GE Lalgarh Jattan
REPAIR / MANIT OF EXISTING UNSERVICEABLE LUMINARIES INCLUDING DAY TO DAY COMPLAINTS FOR OTM ACCN AND MISC ACCN AT LGJ MIL STN
2024_MES_665049_2
8935-15/GE/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹60,000
Yes
13 Dec 2024
26 Sept 2024
21 Oct 2024
26 Sept 2024
19 Oct 2024
5 Oct 2024
Amount
Taking down old U/S carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good distrubed surfaces of walls and floors etc to match with the existing all as specifided and directed by Engineer-in-Charge.
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed surfaces to match with the existing surfaces all as specified and directed by Engr-in-Charge.
M&L for concealed Point wiring one light point controlled by one, one way switch with single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakeliteplastic laminated sheet top cover with brass counter shunk screws with washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour all as specified and directed by Engr-in-Charge.
All as per srl item No 4 here in before, but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches all as specified
All as per srl item No 4 here in before, but for One 3 pin 5 amps switch socket outlet point on independent board all as specified
All as per srl item No 4 here in before, but for One bell/buzzar point controlled by one bell push all as specified
All as per srl item No 4 here in before, but for two way point controlled by two way switch all as specified
All as per srl item No 4 here in before, but wiring with 2.5 Sqmm multistranded cable and earth wire with copper conductor of size 2.5 Sq mm for 15 amps all as specified
M&L for concealed Point wiring in replacement One ceiling/Exhaust fan point controlled by one switch and regulator with single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in existing conduit including PVC insulated unsheathed earth wire with multistanded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakeliteplastic laminated sheet top cover with brass counter shunk screws with washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour all as specified and directed by Engr-in-Charge.
Supply and fix in repair piano Switch flush button single pole one way 5/6 Amps 230 Volt AC complete all as specified and directed
Supply and fix in repair piano Switch flush button single pole two way 5/6 Amps 230 Volt AC complete all as specified and directed
Supply and fix in repair piano Switch flush button single pole one way 15/16 Amps 230 Volt AC complete all as specified and directed
Supply & fixing in repair electric buzzer ding dong 5 amp 230 volts AC supply including taking down old u/s one all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair of socket two in one, 6/5 pin 5 Amp and 230 Volt flush type all as specified & directed
Supply & fixing repair of socket two in one, 6/5 pin 5 Amp and 15/16 Amp 230 volt flush type all as specified & directed
Supply and fixing in repair LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 3 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S & F in repair Lamp holder PVC/Polycarbonate type incl LED lamp 9 watt, insulated body with back plate etc all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-In-Charge
Supply and fix in repair ceiling rose surface bakelite two to three terminals/plate, polycarbonate, isolated body complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair Switch socket combination 2 in 1, 5 A flush type complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 complete all as specified and as directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 A with box flush type complete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 with box complete all as specified and as directed by Engineer-in-charge
Supply and fixing in repair SP 6-32 Amp 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-In-Charge
All as per ser No 26 here in berofe, but SPN 63 Amp all as specified and directed
Supply and fix Vertical DB 4 way suitable for Double Pole including outgoing MCB-40 Amp-04 Nos with incoming 100 Amps MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCCB 100 Amps, 4 pole, 16 KA complete all as specified and as directed by Engineer-in-charge
Supply and fixing PVC Blanking Plates one way with internal lock complete all as specified and as directed by Engineer-in-charge.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engr in charge.
S & F modular fan regulator, 120W-2 Module complete all as specified and directed by Engr in charge.
Material & Labour for Sub Main Wiring in repair with two run single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 4 sq.mm & One run of 4 sq.mm & One run of PVC conduit with accessories shall be measured as One length complete all as specified and as directed by Engineer-in-charge.
Material & Labour for Sub Main Wiring in repair with two run single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in PVC conduit & accessories Suitable size with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engr-in-Charge. NOTE-two run of 6 sq.mm & One run of 6 sq.mm & One run of PVC conduit with accessories shall be measured as One length complete all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Supply and fixing LED light fitting as building security lights of 35 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover, incl street light bracket made out of 40 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge
Supply and fix in repair Fresh air fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 MM complete all as specified and directed by Engr-In-Charge. Old U/S Fresh air Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge.
Supply and fix in repair heavy duty exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades and fan motor of Cap at least 190 Watt or above , and frame and louvers Complete all as specified and directed by Engr-In-Charge. Old U/S exhaust Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge..
Supply, laying, testing and commissioning in repair cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed
M&L for sand cushioning with a layer of dry sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply and laying best quality locally availble Sub class 'B' bricks(old size) for cable protection cover, laid flat and lay in trenches over the cable complete all as specified and directed.
M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge.
Supply and fix GI Pipe light grade of size 40 mm laid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge
Supply and fix LED 2 ft x 2 ft 1 x 40 watt LED luminaire recess mounting flat panels with fittings recess mounting complete all as specified and directed by Engineer-in-Charge
Supply and fix LED round panel, 15 cm dia, 1 x 12 watt surface mounted LED luminaire recess mounting flat panels with fitting recess mounting complete all as specified and directed by Engineer-in-Charge
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
NATIONAL ENTERPRISES (BID ID -3130558)
Singla Electricals (BID ID -3143952)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .