| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹44.2 L+₹34,398.20 (0.78%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹45.5 L+₹1.6 L (3.63%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹47.2 L+₹3.3 L (7.51%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
3 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2024_MES_636406_1
86942/E8
Open Tender
Civil Works
Item Rate
180 days
DEOLALI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE DEOLALI
₹97,000
Yes
14 Mar 2024
8 Jan 2024
5 Feb 2024
8 Jan 2024
3 Feb 2024
22 Jan 2024
9 Jan 2024 - 16 Jan 2024
Amount
Demolition of brickwork of stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed.
All as per item No.02 above but except burnt bricks.
Taking down cement plaster any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for Rendering in 10 mm thick Ready Mix Plaster of Make- ACC’s “ACCOPLAST” / CK Birla’s “AEROCON” / Speed Dry Mix’s “ECO PLASTER” / “MAGIC PLAST” / “BUILDWELL on brick work or concrete surfaces of any description in wall/ceiling etc finished surfaces even and smooth with sogol finish complete all as specifed and directed.
M&L for Rendering in 12mm thick Ready Mix Plaster of Make- ACC’s “ACCOPLAST” / CK Birla’s “AEROCON” / Speed Dry Mix’s “ECO PLASTER” / “MAGIC PLAST” / “BUILDWELL on brick work or concrete surfaces etc finished surfaces even and smooth complete all as specifed and directed.
M&L for rendering 5mm thick plaster in cement mortar(1:3) on faces of brick work or concrete on surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for complete removal of existing treatment from wall upto plaster surface by electric sand paper grinder, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge.
M&L for applying two coat of exterior grade acrlic water proof white putty (1.50 mm to 2 mm thick) and applying one coat of exterior water based primer (after complete removal of old finish/newly plastered surface) by using airless spray techonology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressue and paint usage and certified by jpaint manufacturer and as mentioned in PS and accessories for applying exterior weather proof, should be able to spray in hard to reach areas and penetration of distemper, on the surface to achieve excllent application using limited manpower complete all as specified and directed. Note : - Sanding of old decorated surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.complete all as specified
M&L for preparation of old /new decorated/plasterd surface of wall applying two coat of interior grade white putty and applying one coat of primer (after complete removal of old finish/newly plastered surface) by using airless spray techonology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressue and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper, on the surface to achieve excllent application using limited manpower complete all as specified and directed. Note : - Sanding of old decorated surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.complete all as specified
M&L for preparation of surface of wall and applying two coat of exterior weather proof (on putty surface)100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 5 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Make: Asian (apex ultima), Berger (wather coat), nerolac (excel total)
M&L applying two coats of distemper oilemulsion,(on putty surface) using airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed.
Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and as as directed.
Dismantling hearth or wall tiling of any description, size and thickness including cement mortor bedding , removing rubbish off the premises etc complete all as directed.
M&L for Glazed ceramic tiles of size 600mm x 300mm x 7 to 8mm thick (coloured) of superior quality with highligter tiles fixed on vertical surfaces such as skirting/dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in cement mortar (1:4) and pointed in coloured cement to match complete all as specified and directed.
M&L for Double charged Vitrified tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors including screed bed 15mm thick in cement mortar 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L Virified tiles 8 to10mm mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors including screed bed 15mm thick in cement mortar 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L for non skid ceramic tiles of size 7 to 8mm thick (coloured) (Square/rectangular) area of each tile exc 0.06 but n exc 0.11 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement over 15mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L machine cut cudappah stone slab 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Z black Granite (of any type) 15-18mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including 15mm thick screed bed in CM (1:6), complete all as specified and as directed.
M&L for artificial Granite (of any type/colour approved by GE) 15mm thick in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. including 15mm thick screed bed in cement mortar (1:6), complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work.
M&L for RCC (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in chajjas.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surfaces of concrete
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No. 27 above but 6mm to 8mm dia.
M&L for cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in coping, bed blocks, filling of hold fast PCC or similar works including formwork complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n exc 1.5 sq. m each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq m each complete all as specified and directed.
S&F 1st class teak wood glazed & skeleton shutter 35mm thick factory made open rebated & prepared to receive glass gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass,gauge etc size of members of shutter as specified in SSR part-I , section 8, clause 8.24 (a) including melamet polishing complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples complete all as specified and directed.
S&F Aluminium wire netting nominal dia of wire 1.40mm and size of mesh 12mm and fixed with stainless steel wire stapples complete all as specified and directed.
M&L for preparation of New untreated steel or iron surfaces of any description, not otherwise, described, over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Factory made single extruded Prelaminated all sides of WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x100 mm single rebate comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made Make : ECHON/Sintex/Rajshree/Navaratan
Ditto but frame of size 65x 125 mm double rebate
S&F 30 mm thick Prelaminated both sides moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture both sides with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified
S & F powder coated aluminium sections for doors, windows, partition including fabrication of frame and shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, provn of AC opening and rubber beadings for fixing glass panes in frame complete all as specified by Engr-In- Charge. Note : (i) Glass panes/wire cloth will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading and glazing clips,hinges, handle. However it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate. Make : Hindalco/Indal (Indian Al Coy)/Jindal/Associated Profile & Aluminium Ltd/Ajit India
S&F for powder coated aluminium ventilator shutters with frame not less than 0.55 Kg/Rm, half bottom portion fixed with 4mm thick glass with fixed type shutter and top half portion lower type with 4mm thick glass and outer side fixed with stainless steel wire mesh, shutters aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary aluminium fittings etc complete all as specified and directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
Dismantling of boarding any description fixed in any position with nails complete all as specified and as directed
S&F factory made 100 % solid wood plastic composite Prelaminated single side (WPC) flush type shutter of 18mm thickness one side laminate consisting of panel of PVC profile of 18mm (+ 0.7mm) thick of denisity 600 kg per cum manufactured by ISO-9000 certified company using for shutter cillicia ply 18mm thick and fixed with frame. The thickness of shutter is edges painted by matching colour of PVC lining of plain/prelim coloured PVC sheet using etc complete as per manufacture specification.Make : ECHON/Sintex/Rajshree/Navratan
Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing
S&F auto Soft closing hinges 35 mm of 0 crank( KH-001) OR 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters Make :Hexa, Hettich, Hafele
S&F Ball bearing runners 45 mm Telescopic channel (KTS-20) full extension load capacity 50 kgs, Make :Hexa, Hettich, Hafele
S&F chrome plated stainless steel wire basket (storage basket) pull out type for large utensils, size 480 x 500 x 150 mm of Grade 304 with necessary fixing clips etc. complete in all respect as specified and as directed by engineer- in – charge.Make :Hettich, Hafele, Butterfly
S&F chrome plated stainless steel wire basket (cup and saucer basket) pull out type, size 380 x 500 x 100 mm Grade 304 with necessary fixing clips etc. complete in all respect as specified and as directed by engineer- in – charge.Make :Hettich, Hafele, Butterfly
S&F chrome plated stainless steel wire basket (plate basket) pull out type, size 380 x 500 x 100 mm Grade 304 with necessary fixing clips etc. complete in all respect as specified and as directed by engineer- in – charge.Make :Hettich, Hafele, Butterfly
S&F chrome plated stainless steel wire basket (cutlery basket) pull out type, size 380 x 500 x 100 mm Grade 304 with necessary fixing clips etc. complete in all respect as specified and as directed by engineer- in – charge.Make : Hettich, Hafele, Butterfly
S&F chrome plated stainless steel wire basket (Grain Trolley) pull out type, size 480 x 500 x 200 mm Grade 304 with necessary sliding frame structure, fixing clips etc. complete in all respect as specified and as directed by engineer- in - charge. Make : Hettich, Hafele, Butterfly
Supply chrome plated stainless steel wire basket (Bottle pull out) pull out type two self, size 120 x 500 x 432 mm with necessary sliding frame structure, fixing clips etc. complete in all respect as specified and as directed by engineer- in – charge.” Make : Hettich, Hafele, Butterfly
S&F width of flaps (When open) in 40 mm continuous (piano) hinges, mild steel, bright finish or electrogalvanised.
S&F Hasp and staple, safety type,brass with mild steel hinge pin including bolt to hinge plate and fixed with screws 125mm size.
S&F for door/shutter catcher, magnetic stopper/holder with striking plate for WPC board cabinets, cupboard shutters complete all as specified.
S&F for brass knobs 35-40mm dia complete all as specified.
S&F 100 mm long Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, typeB-11 complete all as specified and as directed.
S&F brass floor door stoppers double legged length 140mm with hard drawn steel spring fitted in floor complete all as specified and as directed.
S&F 150 mm long Extruded brass handles designer type, fabricated type polished complete all as specified and as directed.
S&F 150mm size Brass barrel tower bolts, with cast or sheet barrel and rolled orcast bolts and fixed complete all as specified and as directed.
M&L for 250mm long Brass, sliding door bolt withsand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed.
S&F in repair 25 mm stainless steel curtain rod complete all as specified and directed by Engr-in-charge.
S&F SS heavy duty decorative brackets suitable for 25mm dia curtain rod (minimum projection from wall 75mm) fixed in wall including drilling, rawl plug, screws etc complete all as specified and directed. Note: Curtain rod shall be measured and paid separately
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 510mm x 510mm bowl size 460x460x230mm, complete all as specified and directed.
S&F vitreous china single piece WC of Size: 380x700x665 mm, Single Piece WC with PP Soft Seat cover, Hinges, Fixing Accessories, Accessories Set, and Cistern fittings, P trap-180mm complete all as specified and directed Make Jaquar cat part No CNS-WHT-851P180SPP or equivalent in kohlar, grohe and Roca
S&F in repairs glazed earthen ware viterous china wash down water closet(pedestal pattern) white coloured with and including plastic water closed seat, white, closed pattern with recessed bottom, and cover and mild steel chromium plated hinging device etc complete all as directed. Make somany Cat Part No. SMART EWC P or Equivelent in Cera/Hindware/Parryware
S&F in repair vitreous china Wash Basin counter Top 600x400x185mm including stainless steel bottle trap and 40 mm dia GI pipe up to Floor trap complete all as specified and directed by Engr-in-Charge Make : Cat Part No SLS-WHT-6601 & ALD-769L250x190 of Jaquar or equivalent in kohlar, grohe and Roca
S&F decorative type WHB Vanity with wash basin and mirror and cabinet floor mounted made out of coloured PVC board of size 900x600/900 complete all specified and approved by GE Make: Cat part No. TRIUMPH of Somany or Equivalent in Hindware /Parryware /Cera
S&F in repairs glazed earthen ware viterous china wash basin white coloured (flat back or angle back type), size 550x400 mm and including CI brackets, outlet of 32 mm bore HDPE outlet pipe with necessary fittings ,32 mm bore brass CP waste couplings and bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed etc complete all as directed.
S & F in repair 15 mm bore, fancy type, bib taps, long body, cast copper alloy, 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge. Make : Cat Part No FLR- 5047 N of Jaquar or equivalent in kohlar, grohe and Roca
S & F in repair 15 mm bore, fancy type, angular valve, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed by Engr-in-Charge. Make : Cat Part No FLR-5053 N of Jaquar or equivalent in kohlar, grohe and Roca
S&F for 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends as fixed in repairs complete all as specified and as directed..
S&F in repair Health Faucet (ABS Body) with 1.20 M Long PVC Tube and wall Hook screwed down to GI pipe or union/angle valve complete all as specified and directed by Engr-in-charge Make Jaquar Code No- ALD-CHR-583 or equivalent in kohlar, grohe and Roca
S & F in repair CP, soap dish complete all as specified and as directed by Engr-in-Charge. Make Jaquar Code No- AKP -35731 P or equivalent in kohlar, grohe and Roca
S&F in repair Maze Overhead Shower 200X200mm Square Shape Single Flow (Body & Face Plate Stainless Steel with Chrome Finish) with Rubit Cleaning System including showe arm of size 400x25x25mm sq shape for wall mounted showers with flange, fixing to steel pipe or union complete all as specified Make Jaguar (Cat part No : OHS-1619 & SHA 455L400 or equivalent in kohlar, grohe and Roca
S&F sheet glass corner shelf wall mounted shelf assembly consisting of 5mm thick sheet glass 220mmX220mm size with chromium plated bracket guard and railing 50mm high complete all as specified and as directed. Cat Part no CAN -1173 of jaquar or equivenet in Kohlar, grohe and Roca
S&F in repair Towel Rack with Lower Hanger (Stainless Steel) with hook complete all as specified and directed Make Jaguar (Cat Part No: AHS-1581H) or equivalent in kohlar, grohe and Roca
S&F in repair brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges.
S & F in repair for 15 mm bore, fancy type, Wall Mixer 3-in-1 System with Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange and including Telephone Shower complete all as specified and as directed by Engr-in-Charge Make Jaguar Cat Part No: FLR-5281N, Hand shower HSH 1715, flexible tube SHA-549D12 or equivalent in kohlar, grohe and Roca
S&F in repair 15mm dia brass chromium plated Single Lever Sink Mixer With Swinging Spout on Upper Side (Wall Mounted Model) With Connecting Legs & Wall Flanges for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. Make Jaguar Cat Part No: FLR-5165 or equivalent in kohlar, grohe and Roca
S&F in repair 15mm dia brass chromium plated Central Hole Basin Mixer single lever tall boy with 150mm extension body fixed spout without popup waste system with 600mm long braided hoses for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. Make Jaguar Cat Part No: FLR-5005NB or equivalent in kohlar, grohe and Roca
S&F in repair 15mm dia brass chromium plated two way bib cock with long flange screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. Make Jaguar Cat Part No: ARI 39041 or equivalent in kohlar, grohe and Roca
S & F in repairs PVC valve less, syphonic action type, flushing cistern 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle, including brackets etc complete all as directed.
S&F in repairs 15mm size fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as directed. Make Jaguar Cat Part No: LYR-CHR-38021 or equivalent in kohlar, grohe and Roca
Dismantling of water tanks (RCC Tank/PVC Tank) including disconnecting all connections etc Any capacity. complete all a specified
S&F rotational moulded polythylene water storage tank 1000 ltrs capacity (cylindrical/ vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing ball brass valve high pressure with polythene float and fly nut, 25mm bore complete for following capacity of tanks
S&F rotational moulded polythylene water storage tank 500 ltrs capacity (cylindrical/ vertical with closte top) hoisted and fixed in position all as specified in SSR Part-I including providing and fixing ball brass valve high pressure with polythene float and fly nut, 20mm bore complete for following capacity of tanks
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed.
Supplying and laying of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S&F 25 mm boreTubes, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Cutting chases in Stone, concrete block or slab walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth all as specified and as directed.
S&F in repair 25mm bore Gun metal gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed.
S&F in repair 20mm bore Gun metal, globe or gate valves with iron wheel head screwd both ends for iron pipes complete all as specified and directed.
Dismantling of PVC Pipes with fittings upto 75mm to 110mm dia complete all as specified and as directed.
S&F for 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed.
S&F for 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall complete all as specified and as directed.
S&F PVC (SWR) bend with access door any radius 110mm complete all as specified and directed.
S&F PVC (SWR) bend with access door any radius 75mm complete all as specified and directed.
S&F for 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
S&F 75 mm PVC (SWR) junction single T equal or unequal complete all as specified and directed .
S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for special treatment to floor/wall sunken portion with demolition of PCC with plaster of entire sunken area (bottom & sides upto dado level) including removal of demolished material exc 250m and n exc 500m, prepration of surface by cleaning to remove loose particles, dust, latance etc, replacement of floor trap, and applying 10mm thick plaster in CM (1:4) with WPC liquid Conplast 421,and applying one coat each of Nitoproof 100 priming coat @1Ltr/5Sqm, after the priming coat applying Nitoproof 120 on plastered surfaces @1Ltr/2.5Sqm, filling the sunken floor with PCC (1:5:10) using brick bat and WPC Conplast - 421, rendering again 40mm thick in CM (1:4) mixed with WPC Conplast - 421, area of floor/kitchen upto 0.5 Sqm complete all as specified and as directed.
Material and labour for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed:- (a) Demolition of Cement concrete/brick bats filled on sunken slab upto mother slab including removing and Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc. (b) Brushing cement slurry with 1.2 kg of cement per square metre duly blended with & including water proofing compound. (c) 15 mm thick (Average thickness) plaster in cement mortar (1:4) mixed with water proofing compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding. (d) Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gm/Sqm) (e) M&L for PCC 1:7:12 type F2 using brick course agreegates for filling of sunken portion after conceling all menbrane upto FFL and sealing all joints to the entire satisfaction of Engineer-in-Charge. (Note:- Floor area shall be considered for measurement & payment purpose)
Material and labour for water proofing treatment to sunken slab, walls, etc, and shall be carried out as specified below and as directed:- (a) Demolition of Cement concrete/brick bats filled on sunken slab upto mother slab including removing and Clean the sunken portion of toilet / Baths/ WCs/ Kitchen thoroughly to remove laitance, dirt, dust etc. (b) Brushing cement slurry with 1.2 kg of cement per square metre duly blended with & including water proofing compound. (c) 15 mm thick (Average thickness) plaster in cement mortar (1:4) mixed with water proofing compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe and curing the sunken portion with water minimum for 48 Hrs by ponding. (d) Applying self adhesive type APP based polymeric membrane minimum weighing not less than 3.6 kg/ Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gm/Sqm)
S&F LDPE pipe 40mm bore fixed to wall/ceiling with bends/elbow complete all as specified.
S&F in repair mild steel ordinary rat tail rod pattern spring 300mm size including roller & roller plate and incl welding complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in concrete bed to 150mm bore drain pipes including packing under & haunching against the sides of pipes after they are laid & tested for 150mm bore pipe including demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement concrete mortar complete all as specified and as directed.
M&L for Reinforced concrete pipes 150mm bore class NP-2, laid and jointed complete with collars, complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B-1 using (20mm aggreates) set in CM (1:4) as in cover slabs (for manhole etc) & simillar articles with plain faces complete (Reinforcement will be measured and paid separatly) all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out hard/dense soil.
Returning, filling in including spreading, levelling, watering & well ramming in layers n.exc 25cm.
M&L for Providing, cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing complete all as specified and as directed .
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 5mm thick mirrors with fixed with stainless steel bolt & nut and fixed to brick/stone masonry walls built in cement mortor etc complete all as directed.
M&L in repair water proofing treatment on roof slab including picking, sweeping clean and washing down with water to remove dust & providing water proofing treatment described as under:- (a) Surface preparation with Asian smart care mortar and GP grout mortar and treating of construction joints, bore packing, filling of honey combs with polymer modified mortar (Cement ; Sand : smart care multipurpose polymer of Asian Paints or equivalent product of BASF/Fosroc) (b) Cleaning the surface and applying (Resin & Hardner) smart care Epoxy Primer 2k of Make Asian paints or equivalent product of BASF/Fosroc) on the cleaned surface for bonding of PU magnum with the existing concrete surface. c) Supplying, providing and applying water proofing treatment to Terrace area with Asian Paints Smart care PU magnum, single component highly elastomeric seamless cold applied Pure PU coating or equivalent product of BASF/Fosroc) including all necessary surface preparation, coving using smart care multi purpose polymer, water pond test, etc. complete as per manufacturer's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of min 1mm. The coating shall have dual combination of min 250% elongation and >2.5mpa tensile strength. Execution to be done with authorised applicator of the manufacturer using airless spray technology with 7.5HP power and max working pressure of 6750 PSI and company back guarantee to be given by the contractor. Work will be executed in smart assurance system complete all as specified and directed.
M&L for green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed by Engineer-in-charge.
S&F in repairs stainless steel plate rack of size not less than 90cmx75cm fixed with stainless steel screw including taking out old unserviceable wooden plate rack as approved by GE complete all as specified.
Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
Taking down unserviceable sub mains wiring including earth continuity any type / size with surface casing / caping / TW batten / PVC conduit surface or recess and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
Dismantling and taking down unserviceable main switches, DB etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
Material and labour for point wiring with two runs of stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-
One light point controlled by one switch.
One fan point controlled by one switch
One 3 pin socket outlet 5 Amps on the same board.
One 3 pin socket outlet. 5 Amps on the independent. board
126 One bell point controlled by one switch
All as per item no 125 above but One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire.
All as per item No 126 above but One 15 A socket outlet on the same board
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specifed .
Supply and fix Bell push button 5 Amp, flush type complete all as specified .
Supply and fix Bell, Ding Dong electric AC 230 Volts single pole complete all as specified and as directed.
M & L for switch socket combination 3 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
M & L for switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and as directed.
S&F steped type electronic fan regulator flush type (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep 100 watts
S & F in replacement of lamp angle/batten holder Bakelite Pin/Retrofit type with 10 watt LED Lamp (B22) all as specified and as directed.
S&F surface/wall mounted LED Light fittings, regal Batten Double side for LED Tube suitable for T8 LED 4 feet long lamp, with 18 W LED, with suitable driver complete all as specified and as directed. Make: Havells (Cat No: REGALBATTENT 5UPTO1X18WDSBSWH + CRYSTAL 1213T8DSTL18WLED865SGLASS) or equivalent in Crompton Greaves / Bajaj
S&F wall mounted LED Light fittings, 2 feet long, with 9 W LED and suitable driver complete all as specified and as directed. Make: Havells (Cat No: LUMILINEBS9WLED865SPCWH) ) or equivalent in Crompton Greaves / Bajaj
Taking down light fittings any type and S&F Decorative wall light fixture with made up of Polycarbonate, B22 base with 10 Watt LED lamp all as specified and as directed . Make: Havells city-2 LHDL03160099) or equivalent in Crompton Greaves / Bajaj
S&F LED Light fitting 1x9W Bulkhead luminaires including LED light driver connecting up with three core flexible copper conductor cable of suitable size
Supply & Install in replacement of building security light 30W LED energy saving Luminaire With high Power LED as light Source, Symmetric type including required size of GI bracket ,accessories, clamps and eletric connections complete all as specified and as directed. Make : Havells (Cat No ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Crompton Greaves / Bajaj
S&F Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 20 Amps MCB SP complete as specified and directed Make : L&T (Cat No: DBMPPS332SD) or equivalent in Legrand / C&S / Havells
S&F Sheet Metal enclosure for TPN DBs, 4 Ways, Double Door(IP-43), built- in bus bars complete suitable for 240 Volts, AC, 50 Hz complete all as specified and as directed Make: L&T / Legrand /C&S/Havells
S&F Sheet Metal enclosure for SPN DBs, 12 Ways, Double Door(IP-43), built- in bus bars complete suitable for 240 Volts, AC, 50 Hz complete all as specified and as directed Make: L&T / Legrand /C&S/Havells
S&F MCBs, TPN, 440 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
S&F MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
M&L submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 10 Sqmm (nominal area) each and one single core 10 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate.
All as per item No - 146 above but with 2 runs of 4 Sqmm cable with one run of 4 Sqmm cable for earthing.
Taking down celig fan and painting of celing fan comlete in situ with synthtic enamel paint by spraying includin filling cavities with filler one coat after cleaning all dust and refixing/ hanging the same all as specified
Taking down exhaust fan of size 230mm and painting of exhaust fan comlete in situ with synthtic enamel paint by spraying includin filling cavities with filler one coat after cleaning all dust and refixing/ hanging the same all as specified
Supply and Fixing/Install New Exhaust Fans PVC body 200 MM Sweep with accessories and eletric connection including taling down old exhaust fan and depositing E/M store yard complete all as specified and as directed. Make:-Havells Ventil Air DX / DX-HS White
Taking down electric storage water heater (geyser) from existing position and keep in safe custody in sore, refixing the same in working condition on existing wall including electric connection and fixing arrangements all as specified
Taking down unserviceable energy meter and depositing to E/M store and suply and fix multi feature with LCD display tamper proof electronic meters with optical Port+Box suitable for A/C single phase, 2 wire, 240 volts system with optical Port, cass 1.0 accuracy as per IS: 13779 & CB IP 88 specification of capacity 10-60 Ams (basic to 60 Amps (maximum) with BOX having under mentioned features including necessary incoming & outgoing connection with existing cable complete all as specified and as directed. Make : L&T or Equivaent
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and testing on completion.
Supply and lay cable XLPE insulated Heavy duty screanedPVC bedded, galvanized steelstrip or wire armoured, electric power cable 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in soft/ loose soil complete all as specified.
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified.
Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick.
M & L for Boring of holes under road, pavement, hard standing by trenchless technology for laying of GI Pipe for LT cable by using necessary machinery including laying of Heavy duty GI pipe of 80 mm dia all as specified and as directed by Engr-in-Charge
S & F Steel pipe glavanized light grade of 40 mm core laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth strip including clams with bolts nuts and wasers complete ass as specifed.
Alpha Construction
M/S SAMEER SUBHASH PATANI
sunway associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .