting,dado,and pillar over and including 10 mm thick plaster for backing coat in cement mortar (1:3) etc; laid and jointed with grey cement slurry and pointed with white cement mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for 75mm thick PCC (1:3:6) type C-2(Using 40 mm graded stone aggregate) as in plinth protection & hard standing complete all as specified & directed.
M&L for Machine pressed precast concrete coloured interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M 35 Grade complete all as specified and directed.
M&L for 50mm thick sand filling under interlock tile flooring complete all as specified & as directed.
M&L for Providing cement concrete type B-1, (1:2:4) (using 20 mm graded stone aggregate) as in benching concrete,coping ,hold fast etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete bldg all as specified and as directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distember over a coat of prime complete all as specified and directed.
M&L for prepartion of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer on wall surfaces complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed
M&L for preparation of old decorated surfaces by complete removal of existing treatment by brooming down or steel wire brushing scrapping down smoke soot and greasy spots and applying two coat of cement base paint on walls complete all as specified and directed.
S&F in repairs steel rolling shutters, without ball bearing, as specified including top cover anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete, push pull or manual type thickness of laths in 1 mm comlete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by the Engr-in-Charge.
TOTCO
PUTUL CONSTRUCTION CO.
NUPUR CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .