| 1 | L1₹44.6 LAccepted-AOC 112 AMBALA ROAD NARAINGARH AMBALA 134203 | NARAINGARH | AMBALA | HARYANA | 134203 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.3 L+₹72,486.50 (1.63%)Rejected-Finance 127 OLD NAGAR PALIKA BUNGLOW NO 60 NEEMUCH MP NEEMUCH MADHYA PRADESH 458441 INDIA | NEEMUCH | MADHYA PRADESH | 458441 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹46.5 L+₹2.0 L (4.43%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹48.7 L+₹4.1 L (9.27%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L4 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/S Davinder Kumar L3 | Chaudhary Constructions L4 | JINDAL ENTERPRISES L2 | J S CONSTRUCTION CO L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets as in roof covering complete all as specified and as directed. | 740 | Sqm | 20 ₹14,800 Lowest | 25 ₹18,500 | 25 ₹18,500 | 40 ₹29,600 |
| 2.00 | S&F Pre-painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50mm thick of any colour greeen/red having tensile strength not less than 550 Mpa as in covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. | 740 | Sqm | 900 ₹6,66,000 | 705 ₹5,21,700 | 725 ₹5,36,500 | 650 ₹4,81,000 Lowest |
| 3.00 | Demolition of brick wok built in cement mortor including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. | 13 | Cum | 100 ₹1,300 Lowest | 263 ₹3,419 | 1,000 ₹13,000 | 210 ₹2,730 |
| 4.00 | M&Lfor brick work with sub class 'B' old size bricks, class designation 7.5N, built in cement mortar 1:6 straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed. | 12 | Cum | 4,800 ₹57,600 | 5,252 ₹63,024 | 4,000 ₹48,000 | 3,800 ₹45,600 Lowest |
| 5.00 | M&L for brickwork with sub class 'B' bricks, of class designation 7.5N, straight or curved on plan to any radius, in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed. | 20 | Sqm | 1,300 ₹26,000 | 673 ₹13,460 | 1,500 ₹30,000 | 650 ₹13,000 Lowest |
| 6.00 | Demolition of cement concrete (un reinforced ) as in ground floors and pavings not exceeding 15cm thick (below or above ground level ) complete all as specified and as directed. | 15.2 | Cum | 150 ₹2,280 Lowest | 234 ₹3,556.8 | 900 ₹13,680 | 250 ₹3,800 |
| 7.00 | M&L for 40 mm thick cement concrete type B-0 1:2:4 using 12.5mm graded aggregate as in sub base of floor to receive floor finish, complete all as specified and as directed. | 380 | Sqm | 400 ₹1,52,000 | 234 ₹88,920 | 300 ₹1,14,000 | 120 ₹45,600 Lowest |
| 8.00 | M&L for glazed ceramic colured tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed. | 550 | Sqm | 850 ₹4,67,500 | 973 ₹5,35,150 | 880 ₹4,84,000 | 790 ₹4,34,500 Lowest |
| 9.00 | All as per srl item No 8.00 here in before but as in skirting laid over and including 10 mm thick backing coat of cement mortar (1:4), complete all as specified and as directed. | 60 | Sqm | 850 ₹51,000 | 993 ₹59,580 | 900 ₹54,000 | 790 ₹47,400 Lowest |
| 10.00 | Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each removing from store complete. | 28 | Each | 100 ₹2,800 | 93 ₹2,604 | 300 ₹8,400 | 70 ₹1,960 Lowest |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
7 Aug 2025, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
SPECIAL REPAIRS TO OTM ACCN (OP SHELTER-16 BLOCKS) AT SOUTH CAMP OF 274 TRANSIT CAMP UNDER AGE B/R-I AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2025_MES_719692_1
GE/TOKEN-34/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹97,000
Yes
27 Sept 2025
10 Jul 2025
9 Aug 2025
10 Jul 2025
7 Aug 2025
24 Jul 2025
Amount
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets as in roof covering complete all as specified and as directed.
S&F Pre-painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50mm thick of any colour greeen/red having tensile strength not less than 550 Mpa as in covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Demolition of brick wok built in cement mortor including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&Lfor brick work with sub class 'B' old size bricks, class designation 7.5N, built in cement mortar 1:6 straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed.
M&L for brickwork with sub class 'B' bricks, of class designation 7.5N, straight or curved on plan to any radius, in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
Demolition of cement concrete (un reinforced ) as in ground floors and pavings not exceeding 15cm thick (below or above ground level ) complete all as specified and as directed.
M&L for 40 mm thick cement concrete type B-0 1:2:4 using 12.5mm graded aggregate as in sub base of floor to receive floor finish, complete all as specified and as directed.
M&L for glazed ceramic colured tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and as directed.
All as per srl item No 8.00 here in before but as in skirting laid over and including 10 mm thick backing coat of cement mortar (1:4), complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each removing from store complete.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames)removing from store complete.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows & other frames/chowkhat of size 65 x125 mm comprising of vigin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ricehusk/wheat husk) and non toxicadditives (maximum toxicity index of 12 for 100 g,s) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position SS dash fasteners heavy duty of required dia and length complete all as specified and as directed. Note:- For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter, complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid colour prelaminated both side gauge door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant complete all as specified and as directed.
S&F factory made Aluminium window as per TD drg No. CEDZ/D-316 (for reference only) outer frame 40 mm x 114 mm with 1.3 mm thickness corner 45 degree vut and aluminium welded centre horizontal member size 40mm x 65mm also welded top hung shutter (01 No) size 40 mmx60mmx1.3mm thickness 45 degree cut mechanically joint with 6mm allen key bolt clamp, 12 mm SS 202 grade round bar at 100 mm c/c distance in handle 150mm c/c distace for safety grill welded at both ends with 6 mm SS 202 grade round bar 5 mm clear glass both side EPDM rubber gasket between (for openable shutter and fixed pan) hand lovar type single point lock, SS 75 mm long hinge & PVC magnet, full system powder coated with pure polyser coat of any shade as approved by GE and installing with silicon complete all as specified and as directed. Note - : For installation of window AC/desert cooler the provision of window glass shutter, grill and necessary fittings and locking arrangement for subject portion will be modified as per ground requirement during the execution as per direction of Engineer-in-Charge.
Dismantling boarding, any description, fixed in any position with nails/screws complete all as specified and as directed.
Supply and fixing of external wall system on Light Gauge Steel Frame work with outer face having 6 mm thick heavy duty fiber cement board fixed on 9 mm thick heavy duty fiber cement board confirming to IS 14862:2000, category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3 mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be counter sunk rib head of 1.60mm to 4mm thick of 8 to 10 gauge of length varying from 25 to 45 mm & internal face 12.5 mm thick gypsum plaster board fixed on 8mm thick fiber cement board conforming to IS 14862:2000 of category Ill type B (High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish complete all as specified and as directed. Note - : Cost of frame work to be paid for separately.
Supply and fixing internal wall panels on Light Gauge Steel Frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8 mm thick fiber cement board conforming to IS 14862:2000 of category Ill type B (High pressure steam cured) as per standard sizes fixed with self-drilling/taping screws/fasteners@60cm c/c of approved make, Screws shall be counter sunk rib head of 1.60mm to 4mm thick of 8 to 1 0 gauge of length varying from 25 to 45mm . Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish complete all as specified and as directed. Note - : Cost of frame work to be paid for separately.
M & L for filling the grooves (i.e.2-3 mm gap between boards) taping and jointing of the first layer 6mm and 9 mm thick cement boards with epoxy based sealing compound or with silicon sealant second layer is fixed over it in a staggered pattern complete all as specified and as directed.
M & L for fill the groove (i.e. 2-3 mm gap between boards}, taping and jointing 8 mm thick fiber cement board and 12.5 mm thick gypsum plaster boards with epoxy based sealing compound, acrylic based sealing compound, non woven reinforcement tape as per direction of Engineer in Charge. (Use a flexible knife so that no air bubble is entrapped. Allow 1-2 hours gap. Once hard tacky or set, apply a coat of acrylic based sealing compound paste to flash fill the beveled area. After 2-4 hours go on to repeat a skin coat with acrylic based sealing compound to securely embed the 40mm width non woven reinforcement tape. Use only flexible steel knife, such as provided with packs, to avoid air entrapment within compound. After overnight drying shrinkage apply a coat of acrylic based sealing compound to compensate shrinkage. Finally cover the bevel portion with any suitable overall skin complete all as specified and as directed.
Supply and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0. 75 mm thick steel sheet as per existing sections. The Steel sheet shall be galvanized (AZ-150 gms Aluminum Zinc Alloy coated steel having minimum yield strength 300-550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per 18:875-1987, ISO 800-1984 and 18:801-1975. The wind load shall be as per provisions of IS 875(part-lll). Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod , H-Brackets, Boxing Sections, L -Shaped Angles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11 mm lip in required length as per site requirement duly punched with dimple/slot at required locations as per existing section . The slots will be along center line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self-drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM 8633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 and 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self-expanding carbon steel anchor bolt of dia as per approved drawings and design subject to minimum 12 mm diameter and 121 mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100 mm in and located not more than 300mm from corners or termination of bottom tracks complete all as specified and as directed.
Supply and fixing false ceiling at sufficent heights with GRG (Glass Fibre With Semi With fully Reinforced Gypsum) false ceiling tiles 12 mm thick fully perforated micro tegular design of size 595 x 595 mm of approved texture and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter?locking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main?T runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and as directed.
M&L preparation of new wall/ceiling surfaces and applying water proof cement base putty of 1-1.5 mm thick to prepare the surfaces even and smooth and thereafter apply two or more coat acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer @ applied @ 2.20 Kg/10Sqm) complete all as specified as directed.
M&L for complete removal of old surfaces of wall and applying water proof cement base putty of 1-1.5 mm thick over plaster surfaces to prepare the surfaces even and thereafter apply two or more coat acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer @ applied @ 2.20 Kg/11Sqm) complete all as specified as directed.
M & L for refixing any type of boards/panels as in existing wall/ceiling or any ulternate location as directed. Note - Rate shall deemed to be included for cleats chennel etc.
M&L for preparation of old surfaces of wall and ceiling, applying two coat of oil bound distemper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wal/ceiling providing and applyingcement base putty of 1-1.5 mm thick over wall surfaces to prepare the surfaces even and smooth and finishing walls and thereafter applying two coat of oil bond distemper complete all as specified and as directed.
M&L for rendering 15 mm thick with ready mix plaster on stone masonary surface/ other than fair faces surfaces finished even and smooth without using extra cement including taking down existing cement plaster complete all as specified & as directed. Note: Rate for scaffolding arrangement to carry out the work upto 4 storey building deemed to be included in the quoted rate.
S&F stainless steel wire cloth.0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F 25 mm dia SS curtain rods (minimum 1.6 mm thick wall thickness AISI 304) fancy type, including SS bracket and SS finials decorative type complete for doors and windows as required complete all as specified and as directed.
S&F 100 mm size butt hinges stainless steel of AISI 304 complete all as specified and as directed.
S&F 300 mm long, stainless steel of AISI 304 grade, sliding door bolt with hasp, staple (bolt type) and fixing clipss of sheet, cast or extruded sections and fixing bolts and fixed etc complete all as specified and as directed.
S&F stainless steel of AISI 304 grade handle of size 200mm size long etc. complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for 75mm thick, cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even without using extra cement, complete all as specified and as directed.
M & L for forming construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and as directed.
Taking down carefully the old u/s Aluminium/ Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish all as specified and directed.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including new PVC conduit on surface medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required color with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified for following :- Note 01:- New conduit with connected accessories will be laid if there is damage in existing conduit and the rates are inclusive of quoted rates. Note 02:- the rate is inclusive of cutting/chasing and making good the disturbed surface with CM 1:3 and the same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete.
(a) One light /fan point controlled by one way switch
(b) One 3 pin socket outlet 5 amps independent board
(c) One 3 pin socket outlet 5 amps point on same board
(d) One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point.
S&F switch 6 Amps modular type,1M with red indication single pole one way, ISI marked complete all as specified and as direected.
S&F socket 6 Amps,2/3 pin combined modular type 2M ,shuttered type, ISI marked complete all as specified and as direected.
S&F switch 16 Amps, modular type 1M with red indication single pole one way, ISI marked complete all as specified and as direected.
S&F socket 6/16 Amps 2/3 pin combined modular type 2M,shuttered type , ISI marked complete all as specified and as direected.
S&F in replacement ceiling rose surface Bakelite 60x 25 mm two to three terminals, complete all as specified and as direected.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F of Building security light fitting 30 watt to be fitted at the pheripheral surfaces of the building including fixing with Ms clamp,nut,bolts complete all as specified and as directed.
Taking down of old unserviceable ceiling fan/exhaust fan any type / any size dismantling the blades and depositing safely to mes store yard complete all as specified and as directed.
Supply, Installation, testing and commissioning of 1200mm sweep BEE 5 star rated, Ceiling fan with Brush Less Direct Current (BLDC) Motor, Class of insulation : B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery not less than 220 CMM,not less than 365 RPM (tolerance as per IS:374-2019), THD less than 10%,including remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nuts bolts, washers, temperature rise =75 degree C (maximum), insulation resistance more than 2 mega Ohm, suitable for 230V, 50 Hz, single phase AC supply complete all as specified and as directed.
Supply & Fixing in replacement sheet metal enclousure for DB's where MCB's to be used Single pole and Neutral 4 way ,240 volts, double door bus bar neutral link,earth bar and din rail complete all as specified and as directed.
Supply & Fixing in replacement MCB SPN 63 Amps 'C' curve 240 volts.
Supply & Fixing in replacement MCB SP 6 to 32 Amps,'B' curve 240 volts.
M&L in replacement of earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed at site.
M & L for earth continuity conductor or main lead fixed to wall on batten or recessed or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/connecting as required 25X4 mm GI strip complete all as specified and as directed.
M & L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm x 2 core including taking out of old unsv XLPE cable of any type and size complete all as specified and as directed.
M & L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm x 3.5 core including taking out of old unsv XLPE cable of any type and size complete all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out for laying of cables complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cm each layers, complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Supply and laying GI tubing light graded 40 mm bore fixed to walls and ceiling or laid intrenches complete all as specified and as directed.
JINDAL ENTERPRISES (BID ID -3378797)
M/S Davinder Kumar (BID ID -3378803)
Chaudhary Constructions (BID ID -3378868)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .