Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹19.1 L+₹2.1 L (12.5%)Rejected-AOC | L2 | Rejected-AOC L2 BIDDER |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
1 May 2023, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla, Amla Depot Distt Betul (MP) 460553
Comprehensive maintenance of DG Set, EOT crane and repairs/servicing of voltage stabilisers/battery banks and battery chargers including connected MISC work at AFS Amla.
2023_MES_587813_1
8532/E8 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (AF) Amla
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
13 Jun 2023
31 Mar 2023
3 May 2023
31 Mar 2023
1 May 2023
12 Apr 2023
Amount
Comprehensive maintenance for diesel engine driven generating set by carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed for 320 KVA installed at MRS including attending to under mentioned jobs to ensure its satisfactory performance:- Existing DG -01 No Make : Kirloskar Note : Quoted Rates are deemed to be for carrying out "A" checks as under :-
Checking the fan belt and adjusting tension
Checking the fuel and oil filter
Checking the air filter including cleaning and refixing
Checking of FIP oil level
Tightening the base bolts and nuts
Checking the coupling bolts and adjustment checking the self starter and Dynamo
Checking the battery distilled water levels and topping upto the required level.
Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed.
Checking the anti vibration mounting and adjusting the bolt.
Checking the radiator and radiator hose and arresting leak if any
Checking the engine oil level and topping upto the required level
NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
(ii) Servicing of DG set alongwith connected Alternator and Panel Board including 'A' check of the Engine shall be carried out once in two month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 60 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required in that period except in case of major repairs.
(iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted .
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) List of checks to be carriedout under 'A' check is attached to the Particular specifications.
Comprehensive maintenance of DG set 160 KVA installed at Malanjhari pump house including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed in Srl Item No 1.
Comprehensive maintenance of DG set 125 KVA installed at Gurth complex including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Gurth complex including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at 14TS including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Filter house including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Kudmud pump house including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 82.50 KVA installed at ST area STP including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 82.50 KVA installed at BT area STP including attending to jobs as mentioned under item No. 1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 40 KVA installed at STP including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 30 KVA installed at MGR including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 30 KVA installed at AFNET Site II including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at IMMOLS including attending to jobs as mentioned under item No.1.01 to 1.16here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at GURTH including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at 3AFH including attending to jobs as mentioned under item No.1.01 to 1.16here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at Site 'C' including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Comprehensive maintenance of DG set 10 KVA installed at 3AFH including attending to jobs as mentioned under item No.1.01 to 1.16 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "A" checks as detailed above.
Maintanance and servicing of following Diesel Generator sets by carrying out routine 'B' check of the engine complete for smooth functiuning all as per manufacturer's instructions and as directed for 320 KVA installed at MRS. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out "B" checks as under.
NOTES:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier as directed by Engineer-in-Charge. Servicing of DG Set alonwith connected Alternator and Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and contractor shall be responsible for the smooth functioning of the DG Set for a period of 60 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs.
(iii) Spare parts , engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item.
(iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item.
(v) List of checks to be carriedout under 'B' check is attached to the Particular specifications.
Comprehensive maintenance of DG set 160 KVA installed at Malanjhari pump house including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 125 KVA installed at Gurth complex including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Gurth complex including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at 14TS including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Filter house including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at Kudmud pump house including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 82.50 KVA installed at ST area STP including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 82.50 KVA installed at BT area STP including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 40 KVA installed at STP including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 30 KVA installed at MGR including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 30 KVA installed at AFNET Site II including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Mahindra Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at IMMOLS including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at GURTH including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at 3AFH including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 25 KVA installed at Site 'C' including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of DG set 10 KVA installed at 3AFH including attending to jobs as mentioned under item No.18.01 to 18.05 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Checking the tappet clearance and adjustment of valve including replacement of tappet gasket for following DG Sets :-
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 25 to 40 KVA
Supply only fuel filter pre and secondary including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply only lube oil filter including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply only air filter element including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set )
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply only fan belt of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply only Radiator hose with clip of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply only rubber coupling of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply and toping up the following items for the DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
Engine oil 20 W 40
Distilled water
Coolant
Benzo bolt with washer
Jubilee clamp for fuel pipe
Fuel Flexible pipe with brass or GM adaptor
Oil Flexible pipe with brass or GM adaptor
Flexible reinforced pressure pipe 3/8" dia.
Flexible reinforced pressure pipe 1/2" dia.
Flexible reinforced pressure pipe 1" dia.
Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold for following DG sets including removing of existing asbestos rope or any other type of insulation.
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply and fixing of Expansion bellow for exhaust manifold for following DG sets includung removing of existing
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Draining the engine oil from sump removing the sump cover cleaning the sludge and refixing the same including replacement sump gasket and filling oil for the following Gen sets as per manufactures instructions
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Dismantling the fuel pump from the Engine, transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve, plunger, copper washer etc all as required including re-calibration, refixing and testing complete.
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Dismantling the water pump from the Engine and supply and fixing new water pump of existing size and testing complete.
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Dismantling the fuel AC pump from the Engine and supply and fixing new fuel AC pump of existing size and testing complete.
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Draining out the diesel tank, cleaning / washing out the sludge and re-filling with diesel for following DG set:-
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 82.5 to 125 KVA
DG Set of capacity 10 to 40 KVA
Taking down radiator, servicing, cleaning of with suitable reagent, washing thoroughly,arresting leakage if any by welding / brazing and refixing the same (Necessary coolant and distilled water required will be measured and paid seperately under Sch item Nos 42 herein before).
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Removing and replacing of Fuel injector pipe for following DG set
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Heating and varnishing of alternator for following DG set
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply and replacement of anti vibration mounting pad for following DG sets including removing of existing .
DG Set of capacity 320 KVA
DG Set of capacity 160 KVA
DG Set of capacity 100 to 125 KVA
DG Set of capacity 10 to 40 KVA
Supply and replacement of the following items for DG set any capacity
Oil pressure gauge.
Battery terminal socket GM including soldering.
Battery terminal leads complete with brass connector
Radiator Cap
Fuel Tank Cap with Lock
Door lock of any type and size complete Set.
Door gasket of any type and size complete set.
Carbon brushes for charging alternator
PT Pump repair Kit
Replacement of AVR Suitable for 320 KVA Alternators
Replacement of AVR Suitable for 160 KVA Alternators
Replacement of AVR Suitable for 100 KVA Alternators
Replacement of AVR Suitable for 25 to 40 KVA Alternators
Supply and replacement of the following items for DG set control panel of any capacity
AC Ammeter digital type
AC Volt meter digital type 0 to 500 volt.
Frequency meter
DC Volt meter 0 to 24 V
lgnition switch with key for on, off and run.
DIN Rail for fixing MCB
MCB SP 6-32 Amps
MCB 4P 63 Amps
Indicator lamp for panel board as per existing size.
No Volt Coil suitable for 3 phase power contactor 160-200 Amps ratings
Dash board pilot lamp.
Control cable 2.5 sqmm copper Multistranded.
Control cable 4 sqmm copper Multistranded.
Toggle Switch 15 Amps
AMF Relay 12 Volt DC
Battery charging alternator 12 Volt
Temperature Gauge with sensor
Electronic governor
RPM Meter
Door hinges
Oil Pressure Sensor
AMF Panel relay
Battery charger AC to DC
Single phase preventor
Speed control sensor
Electro Timer with NO/NC
ON/OFF Delay Timer, 240V
Gen Set Control Unit
Push button type Start / Stop Switch,
Auto/Manual Switch,
Fuel gauge as per existing
Removing dismantling and overhauling of 12 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed.
Removing dismantling and overhauling of 24 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed.
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 100 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed ( Make : Amaron, Exide)
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 150 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed ( Make : Amaron, Exide)
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 180 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed ( Make : Amaron, Exide)
Supply & fix in repair MCCB 03 Pole, 415 V, Rating 200 Amp 36 KA Breaking capacity , 50 Hz with thermal magnetic release complete all as specified .
Supply & fix in repair MCCB 03 Pole, 415 V, Rating 63 Amp, 16 KA, 50 Hz with thermal magnetic release .
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 180 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed ( Make : Amaron, Exide)
S&F in repair contactor coils and spare kits as per the given capacity :-
Coil for contactors MCX11-12 Cat no CS94009
Coil for contactors MCX21-22 Cat no ST91291F000
Coil for contactors MCX31-34 Cat no. CS94196
Spare contact kit MCX11 Cat no. CS94077
Spare contact kit MCX12 Cat no. CS94078
Spare contact kit MCX21 Cat no. CS94330
Spare contact kit MCX22 Cat no. CS94331
Spare contact kit MCX31 Cat no. CS94081
Spare contact kit MCX32 Cat no. CS94082
Spare contact kit MCX33 Cat no. CS94083
Spare contact kit MCX34 Cat no. CS94084
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with top edge of the earth p;late at a depth not less than 1.5 m below niormal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25x4 mm bolted (with GI nuts, bolts and check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc at the other end including 32mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I including earthing resistence testing report submit in sub division by the contractor complete all as specified and directed.
Maintenance / servicing / load testing of EOT Crane flame proof type of 02 TON Capacity complete along with control panel to ensure smooth and trouble free operation all as specified and as directed. ( Note :- (a) Any break down of EOT will be attended by the contractor within 24 hrs on receipt of complaints from MES through telephonic / written message. (b) Serviceable certificate of crane will be submitted by the contractor . (c) Load testing of Crane will be done on Half yearly Basis and load test certificate submit to AGE E/M office by the contractor ) .
Maintenance / servicing / load testing of EOT Crane flame proof type of 05 TON Capacity complete along with control panel to ensure smooth and trouble free operation all as specified and as directed. ( Note :- (a) Any break down of EOT will be attended by the contractor within 24 hrs on receipt of complaints from MES through telephonic / written message. (b) Serviceable certificate of crane will be submitted by the contractor . (c) Load testing of Crane will be done on Quarterly Basis and load test certificate submit to AGE E/M office by the contractor) .
Maintenance / servicing / load testing of HOT Crane of following Capacity complete to ensure smooth and trouble free operation all as specified and as directed. Note :- (a) Any break down of HOT will be attended by the contractor within 24 hrs on receipt of complaints from MES through telephonic / written message. (b) Serviceable certificate of crane will be submitted by the contractor . (c) Load testing of Crane will be done on half yearly basis and load test certificate submit to AGE E/M office by the contractor)
HOT 02 Ton Capacity
HOT 05 Ton Capacity
Supply only following spares required for replacement during the process of Servicing/ repair the EOT Crane flame proof type of 02 TON Capacity :-
Gear wheel of EOT crane capacity 02 Ton
Flame Proof Rotary Limit switch
Coupling for EOT crane ( cap 02 Ton )
Electrical Contactor 25 Amp
Over Load Relay, 2.5-6 Amp
Supply only following spares required for replacement during the process of Servicing/ repair the EOT Crane flame proof type of 05 TON Capacity :-
Gear wheel of EOT crane capacity 05 Ton
Flame Proof Rotary Limit switch
Coupling for EOT crane ( cap 05 Ton )
Electrical Contactor 25 Amp
Over Load Relay, 2.5-6 Amp
Labour only for Maintenance & servicing of Voltage stabiliser of the following capacity complete. (Note : - (a) Opening top cover carefully without damaging any part and detecting the fault/defects in core by testing . (b) Test Report of voltage stabilizer will be submitted by the contractor . )
All as per above but 75/100 KVA . Make : Power wear / Volina .
All as per above but 150 KVA . Make : Power wear / Volina .
All as per above but 250 KVA .Make : Power wear / Volina .
Disconnection of LT cable connection & earthing strip , taking down to Voltage stabiliser of the following capacity for repair work/labour only for replacement of barrier assembly/ limbs complete. (Note : - (a) Transportation of voltage stabiliser from site to workshop for repair and transporting back after repair. (b) Opening top cover carefully without damaging any part and detecting the fault/defects in core by testing . (C) Reassembling, reinstallation at original location or as directed including restoration of electrical connection and testing on load complete all as specified and as directed. (d) Test Report of voltage stabilizer will be submitted by the contractor.
All as per above but 75/100 KVA . Make : Power wear / Volina .
All as per above but 150 KVA . Make : Power wear / Volina .
All as per above but 250 KVA .Make : Power wear / Volina .
Supply only following spares required for replacement during the process of Servicing / Repair the voltage stabiliser capacity 75 to 250 KVA :-
Micro toggle switches with manual increase/decrease push switches Make : Kaycee / Essan / Gay Lord.
Indicator of Main/High & Low voltage Make : Harry / Vaishno
Push button Make: Kaycee / Essan / Gay Lord.
Auto manual switches Make: Kaycee / Essan / Gay Lord.
Supply only following spares required for replacement during the process of Servicing / Repair the voltage stabiliser capacity 75/100 KVA :-
Electronic sensing card PCB with copper wiring ( FRLS ) complete Make : AE / INTEC / Volina / Blue hill / Vinitee or Make approval by GE .
Rotary mechanism of dimmer through armature motor Make: AE / Volina / Vinitee or Make approval by GE.
Dimmer with super enamel copper wire complete as per existing size / type / gauge.
Servo Motor single phase, 230 volts, 50 Hz , Make : AE / Volina / Vinitee or Make approval by GE .
Supply only following spares required for replacement during the process of Servicing / Repair the voltage stabiliser capacity 150 KVA :-
Electronic sensing card PCB with copper wiring ( FRLS ) complete Make : AE / INTEC / Volina / Blue hill / Vinitee or Make approval by GE .
Rotary mechanism of dimmer through armature motor Make: AE / Volina / Vinitee or Make approval by GE .
Dimmer with super enamel copper wire complete as per existing size / type / gauge.
Servo Motor single phase, 230 volts, 50 Hz , Make : AE / Volina / Vinitee or Make approval by GE .
Supply only following spares required for replacement during the process of Servicing / Repair the voltage stabiliser capacity 250 KVA .
Electronic sensing card PCB with copper wiring complete Make : AE / INTEC / Volina / Blue hill / Vinitee or Make approval by GE .
Rotary mechanism of dimmer through armature motor Make : AE / Volina / Vinitee or Make approval by GE .
Dimmer with super enamel copper wire complete as per existing size / type / gauge .
Servo Motor single phase , 230 volts, 50 Hz , Make : AE / Volina / Vinitee or Make approval by GE .
M&L for Oil filtration of Servo voltage stabilizers to achieve di-electric strength more than 40 KV with suitable filtration machine at specified temperature.
Toping up of new Stabilizer oil Make : BP / Savita / Power oil . Note : Value of oil should not less than dielectric strength 50 KV .
M&L for preparation of old painted steel surface such as DG Set, Crane, voltage stabilizer etc. of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint using spray machine on steel surface surfaces complete all as specifed Make - Asian Paint, Berger, Nerolac.
M&L for circuit control copper wiring as per existing gauge voltage stabilizers of the following capacities .
capacity 75/100 KVA
capacity 150 KVA
capacity 250 KVA
Supply and fix in repair MCCB 04 pole, 415 V rating 400 Amps, 36 KA, 50 Hz with thermal magnetic release.
Supply and fix in repair MCCB 04 pole, 415 V rating 200 Amps, 25 KA, 50 Hz with thermal magnetic release.
Supply and fixing in repair of Volt/Amp/PF meter, 230 volt, 50 Hz including wiring and testing complete. Make - L&T/AE.
Supply and fixing in repair Rotary switch 5 Amp for R.Y.B phases of OEM make for the voltage stabilizer complete all as specified and directed.
Supply and fixing in repair rubber gasket as per existing capacity of voltage stabilizers complete all as specified and directed.
Supply, connecting & testing of Battery rating 12 volts capacity 26 AH complete all as specified and directed by Engr-in-charge. Make - Exide/Amron/Tata Green
Supply and Fix in repairs Flame proof wheather proof 4 pole 40 Amp 415 Volts 50 Hz Rotary Switch LM 6 construction cast aluminium alloy with cable entries at bottom including flame proof cable gland and lugs etc complete all as specified and directed by Engr-in-Charge.
S&F in repair battery bank of 30 volts DC 100 AH maintenance free wet cell battery tubular type, for auxillary supply to protection system of 11 KV panels at Sub Stations inclduing inter connections with suitable copper cable with lugs including suitable size of battery box powder coated CRCA sheet 1.6mm thick with locking arrangement including testing complete all as specified and directed. Make of Battery : Exide/AMARON/TATA GREEN
Supply, install and testing of SMPS battery charger input voltage 160-290V AC, output voltage 12/24 Voltd DC with digital display voltage and current, charging current 5/10 Amps including copper wire 3 core with plug top including protection : Auto Start/Auto cut/Fuse blow/Battery reverse/AC short circuit/overload sahut down all as specified and directed. Make of Battery charger : Power tech solutions Pvt Ltd/Universal Industrial Products/Armo Electronics & Electricals, Nagpur.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
M/s Shree Ganesh Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .