| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹41.9 L+₹2.5 L (6.44%)Rejected-AOC ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹43.3 L+₹4.0 L (10.1%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹45.6 L+₹6.2 L (15.8%)Rejected-AOC | L4 | Rejected-AOC REJECTED |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
23 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
8251/E8
2022_MES_559463_1
GE/TVl/8251
Open Tender
Miscellaneous Works
Item Rate
180 days
Ramnad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹78,000
Yes
28 Jan 2023
22 Oct 2022
25 Nov 2022
22 Oct 2022
23 Nov 2022
9 Nov 2022
25 Oct 2022 - 1 Nov 2022
Amount
Material and labour complete removal of existing treatment including preparation of wall surfaces and applying two coats of oil bound distemper over coat of alkaline resistant primer over a coat of 3mm wall care putty complete all as specified and as directed.
Material and labour complete removal of existing treatment including preparation of ceiling surfaces and applying two coats of oil bound distemper over a coat of alkaline resistant primer all as specified and as directed.
Identifying and marking carefully the damaged concrete/plaster by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beam/column etc with power/hand driven chisel as directed by Engr-In-Charge upto 15mm average depth including saw cutting of all edges making square shoulders of the cavities including all as specified and as directed. (All loose unsound and cracked concrete shall be removed outside MD land)
Mixing and applying SBR latex modified cement mortar 15mm thick in cement sand mortar in proportion of 1:3 (1 cement and 2 graded quartz aggregate) with polymer admixed in proportion as approved including troweling with wooden tools on prepared concrete surfaces of parent material complete all as specified and as directed. (Note: Acrylic polymer shall be paid for separately)
Supply only approved SBR latex from FORSOC/BASF/ DR Fixit/ Sika for SBR latex modified cement mortar (Note Rate shall be in terms of solid contents of polymer)
Material and labour Preparation of new plastered surfaces on wall and applying two coats of weather proof exterior acrylic paint over a coat of alkaline resistant primer of camouflage pattern all as specified and as directed.
Material and labour complete removal of existing treatment including preparation of wall surfaces and applying two coats of weather proof exterior acrylic paint over a coat of alkaline resistant primer of camouflage pattern all as specified and as directed.
Material and labour preparation of old decorated wooden surfaces of any description over 10cm in width of girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Supply and fixing for Wiring for Circuit / Sub main Wiring of size 4 x 16.0 sq.mm along with earth wire of size 2 x 16.0 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 40 mm dia including taking down old unserviceable cable complete all as specified and as directed.. Note : (i) Four runs of main cable , two runs of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
Supply and fixing for Wiring for Circuit / Sub main Wiring of size 4 x 10.0 sq.mm along with earth wire of size 2 x 10.0 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 32 mm dia /casing capping including taking down old unserviceable cable complete all as specified and as directed.. Note : (i) Four runs of main cable , two runs of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
Supply and fixing for Wiring for Circuit / Sub main Wiring of size 2 x 6.0 sq.mm along with earth wire of size 1 x 6.0 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 25 mm dia including taking down old unserviceable cable complete all as specified and as directed.. Note : (i) Two runs of main cable , one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
Supply and fixing for Wiring for Circuit / Sub main Wiring of size 2 x 4.0 sq.mm along with earth wire of size 1 x 4.0 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 25 mm dia including taking down old unserviceable cable complete all as specified and as directed.. Note : (i) Two runs of main cable , one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
Supply and fixing for Wiring for Circuit / Sub main Wiring of size 2 x 2.5 sq.mm along with earth wire of size 1 x 2.5 sq.mm, Single Core, PVC insulated copper conductor FRLSH Cable in recessed PVC Conduit of 25 mm dia including taking down old unserviceable cable complete all as specified and as directed.. Note : (i) Two runs of main cable , one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
Material and labour for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends and cutting chases for concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed..
Supply and fix sheet metal enclosure VTPN 6 way DB suitable for MCCB Incomer upto 250 A MCCB, IP 43 , IK 09 powder coated double door, factory made and conforming to IS : 8623, ,provided with insulated vertical phase bus-bars ,neutral bar/s with shroud/s ,earth bar/s , sticking saddles ,cement spill protector ,color-coded interconnecting wire set ,cable ties , blanking plates and circuit identification labels. including , disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure VTPN 6 way DB suitable for MCCB Incomer upto 125A MCCB, IP 43 , IK 09 powder coated double door, factory made and conforming to IS : 8623, ,provided with insulated vertical phase bus-bars ,neutral bar/s with shroud/s ,earth bar/s , sticking saddles ,cement spill protector ,color-coded interconnecting wire set ,cable ties , blanking plates and circuit identification labels. including , disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 6 way DB suitable for MCB Incomer upto 63 A, IP 43 , IK 09 ,provided with insulated vertical phase bus-bars ,neutral bar/s with shroud/s ,earth bar/s , sticking saddles ,cement spill protector ,color-coded interconnecting wire set ,cable ties , blanking plates and circuit identification labels. including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, TPN 4 way DB ,415 V with Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, all as specified and as directed.
Supply and fix in repair sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
Supply and fix in repair Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one DP MCB 20 Amps, 240 volts (for AC ) complete all as specified and directed.
Fixing only Single Phase Energy meter including necessary wiring required to connect input and output connection from & to the nearby distribution board. Note:- Energy meter will be issued under Schedule -B free for fixing.
Supply and fix three phase electronic meters temper proof LCD display with polycarbonate cover 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS13779 , IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed..
Supply and fix 4 Pole MCCB 200 A, breaking capacity 25 kA with Thermal - Magnetic Release including taking down old unserviceable MCCB complete all as specified and as directed..
Supply and fix 4 Pole MCCB 63 A, breaking capacity 16-18 kA with Thermal - Magnetic Release including taking down old unserviceable MCCB complete all as specified and as directed..
Supply and fix MCB TPN 63 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TPN 40 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TPN 32 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 32 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SP 5 A to 32 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fixing Rechargeable Inverter type LED lights fitting 20W, 240V Cool day light with Li-ion battery 2600 mAh complete all as specified and directed Including taking down old U/S fittings for taking into credit.
Supply and fixing bulb holder B22 type and connecting it existing copper wire complete all as specified and as directed..
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light and connecting up LED light fitting with flexible copper conductor cable of suitable size to the ceiling rose complete. all as specified and directed Including taking down old U/S fittings for taking into credit.
Supply and fixing LED light fitting type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and connecting up LED light fitting with flexible copper conductor cable of suitable size to the ceiling rose complete. including taking down old U/S fittings for taking into credit .
Supply and fixing LED light fitting 1x9W/1X10Wbulkhead luminaries including LED light driver holder and connecting up LED light fitting with flexible copper conductor cable of suitable size to the ceiling rose complete. all as specified and directed including taking down old U/S fittings for taking into credit.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 25×4mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers as shown in electrical plate No.3 in SSR 2009 Part I Specification, in PCC1:3:6 type C1, RCC M25 type cover slab as shown in electrical plate No.3 in SSR 2009 Part I Specification 30mm thick with 6 mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge
Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicated situation for loop earthing etc of galvanised steel earth strip of size 25 x 4 mm including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and fix FRLS rigid PVC Conduit 32mm/40 mm with spring and flap set on both sides through the thickness of wall after making hole in the wall and making good the wall surface complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing LED building security light fitting 20 Watt with inbuilt driver , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant, polycarbonate optical cover, IP65 , IK07 , with surge protection level upto 4 kV , luminous flux (system flux) 95 lm , LED luminaries efficacy 1900 lm/W , including taking down old unserviceable light fitting.
Supply and fix new GI bracket made out of 32 mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc including removing old unserviceable GI bracket complete all as specified.
Material and labour for XLPE insulated, 3.5 Core, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, Cross-Sectional Area 120 sq.mm complete all as specified and directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type soil, complete all as specified
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil, complete all as specified
Material and labour for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable as specified. for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and lay bricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to the length of the brick complete all as specified and directed.
Supply and fix ON Load Change over switch 415V 4 pole 200 Amps in sheet metal enclosures conforming to IS : 13947 (Part-3) - 1993.with cable gland, auxiliary switch and spreader links as applicable to frame size and connecting the cables at input & output terminal with proper lugs.
Material and labour for 80mm bore `light grade` galvanised tubes with all fitting, laid in trenches complete all as specified and as directed by the Engineer-in-Charge
Material and labour for horizontal direction boring under road for laying 80 mm dia GI Pipe at a depth not less than 450 mm and not exc. 800 mm complete all as specified. Note : The rate is inclusive of all the materials, equipments and labour required for doing trenchless horizontal boring under the road, nothing extra shall be admissible on any account then the rates quoted above.
Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
JR ENTERPRISES
PHEJAYS AGENCIES
AnnaiEnterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .