| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.2 L+₹59,127.75 (2.61%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.5 L+₹87,796 (3.88%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹24.1 L+₹1.5 L (6.44%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹25.3 L+₹2.7 L (11.8%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
4 Feb 2021, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
SPECIAL REPAIR TO BLDG NO. P-04 AND P-165/01 UNDER ZONE-I AREA AT JAIPUR MIL STN
2021_MES_411720_1
GE/J-59/2020-21
Open Tender
Civil Works
Item Rate
180 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹58,000
Yes
2 Mar 2021
12 Jan 2021
6 Feb 2021
12 Jan 2021
4 Feb 2021
23 Jan 2021
12 Jan 2021 - 22 Jan 2021
Amount
Taking down cement plaster or cement lime plaster/ tiles of any descrption on PCC/ stone surface/ brick surfaces of wall or ceiling including raking outs joints, hacking for key scrubbing down with water etc
M & L Rendering 15 mm thick on stone masonry wall surfaces in CM 1:6 finished even and smooth without using extra cement
M & L rendering 15mm thick on stone masonary surfaces or surface other than fair faces of brick work on wall in CM 1:4 finished even and smooth without using extra cement.
M & L Rendering 10 mm thick on ceiling in CM 1:4 finished even and smooth without using extra cement
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distermper over a coat of birla putty
M & L preparing new plastered surfaces and applying three coats of oil bound distemper on ceiling over a coat of birla wall care putty
M & L preparing new plastered surfaces and applying two coats of cement base paint on wall
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) , removing serviceable tiles to store and rubbish off the premises
M&L 25mm thick plain cement concrete type B-0, 1:2:4 ( 12.5mm graded stone aggregate) as in floor
S&F coloured glazed ceramic tiles size 300 x 450mm x7mm thick edge cut/ joint free on walls etc in the combinatin of light and dark shade concept set & jointed in neat cement slurry & pointed in white/ coloured cement to match over 15mm thick plaster in cement mortar (1:4)
Non skid cermic coloured tiles 7 to 8mm thick joint free (square/ rect) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15mm thick screed bed in CM 1:6
Non skid cermic coloured tiles 7 to 8mm thick joint free (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 15mm thick screed bed in CM 1:6
S&F light shade vetrified ceramic tiles edge cut 10mm thick ( square/ rectangular ) polished, area of each tiles not exceeding 0.36sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 15mm thick screed bed in CM (1:4) finished fair and even
All as per item No 13 above but as in skirting/ vertical surface over & including 10mm thick rendering on stone masonary surface or surface other than fair faces of brick work in CM 1:4
S&F for two way bib cock with wall flange and aerator complete all as specified and directed by Engr-in-Charge
S&F in repair PVC connection 15mm dia 60cm long with 2 Nos brass check nuts with washer complete all as specified
M&L CP fancy type centre hole basin mixer 15mm bore cast copper alloy with 450mm copper hose/ braided hose without popup waste system quarter turn complete all as directed
M&L of 15mm brass CP mixer hot & cold water screwed down for iron pipe and fixed
M&L towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats ( minimum weight 170 gms)
S&F brass chromium plated shower rose 65mm size with swivel joint type including fixing to steel pipe of 15mm bore or union includng taking down of old shower rose of any size ad type
S & F as in repair stop valves cast copper alloy, fancy type chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 15 mm bore fixed .
S&F 15mm bore chromium plated bib taps (fancy type) long body cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes all as specified
Demolition of old existing unserviceable WHB glazed and S&F vitreous china wash hand basin white of size 550 x 400mm flat back excluding taps, waste china and plug but including brackets including cutting for and pinning in ends of brackets or erecting stand complete in repair
Demolition of old existing unsv EWC seat and S&F vitreous china wash down water closet pan ( pedestal pattern) white including connections to drain ( or outgoing pipe) and to flushing pipe anti sypohonage pipe etc & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinges device complete
S & F in repair PVC valveless, syphonic action type flushing cistern 10 liters capacity, low level, white with inlet, ball valve, float and handle incl brackets and flush pipe of polyethylene of low or high density or PVC, 32mm dia suitable for low level cistern,
S&F in repair waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts flange end bedded in red leads cement and other end fixed.
S&F in repair bottle trap with internal partition 32mm of PTMT having minimum water seal of 25mm (minium weight of 32mm - 260 gms/ 40mm -270 gms fixed.
S&F in repair stop valve 15mm copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions
S&F in repairs stop valves 20mm bore copper alloy screwed down high pressure with crutch of butter fly handle screwed both ends for iron pipe or for union
M&L of healthy faucet ABS body with 2 mtr SS braided connection pipe.
Dismantling of old unserviceable trap and S&F of PVC Nahani / floor trap and square in size of 100 x 100mm including MS chromium plated grating 125mm dia of weight not less than 50gm for floor trap/ Nahani trap
Dismantling and taking up or down the existing unserviceable GI pipe and S&F new galvanised steel water tubing medium grade with all fittings and fixed complete to walls and celing or laid in floors of following :- (a) 15 mm bore
(b) 20 mm bore
S & F in repair 500 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe pipe etc complete all as specified in SSR Part I complete all as required.
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed bore dia of pipe 20mm
M&L for providing circular, raised platform of height 20cm below the tank and base 15cm more than the external dia of tank of PVC cylindircal water tank of capacity 500 / 1000 litre using PCC 1:3:6 type C-1 using 20mm graded stone aggregate with smooth finish complete all as directed.
S&F in repairs vitreous china water closet Indian type 580mm long pan white with 'P' or 'S' trap front or ack inlet footrest including provn of lime concrete bedding including connections to flushing cistern/ pipe and making good distrubed portion to match
S&F in repair box type mirror PVC cabinet of size 475 x 600 x 150mm all as specified
S&F soap dish vitreous china white approximate size 160 x 160 x 90mm fixed to plugs with chromium plated (CP) brass screws
S&F in repair toilet paper holder for CP fixed to walls with chromium plated (CP) brass screws fixed.
S&F UPVC (SWR) pipe single socketed, any in length with rubber ring joints laid in trenches or in floors type 'B' ISI marked of 75mm bore
S&F UPVC (SWR) pipe single socketed, any in length with rubber ring joints laid in trenches or in floors type 'B' ISI marked of 110mm bore
S&F UPVC (SWR) bends of any radius 75mm bore
S&F UPVC (SWR) bends of any radius 110mm bore
S&F UPVC (SWR) junction single (single T) equal or unequal 75mm
S&F UPVC (SWR) junction single (single T) equal or unequal 110mm
S&F UPVC (SWR) vent cowl 110mm
S&F PVC (SWR) floor trap 75mm dia plain with grating including joining with solvent cement
M&L PVC (SWR) gully trap 125/110mm setting & jointing with solvent cement
S&F Corner glass shelf (large) of size 300x300mm complete all as specified and directed by Engr-in-Charge.
M&L in repair fancy type SS brackets for curtain rod fixed complete all as directed.
M&L of 20mm dia drapery fancy type curtain rod fixed in repair
M&L for fancy type caps/ side bulbs PVC powder coated suitable for curtain rod fixed in repair
S&F factory made solid PVC moulded door shutter with particle board core 28 to 30mm thick (stiles) with 2, 4 or raised panel design with2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face supplying & fixing in frame at site as per specification & drawing including PVC sheet fixed on flush shutter in lipping in case of PVC sheet is heat bent as lipping on the edges of doors
S&F solid PVC frame ( single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth out integral skin with suitable metal stiffner and fxed with 100 x 8 sheet metal CSK screws complete all as specified and shown on drawing (Note := Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S & F framed work as in doors or gates of angle or other section as chowkhat or shutters, tie bar, hold fast, guard bars, brackets etc and fixing complete Fe 290 (Gde-E-165)
S&F MS holdfast, hook and pintle hinges, large hasp and staples, clamp, hooks for hanging fans and similar small articles conforming to Fe- 290 Gde E- 165 including necessary welding etc and fixed in position
Cutting holes in stone/ brick walls built in CM for inserting hold fast & making good dismantled portion in CM (1:3) depth of embaded portion of hold fast n. exc half brick
S & F 35mm thick factory made plain, framed, paneled door shutters kiln seasoned and chemically pressure treated second class, hardwood (two panels) with lock rail and panel of 9mm thick BWP commercial marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive confirming to IS-710. The size of rails and style shall be as per IS-1003.
S & F 35mm thick factory made second class hardwood glazed and skelton door shutter kiln seasoned and chemically treated, open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc complete. The size of members of shutters shall be as specified in MES SSR Part-I complete all as directed.
S & F butt hinges of size 100mm medium weight cold rolled mild steel and fixed
S&F aluminium anodised barrel tower bolts 150mm long of extruded section
S&F aluminium alloy anodised sliding door bolts 300mm long with hasp and staple ( bolt type) & fixing clips of sheet or extruded section & fixing bolts & sliding bolts of extruded section
S&F aluminium anodised handle 125mm size
S&F aluminium anodised floor door stopper overall length 140mm double legged with rubber shoe fixed to bottom rails of door
S&F MS spring hinges 300mm ordinary rat tail rod pattern including roller and roller plate complete fixed to wooden/ angle iron chowkhats
S&F galvanised mil steel wire cloth 0.50mm nominal dia of wire and average width of aperature 1.00 mm and fixed with tinned tacks or galvanised wire staples all as specified
S&F in repair galvanised mild steel wire cloth 0.50mm nominall dia of wire and average width of aperature 1.00 mm and fixed with tinned tracks or galvanised wire staples all as directed.
M & L Preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
M & L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed
Demolition of stone slabs in roofs, suspended floors, chajja, landing etc any thickness jointed in any mortar
M&L granite 16 to 18mm thick ( of any type) work ( table rubbed and polished in steps, jambs, pillars, windows cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L for sand stone slab 7.5mm thick in chajjas, sunshades, shelves, landing, cover stones, templates etc not exc 2m in length, punched dressed on face and along exposed edges, self faced on the other side and set and pointed in cement mortar 1:2 complete
M&L marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, treads, window cills, cooking platforms and like in cement mortar (1:4) inclcuding pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade makrana doogri
Cutting holes into or through cement concrete slabs, chajjas etc reinforced or otherwise ssuperficial area not exc 100 sqcm
S&F sink with drainage board made of stainless steel 1.0mm thick for kitchen with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or with 7 including fixing cantilever brackets and connecting union to pipe, overall size 1120mm x 457mm bowl size 460 x 330 x 203mm includng waste pipe of polythelene of flow or high density or PVC 32mm dia & waste fitting brass chromium plated for 32mm bore with long screwed shanks and fly nuts including making holes in stone walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0 complete including taking down of existing old sink.
S & F in repair stainless steel kitchen plate rack of overall minimum size 900 x 750 x 225mm with partitions for small/ large plates etc made out of stainless steel 24 gauge, fixed with rawl plug and CP steel screws all as directed of approved quality
Taking down chowkats or frames with shutters exc 1.50 sqm but n exc 4.00 sqm each (without taking off shutters from the frames).
Taking down chowkats or frames with shutters not exc 1.50 sqm each (without taking off shutters from the frames).
Taking down shutters of any description exc 1 sq.m and n not exc 2.00 each
Aluminium powder coated frame for holding of two/three/four track sliding shutters fixed type with aluminium section weighing 0.55 Kg/mtr incl necessary joining, cleats glazing clips, rubber packing powder coated aluminium snap beading, screws etc and beading for fixing of galvanised wire mess complete all as specified
Aluminium powder coated frame for fixed type with aluminium section weighing 0.55 Kg/mtr incl necessary joining, cleats glazing clips, rubber packing powder coated aluminium snap beading, screws etc and beading for fixing of galvanised wire mess complete all as specified
Aluminium powder coated door/ window shutter openable/ sliding type, partion wall with al section weighing 0.55 Kg/mtr incl necessary joining cleat, glazing clips, rubber packing aluminuim powder coated snap beading, screws, handle & tower bolt etc complete all as specified
Hacking out old broken glass any thickness size, quality or description from wooden/ steel frames fixed with beads/ metal pinning , S&F 3mm thick sgeet glass in square not exc 0.50 Sqm in each pane fixed with wooden beads or putty ( in metal frames etc) complete all as specified
S & F 4 mm thick plain sheet glass ordinary quality and glazing with oil putty in sqaures not exc 0.5 sqm in each pane.
S & F 3 mm thick figured glass pin head type and glazing with oil putty in sqaures not exc 0.5 sqm in each pane.
M&L particle board 19mm medium density flat pressed single layer type or three layer with BWR type adhesive fixed with screws to timber frame work
M&L of kitchen basket stainless steel size 435mm x 510mm including stainless stee; guide channel
S&F Auto close hinges, stainless steel, bright finish or electrogalvanised.
S&F brass handle of 100mm size type polished bright
S & F framed work as in grills, gratings etc with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways etc and fixing complete Fe 290 (Gde-E-165)
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 for raising of height of drain, manhole / wall complete all as specified.
M&L chequered cement concrete tiles 20cm x 20cm x 20mm thick , set , jointed and pointed in neat cement slurry in floors with grey cement and pigment over 20mm thick screed bed in CM 1:6
M & L for 25 mm thick sand cushion layer complete all as specified and directed
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement all as specified and directed
All as per item 98 above but except tiles
M&L scrapping roof surface with wire brushes and washing with water etc including taking down old cement plaster, PCC of any thickness, description in any situation ,position and roof treatment any type for making good to receive new roof treatment any type. and removal of same from site to out side of MOD land complete all as specified and directed.
M&L screed bed or bedding layer of 15mm thick in CM 1:6 for laying floor finishes in roof, finished even and smooth without using extra cement complete all as specified & as directed.
M&L painted cement plastered surfaces with one coat of cold applied bituminous primer @ 0.40 ltr/Sqm conforming to IS-3384 and laying APP based polymeric membrane not less than 3mm thick, weighing not less than 3.5kg/sqm, reinforced with polyester non woven fabric (weighing not less than 150gms/sqm) shall only be used. It shall be laid by torch application. Side over laps shall be 75mm and the end lap shall be 100mm and all over laps and joints shall be sealed by torch application. For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside the parapet groove. This shall be finished by a membrane flashing.
M&L preparation of APP based polymeric surface and applying two coat of aluminium paint all as specified & as directed.
M&L padding in PCC 12:4 type B-0 ( using 12.5mm size graded stone aggregate) laid to provide a finished slope of 1:30 finished even and smooth without using extra cement all as specified
M&L plain cement concrete type B-1, 1:2:4 (20mm graded aggregate ) in roof kerbs or mud stops, rounded or chamfered on edges
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removal of rubbish from the site complete.
M & L cutting out cracks to V section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as secified and as directed
M&L cutting groove in brick wall/ stone masonry , 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
Dismantling plain or corrugated steel / FRP sheeting any gauge, thickness including nainital or similar pattern roof /wall covering
Dismantling wrought iron or mild steel work of any description nototherwise provided for
S & F steel work in tubular/ square/ rectangular trusses incl special shaped washer etc, complete using ERW orinduction butt welded tubes conforiming toIS 1161-1979 graded St-240
M & L Preparing newly untreated steel surfaces of any descripton over 10 cm wiidth or girth and applying two coat of synthetic enamel paints over a coat of red oxide primer
M&L pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified
S & F factory made steel window with side hung shutters factory made including box type hinges with steel handle and steel peg stay complete without glazing bars devetailed or welded incl inserting the hold fast in stone masonry and make good the disturbed masonary
S & F factory made steel window with side hung shutters including box type hinges with steel handle and steel peg stay complete without glazing bars all as specified
S & F factory made steel ventilator with top hung shutter including hinges, steel peg stay and handle complete all as specified
Supply only water proofing compound
S&F in repairs 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with L- type or J- type or cranked hook bolts
M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM (1:4)
S & F in repair vitreous china squatting pan 'Orissa' pattern water closet white size 580mm x 440mm with integral foot rest (excluding flushing cistern and flush pipe) complete including connection to trap and flushing pipe antisyphonage pipe etc
M & L taking down existing treatment of chajja and applying 15mm thick plastering to chajjas in CM 1:3 including making dripping/ throating and PCC 1:2:4 for covering making proper slope etc complete at ground/ first floor all as specified and as directed
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth in stone, concrete block or slab wall.
M & L plain Cement Concrete 1:4:8 type D-2 (40mm graded aggregate) in sub base of floors
M & L for preparation of old decorated surfaces of walls, pillars and cornices including brooming down and cleaning the surface and applying one coat of white wash all as specified and directed
M & L for preparation of old plastered or unplastered decorated surfaces and applying one coat of white wash on ceiling
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces incluiding filling of depressions etc and applying two coats of oil bound distemper of approved tint.
M&L of one coat of Birla wall care putty on walls etc.
M&L preparation of old plastered surface of walls and applying two coat of cement base paint
Taking down carefully surface aluminium or copper point wiring from existing recessed PVC conduits (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces of walls even and smooth using CM 1:3 as required and matching the colour with the existing surfaces.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular sunken boxes for mounting switxhes, sockets, fan regulator as required for one light point controllrd by one switch.( Note :- The cost of cutting chases in stone masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate of the concealed wiring.
All as per item No. 130.10 here-in-before but one fan point controlled by one switch
All as per item No. 130.10 here-in-before but one angle holder point controlled by one switch
All as per item No. 130.10 here-in-before but one exhaust point controlled by on switch.
All as per item No. 130.10 here-in-before but One socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 130.10 here-in-before but One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 130.10 here-in-before but One bell point controlled by on bell push button.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular metal flush boxes with modular white cover plate with frame for one socket point 16 Amps controlled by one switch on indepdendent board.
S&F angle holder 6A, 240V insulated polycarbonate body with back plate complete: Make : Anchor Cat No : 39527( Code : 51191) or equivalent as approved by GE
S&F switch modular 1 way 6 Amps, 230 volts, 1 module. Make : Legrand Mylink ™ mechanisms, Cat No : 675501 or equivalent as approved by GE
S&F modular socket 6 Amps, 2/3pin combined 2 module AC 230 volts.Make : Legrand Mylink ™ mechanisms , Cat No 6755 50 or equivalent as approved by GE
S&F modular switch 1 way 16 Amps, 230 volts, 1 module.Make :Legrand Mylink ™ mechanisms, Cat No : 6755 11 or equivalent as approved by GE
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts. Make : Legrand Mylink ™ mechanisms Cat No : 6755 55 or equivalent as approved by GE
S&F modular fan regulator 120 watts, 2-module AC 230 Volts. Make : Legrand Mylink ™ mechanisms Cat No : 6755 31 or equivalent as approved by GE
S&F Modular bell push 6A 1 module Make: Legrand Mylink ™ mechanisms Cat No : 6755 04 or equivalent as approved by GE
S&F bell, AC, 230 volts, single pole. Make : Legrand Cat No : 573443 or equivalent as approved by GE
S&F ceiling rose 3 plates polycarbonate body complete. Make: Ancher Penta Cat No : 39017 or equivalent as approved by GE
S&F modular whiter cover plate with frame and metal flush box 1/2 module. Make : Legrand Mylink ™ mechanisms Cat No: 6755 61-62 or equivalent as approved by GE
S&F modular white cover plate with frame and metal flush box 3 module. Make : Legrand Mylink ™ mechanisms Cat No : 6755 63 or equivalent as approved by GE
S&F modular whiter cover plate with frame and metal flush box 4 module.Make : Legrand Mylink ™ mechanisms Cat No : 6755 64 or equivalent as approved by GE
S&F modular white cover plate with frame and metal flush box 6 module. Make : Legrand Mylink ™ mechanisms Cat No : 6755 66 or equivalent as approved by GE
S&F modular white cover plate with frame and metal flush box 8 module. Make : Legrand Mylink ™ mechanisms Cat No : 6755 67 or equivalent as approved by GE
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories size 2X4 sqmm + 1X4 sqmm earth wire in 20 mm dia conduit.and terminnated in power socket, DBs, panel etc all as directed.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories size 4X6 sqmm + 2X6 sqmm earth wire in 25 mm dia conduit and terminnated in power socket, DBs, panel etc all as directed.
S&F 20 amp, single pole and neutral socket outlet with 2 pole and earthy, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with cchained metal cover for socket outlet with and including one number single pole 'C' series MCB 16 amp as required.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised iron strip 32 x 6 mm earth lead by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including 40 mm bore light grade G.I. protection pipe (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip
S&F in replcement MCB distribution board, powder coated, TPN , 415 volts, 4 ways,CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required. Make:-Legrand Cat No: 5076 or equivalent as approved by GE
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 amp. Make - Legrand cat ref no 408587 to 408595 or equivalent as approved by GE
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Double pole 10 to 32 amp. Make - Legrand cat ref no 4086 14 to 4086 17 or equivalent as approved by GE
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 to 63 amp. Make - Legrand cat ref no 4086 59 to 4086 61 or equivalent as approved by GE
S&F in repair LED (1.2M) smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens/21 watt at a minimum system efficacy of 2000 lumen per 21 watt and total power consumption not more than 21 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips Cat Part No : BN 021LED 10S 6500 /4000 GR S1 or equivalent as approved by GE
S&F in repair LED (0.6 M)/ 2ft smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 1150 lumens/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips Cat Part No : BN 021C LED 20 PSU CDL /NW GR or equivalent as approved by GE
S&F LED bulk head fitting 6.5 watt IP 65 & IK 08 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips Cat Ref No. WT 202W LED 6S PSU NW S2 PC or equivalent as approved by GE
S&F 10 watt LED T -lamp B-22 base (warm white/golden yellow) 1000 lumens, height 8.0 cm width 20.5. Make : Make : Philips Part No 9290018611 or equivalent in Panasonic/CG/Bajaj as approved by GE
Supply and fix eahaust fan MS body AC 230 volts of 300 mm sweep with standard accessories including providing 04 Nos fasteners 10mmx75mm long in existing wall and making suitable hole in wall complete. Make : Havells Model : Ventilair DSP or equivalent as approved by GE
Supply and fixing water heater of 25 liter capacity BEE star rating 5 in approved color, heating element 2.0 KW adjustable temperature setting knob for temparture settings between 25 degree to 75 degree centigrade, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insulation including 15mm bore 450mm long flexible PVC pipe connection for cold water supply and 15mm bore 450mm long chromium plated metallic flexible pipe connection for hot water supply complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in modular metal flush boxes with modular white cover plate with frame switches, sockets, fan regulators as required for the following :- (a) One light point controlled by one switch.
(b) One Bulb holder point controlled by one switch.
(c) One fan point controlled by one switch.
(d) One exh fan point controlled by one switch.
(e) One bell point controlled by on bell push button
(f) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(g) One socket outlet 6 amp controlled by one switch on indepdendent board.
(h) One light point controlled by two, two way switch.
S&F switch modular 2 way 6 Amps, 230 volts, 1 module.
S & F modular blanking plate 1 module.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories size 4X10sqmm+2X10sqmm earth wire in 32 mm dia conduit.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways. Make : Legrand Cat Ref No. 507610 or Schneider Cat No. A9HSND04 or equivalent as approved by GE
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways. Make : Legrand Cat Ref No. 507612 or Schneider Cat No. A9HSND12 or equivalent as approved by GE
S&F in repair LED (1.2M) smartbrite extra batten made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2500 lumens/22 watt at a minimum system efficacy of 4000 lumen per 22 watt and total power consumption not more than 40 watt including driver. It has a rated system life time of 25000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips Cat Part No : BN 021LED 25S 6500 PSU GR S1 or equivalent as approved by GE
Supply and fix LED luminary 35 watts IP 66 5700K outdoor luminary with standard accessories and making connection with existing light point with 3 core 1.0 Sqmm PVC insulated multistranded copper conductor wire including fixing the same on existing Gi bracket complete. Make Philips Cat Ref No . BRP050 LED 036 CW RI MP PCSI PSU GR or equivalent as approved by GE
Supply and fixing in replacement GI bracket made out of 32mm dia GI medium grade pipe of length 90 Cms long bend shape and size as per site requirement including 02 Nos of MS flat 40x5mm 200mm long bend to shape as required to fix the G bracket with existing wall using 04 Nos of MS fastener 10mmx100mm long with nut, bolts and washers complete.
S&F Energy meters Three phase , 240V AC, 10-60A, Accuracy cl 1.0 with LPR (Zigbee) enabled meters including suitable size of transprant pilfer proof meter Box push fit & hinge type.Make : HPL Cat No : TLPB 1529131000 OC M0 or equivalent as approved by GE
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit), PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm galvanised iron wire
M&L for complete removal of existing treatment of old external plastered surface of walls and applying priming (Seal-o-Prime) on plastered surface and two coat of weather proof exterior emulsion paint (Weather coat smooth) complete all as specified and directed.
M&L for two coat of weather proof exterior emulsion paint (Weather coat smooth) over a coat of priming (Seal-o-Prime) on new plastered surface complete all as specified and directed.
Schedule of Credit
S.R.Enterprises
M/S Chandra Mohan Bansal
UNIVERSAL INFRAPROJECT PVT LTD
Smita Constructions
J.J.ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .