Loading…
Loading…
Tender Value
₹17.8 Cr
EMD Value
₹35.5 L
Closing Date
6 Oct 2026, 11:30 am
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
14 conditions · 2 needing a document upload
10.2.The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where. V=Advertised value of the tender in crores of Rupees. N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turn over. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported byAudited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. b(1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows. The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as
Defination of Similar Work :- Execution of Panel Interlocking or Electronic Interlocking with MACLS either Indoor or Outdoor works or Both. OR Alteration to Existing Panel Interlocking / Electronic Interlocking with MACLS either Indoor or Outdoor works or Both. OR Provision of IBS works in panel Interlocking or Electronic Interlocking sections. OR Provision of Automatic signalling with Axle counter/Track circuits or both together. OR Provision of UFSBI/BPACs/Digital Axle counters at Panel Interlocking stations/Electronic interlocking stations.
9 conditions · 6 needing a document upload
IN CASE OF ADVERTISED TENDER VALUE IS MORE THAN RS. 10 CRORES, The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of IRSGCC 2019.NOTE: i)The Tenderer(s) shall furnish the details of existing commitments and balance amount of ongoing works with tenderer as per the prescribed proforma of Railway for statement of all works in progress and also the works which are awarded to tenderer but yet not started up to the date of opening of tender. In case of no works in hand, a 'NIL' statement should be furnished. This statement should be submitted duly verified by Chartered Accountant. (ii) In case, the tenderer/sailed to submit the above statement along with offer, their/his offer shall be considered as incomplete and will be rejected summarily. ( Click here to download Format)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer has to go through Technical Specification and scope of work as stipulated in Annexure - XIX of the Tender Document and comply.
As per GCC Clause 14.0 Documents to be Submitted Along withtender. (i)The tenderer shall clearly specify whether the tender issubmitted on his own (Proprietary Firm) or on behalf of aPartnership Firm / Company / Joint Venture (JV) / Registered Society/ Registered Trust / Hindu Undivided Family (HUF) /Limited LiabilityPartnership (LLP) etc. The tenderer(s) shall enclose the attestedcopies of the Constitution of their concern, and copy of PAN Cardalong with their tender. Tender Documents in such cases are to besigned by such persons as may be legally competent to sign themon behalf of the firm, company, association, trust or society, as thecase may be.
i) Following documents shall be submitted by the tenderer: (a)SoleProprietorship Firm: (i) All documents in terms of Para 10of theTender Form (Second Sheet) above. HUF: (ii)A copy of notarizedaffidavit on Stamp Paper declaring that he who is submitting thetender on behalf of HUF is in the position of 'Karta' of HinduUndivided Family (HUF) and he has the authority, power andconsent given by other members to act on behalf of HUF. (iii)Allother documents in terms of Para 10 of the Tender Form (SecondSheet) above. (c) Partnership Firm: (i) All documents as mentionedin para18 of the Tender Form (Second Sheet). (d) Joint Venture (JV):All documents as mentioned in para 17 of the Tender Form (SecondSheet). (e) company registered under Companies Act 2013: (i)Thecopies of MOA(Memorandum of Association) / AOA (Articles ofAssociation) of the company (ii)A copy of Certificate ofIncorporation (iii)A copy of Authorization/Power of Attorney issuedby the Company(backed by the resolution of Board of Directors) infavour of the individual to sign the tender on behalf of the companyand create liability against the company. (iv)All other documents interms Para 10 of the Tender Form (Second Sheet) above. (f) LPLimited Liability Partnership): If the tender is submitted on behalfof a LLP registered under LLP Act-2008, the tenderer shall submitalong with the tender: (v)A copy of LLP Agreement (vi) A copy ofCertificate of Incorporation (vii)A copy of Power ofAttorney/Authorization issued by the LLP in favour of the individualto sign the tender on behalf of the LLP and create liability againstthe LLP. (viii)An undertaking by all partners of the LLP that they arenot blacklisted or debarred by Railways or any other Ministry /Department of the Govt. of India from participation in tenders /contracts as on the date of submission of bids, either in theirindividual capacity or in any firm/LLP or JV in which they were / arepartners/ members. Concealment /wrong information in regard toabove shall make the contract liable for determination underClause 62 of the Standard General Conditions of Contract. (ix)Allother documents in terms of Para10 of the Tender Form (SecondSheet). (g)Registered Society &Registered Trust: The tenderer shallsubmit: (x)A copy of the Certificate of Registration (xi) A copy ofMemorandum of Association of Society/Trust Deed (xii) A copy ofPower of Attorney in favour of the individual to sign the tenderdocuments and create liability against the Society/Trust. (xiii)Acopy of Rules & Regulations of the Society. (xiv) All otherdocuments in terms of Para 10 of the Tender Form (Second Sheet)above (iii) If it is NOT mentioned in the submitted tender thattender is being submitted on behalf of a Sole proprietorship firm /Partnership firm / Joint Venture / Registered Company etc., then thetender shall be treated as having.
15. The tenderer whether sole proprietor / a company or apartnership firm / joint venture (JV) / registered society / registeredtrust / HUF / LLP etc if they want to act through agent or individualpartner(s), should submit along with the tender, a copy of power ofattorney duly stamped and authenticated by a Notary Public or byMagistrate in favour of the specific person whether he/they bepartner(s) of the firm or any other person, specifically authorizinghim/them to sign the tender, submit the tender and further to dealwith the Tender/ Contract up to the stage of signing the agreementexcept in case where such specific person is authorized for abovepurposes through a provision made in the partnership deed /Memorandum of Understanding / Article of Association/Boardresolution, failing which tender shall be summarily rejected. Aseparate power of attorney duly stamped and authenticated by aNotary Public or by Magistrate in favour of the specific personwhether he/they be partner(s) of the firm or any other person,shall be submitted after award of work, specifically authorizinghim/them to deal with all other contractual activities subsequent tosigning of agreement, if required. Note: A Power of Attorneyexecuted and issued overseas, the document will also have to belegalized by the Indian Embassy and notarized in the jurisdictionwhere the Power of Attorney is being issued. However, the Powerof Attorney provided by Bidders from countries that have signedthe Hague Legislation Convention 1961 are not required to belegalized by
As per GCC Clause No.18.10 The tenderer shall clearly specify thatthe tender is submitted on behalf of a partnership firm. Thefollowing documents shall be submitted by the partnership firm,with the tender: (i) A notarized copy of partnership deed or a copyof the Partnership deed registered with the Registrar.. (i) Anotarized or registered copy of Power of Attorney (duly registeredas per prevailing law) in favour of the individual to tender for thework, sign the agreement etc. and create liability against the firm.(ii) An undertaking by all partners of the partnership firm that theyare not blacklisted or debarred by Railways or any otherMinistry/Department of the Govt. of India from participation intenders / contracts as on the date of submission of bids, either intheir individual capacity or in any firm/LLP in which they were / arepartners/members. Any Concealment / wrong information in regardto above shall make the bid ineligible or the contract shall bedetermined under Clause 62 of the Standard General Conditions ofContract
As per GCC 2022): The tenderers shall submit a copy of certificatestating that all their statements/ documents submitted along withbid are true and factual. Standard format of certificate to besubmitted by the bidder is enclosed as Annexure-V (Annexure-V ofGCC April 2022). Non submission of above certificate by the biddershall result in summarily rejection of his/their bid (Clause 6.1 ofGCC2022 PART-I) ( Click here to download Format) ( Click here to download Format)
Tenderer has to go through the General Technical Conditions and Specifications and Drawing as stipulated in Annexure - XX of the Tender Document and comply.
Name of the Work: Hyderabad Division: Signal & Telecom arrangements (1) Reliability improvement of GWD-PASR & PASR-RC Section Block Circuits and Provision of Multi Section Digital Axle Counter (MSDAC) Complete System in dual detection to existing Track Circuits at PASR Station Yard, (2) Modification of Circuits to suit Kavach at 4 Stations i.e, BMO, FM, UR & DTP as per new policy, 3) Provision of Path Redundancy and Media Redundancy for Signalling Systems i.e, Electronic Interlocking, Automatic Signalling, MSDAC and Data Logger in Automatic Signalling Section of MED-BMO and FM-UR Sections, 4) Extension of existing RCC ABS Hut (Relay Room & Battery Room) in connection with the work of "Replacement of Track Circuit with Multi Section Digital Axle Counter (MSDAC) on STPD 'A'-KCG-FM and STPD 'B'-MJF-CVB-BMO Auto Sections", 5) Extension of existing RCC ABS Hut (Relay Room & Battery Room) in connection with the work of" Replacement of Analog Axle Counter on Loop Lines with MSDAC on entire Station at VDI, GWD, KQQ, WPR, MQN & BDHN Stations" & 6) Proposed Construction of Gate Hut (Relay Room & Battery Room) in connectio with "Interlocking of Level Crossing Gate Nos. 57, 95, 174, 231, 235 & 238".
Y-SG-36-2026-27-18~SCR
Y-SG-36-2026-27-18
Open
Works - General
18 Months
Hyderabad, Telangana
₹0
₹35.5 L
10 Sept 2026
10 Sept 2026
22 Sept 2026
346 items across 13 schedules · ₹17,76,93,993.67 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of 'E' type Lock of specified Numbers ward as per requirement with one key 'E' type Lock to Drg No. SA3376- M or latest and Specn IRS: S30-64 or latest (Inspection: RDSO). | 105.00 | — | 1,051 | 1,10,355 |
| 2 | Supply of Relay fixing frame for Full Numbers Location Box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx3mm. The frame shall have suitable holes to fix in Full Location Box (Inspection: Consignee). | 25.00 | — | 853 | 21,325 |
| 3 | Supply of Hylam sheet of size Numbers 2400mmx1200mmx6mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee). | 15.00 | — | 7,124 | 1,06,860 |
| 4 | Supply of Plug-in type miniature Numbers tractive armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip-ATC Clip and connectors as per Specns BRS 930, lRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QN1- 8F-8B, 24 V DC. The interlocking code: ABCDE (Inspection: RDSO). | 50.00 | — | 4,400 | 2,20,000 |
| 5 | Supply of Plug-in type miniature Numbers tractive armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip-ATC Clip and connectors as per Specns BRS 930, lRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNI-12F/4B, 24 V DC. The interlocking code: ABCDE (Inspection: RDSO). | 200.00 | — | 4,283 | 8,56,600 |
| 6 | Supply of 24 V DC plug-in type Numbers miniature tractive armature, AC immune Relay complete with plug board, retaining clip-ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QBCA1- 2HF/4B, Interlocking code: BCEJK as per Specns BRS 943 or latest (Inspection: RDSO). | 120.00 | — | 8,307 | 9,96,840 |
| 7 | Supply of 24 V DC plug-in type Numbers miniature tractive armature, AC immune Relay complete with plug board, retaining clip-ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1-12F/4B, DC Neutral Line Relay, Interlocking Code: ABDFH as per Spec BRS 931 A or latest (Inspection: RDSO). | 200.00 | — | 4,413 | 8,82,600 |
| 8 | Supply of Q series Magnetically Numbers Latched (QLI) type Relay, 24V DC, complete with plug board with connectors and retaining clips confirming to BRS 935A and RDSO Specn IRS S:34 & IRS 3:23 or latest - QLI-IIF/4B, The interlocking code: ABDEG (Inspection: RDSO). | 100.00 | — | 5,701 | 5,70,100 |
| 9 | Supply of powder coated Cable Numbers termination rack of size 880mmx 2075mm made using 50mmx50mmx6mm (6mm thickness) MS angles. The cable termination rack shall be supplied with stainless steel nuts and bolts for fixing the rack, tripod bases and reel insulators (for K rack, P rack and power rack), cable ladder of 400mm width and 2075mm length with two angles of size 40mmx 40mmx5mm (5mm thickness) and supporting flats of size 25mm x 25mm. Suitable holes shall be drilled to fit hylam sheet as per standard practice. (Inspection: Consignee). | 3.00 | — | 7,585 | 22,755 |
| 10 | Supply of Terminal block: 1 way Poly Numbers butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO Drg No. SA23745-Alt.5 or latest, SA23746-Alt.5 or latest, S23747-Alt.5 and Specns IRS: S 75- 2006 Rev.2.0 (Tentative) or latest, IRS: S 23-88 Amd. 1 or latest (Inspection: RDSO). | 1500.00 | — | 97 | 1,45,500 |
| 11 | Supply of Terminal block: 6 way Poly Numbers butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO Drg No. SA23756-Alt.3 or latest, S23757t Alt.4 or latest and Specns IRS: S75-2006 Rev.2.0 (Tentative) or latest, IRS:S23-88 Amd.1 or latest (Inspection: RDSO). | 200.00 | — | 406 | 81,200 |
| 12 | Supply of Modular Terminal Block Set (WAGO or similar) as per RDSO Specn RDSO-SPN-189-2004 Ver.3.0 or latest consisting the following parts: a) 2 conductor disconnect Terminal Block - 6 Nos.b) End- intermediate plate suitable for 2 conductor disconnect terminal - 1 No.c) Screw less end stop similar to WACO Model No. 249-117 - 2 Nos.d) Insulated jumper WAGO Model 280- 402 - 5 Nos.e) Din Rail - 0.1 metre per set (in length of 1 metre for every ten set) (Inspection: RDSO). | 440.00 | — | 703 | 3,09,320 |
| 13 | Supply of mini WSB markers for Set modular terminals WAGO Model No. or similar - 100 Nos. (Inspection: Consignee). | 335.00 | — | 64 | 21,440 |
| 14 | Supply of non-deteriorating type of Numbers fuse holders and fuse links 240V AC- DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of El fuse link type (up to 20A) - fuse holders 20A capacity (Inspection: RDSO). | 1050.00 | — | 220 | 2,31,000 |
| 15 | Supply of non-deteriorating type of Numbers fuse holders and fuse links 240V AC- DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2): 1993 knife edge type fuse of El fuse link type (up to 20A) - Fuse link 1A-2A-6A-10- 16A-20A as specified by Engineer in charge (Inspection: RDSO). | 1100.00 | — | 31 | 34,100 |
| 16 | Supply of Multi-strand, single core, Numbers copper conductor 16-0.2 (16 wires, diameter of each wire is 0.20mm) (0.55q.mm) wire coil as per Specns IS 694:2010 or latest, IRS: S 76-89 Amd.3 or latest. Length of coil should be 100m. Colour of coil to be specified by Engineer in charge (Inspection: RDSO). (Unit: one number = one coil) | 400.00 | — | 1,153 | 4,61,200 |
| 17 | Supply of Multi-strand, single core, Numbers copper conductor 28/0.3 (28 wires, diameter of each wire 0.30mm) flexible wire coil as per specifications IS 694:2010 or latest, IRS: S 76-89 Amd. 3 or latest. Length of coil should be 100m. Colour to be specified by Engineer in charge. (Inspection: RDSO) (Unit: one number = one coil) | 30.00 | — | 2,908 | 87,240 |
| 18 | Supply of 35 Sq.mm PVC insulated Metre multi-strand, single core, copper conductor 277-0.4 (277 wires, diameter of each wire is 0.4mm) cable as per IS:694 or latest, IRS: 5 76-89 Amd.3 or latest. Cable to be supplied in 100-meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO). | 2280.00 | — | 391 | 8,91,480 |
| 19 | Supply of 16 Sq.mm PVC insulated, Metre multi-stand, single core, copper conductor 127-0.4 (127 wires, diameter of each wire is 0.4mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO). | 1580.00 | — | 178 | 2,81,240 |
| 20 | Supply of 10 Sq.mm PVC insulated, Metre multi-strand, single core, copper conductor 140-0.3 (140 wires, diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil Colour to be specified by Engineer in charge (Inspection: RDSO). | 1580.00 | — | 124 | 1,95,920 |
| 21 | Supply of Remote Terminal Unit 28 Numbers digital inputs and 16 analog inputs with dual modem as per Specn IRS: S99-2006 Amd.3 or latest (Inspection: RDSO). | 5.00 | — | 3,82,594 | 19,12,970 |
| 22 | Supply of 24 pair Terminal block of Numbers Wago Make or Similar (with lever type disconnection & reconnection facility) duly fitted in CT box of approved quality, suitable for termination of cable from 0.4mm to 0.9mm conductor (Inspection: Consignee). | 10.00 | — | 3,240 | 32,400 |
| 23 | Supply of Permanently lubricated Kilometre HDPE Duct with outer diameter of 40mm and inner diameter of 33mm as per Specn RDSO/SPN/ TC/45/2013 Rev.2.0. The length of the duct shall be 1km. Two end plugs shall be provided along with the drum (Inspection: RITES). | 130.00 | — | 66,223 | 86,08,990 |
| 24 | Supply of Plastic couplers - Slip Numbers fit/push type for permanently lubricated HDPE duct. (To be procured from RDSO approved Firms (Inspection: Consignee). | 530.00 | — | 85 | 45,050 |
| 25 | Supply of End plug for permanently Numbers lubricated HDPE duct (To be procured from RDSO approved Firms (Inspection: Consignee). | 270.00 | — | 34 | 9,180 |
| 26 | Supply of Cable sealing plugs for Numbers permanently lubricated HDPE duct (To be procured from RDSO approved Firms (Inspection: Consignee). | 530.00 | — | 43 | 22,790 |
| 27 | Supply of Rotary duct cutter suitable Numbers for cutting HDPE ducts of diameter 20mm to 42mm. The duct cutter shall have a facility of replaceable blades. The blades shall be of high carbon steel (Inspection: Consignee). | 26.00 | — | 1,046 | 27,196 |
| 28 | Supply of Optical Fiber Core - Core Numbers Alignment Fusion Splicing Machine with inbuilt 5200mAh rechargeable battery. The unit provides precise core-to-core alignment with low splice loss for single and multi-mode fibers and includes auto arc calibration, high-resolution Color display, and 10000 splice data storage. With micro USB port for data backup. Accessories: Precision Cleaver with carrying case, 3-in-1 Fiber Stripper, Battery Charging Adaptor, and Alcohol Dispenser. Model: SM70s of Make: Telogica Ltd. or better, (Inspection: Consignee). | 1.00 | — | 2,59,600 | 2,59,600 |
| 29 | Supply of OTDR (37/35dB) with Numbers rechargeable Li-ion battery (6400m Ah), 7-inch TFT color display, dual USB ports, and one LAN port for data transfer. Pulse width range: 3ns-20µs; distance range: 400m- 256km; with inbuilt Visual Fault Locator (VFL). Complies with TEC Standard No. TEC 88130:2019. Model: ATL-1315Bi of Make: Telogica Ltd. or better, (Inspection: Consignee). | 1.00 | — | 1,75,230 | 1,75,230 |
| 30 | Supply of Laser Source Meter can Numbers generate an output power of 0dBm, which can be adjusted down to -7 dBm in step level as per Specn No. TEC/GR/TX/OPM-001/04/NOV-13. better; Model: DLSDT-01 of Make: Telogica or better (Inspection: Consignee). | 2.00 | — | 88,783 | 1,77,566 |
| 31 | Supply of Optical Power Meter has a Numbers detection power range of +23 dBm to -50 dBm and is equipped with rechargeable batteries. It complies with Tech Specn No. 88060:2013. The device is provided with an SC- type/2.5mm universal connector. Additionally, it includes an automatic power-off feature to conserve battery life. Model: PMDT- 012H) of Make: Telogica or better. (Inspection: Consignee). | 2.00 | — | 32,645 | 65,290 |
| 32 | Supply of Single Section Digital Axle Set Counter (SSDAC) as per Specn No. RDSO/SPN/177/2012 Ver.3.0 or latest within built event logger card (Inspection: RDSO). | 4.00 | — | 6,74,335 | 26,97,340 |
| 33 | Supply of Tool kit consisting of the Set following:a) Digital multi meter - Model 187 of Fluke make or Model Rish 18S of Rishabh Make or similar suitable for Digital Axle Counter.b) Train simulatorc) Extender cardd) Dummy Wheele) Square Drive T Handle - Model 1733 of Taparia Makef) 19mm, 3/8 inch square drive socket made of Chrome Vanadium steel - Model 19H of Taparia make or similar.g) Ring Spanner (Flat) of size 17x19mm - Jhalani Make or equivalent.h) Double ended open jaw spanner no. 895 (Deflector plates)i) Spanner of size 17x19mm - Jhalani or Everest or Taparia Make.j) Spanner of size 19x24mm - Jhalani or Everest or Taparia Make.k) Ring Spanner of size 24x26mm - Jhalani or Everest or Taparia Make.l) Screw Driver No. 902 - Taparia Make or equivalent.m) Screw Driver No. 935 - Taparia Make or equivalent.n) Carrying bag for tools(Inspection: Consignee). | 1.00 | — | 1,33,197 | 1,33,197 |
| 34 | Supply of basic material to construct Set unit Maintenance Free Earth as per Specn RDSO-SPN-197 Ver.1.0 or latest consisting of the following:a) Copper bonded steel electrode 3m long, 17mm diameter with copper bonding thickness mini 250 micron and UL listed and marked - 1 No.b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of minimum 10 kgs - 3 Nos.c) Copper strip with dimensions 150x25x6mm to terminate earth rod - 1 No.d) Copper strip with dimensions 300x25x6mm Main Equipotential Earth Bus bar (MEEB) - 1 No.e) Copper strip of with dimensions 150x25x6mm Sub Equlpotential Earth Bus bar (SEEB) - 1 No.f) 35 Sq.mm multi-strand PVC insulated Copper Cable (15 meter) (Inspection: RDSO). | 52.00 | — | 16,837 | 8,75,524 |
| 35 | Supply of Universal Locks with one Numbers steel key for every ten locks or part thereof (For example, if locks ordered is 10, 1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19) (Inspection: Consignee). | 220.00 | — | 195 | 42,900 |
| 36 | Printing, binding & supply of the Numbers following Registers with latest proforma as given by Engineer in- charge. Each Register shall be of 100 pages.1) Station Asset Register2) Deficiencies3) Officer Inspection Book4) Station Message Book5) Infringement Measurement Book for Signaling Assets6) Route Cancellation Register7) Relay Room Key Register8) Selection Circuit Testing Register9) Cable Testing Register10) Signal Maintenance Record11) Battery Maintenance Register12) Mechanical Signaling Register13) Axle Counter Maintenance Register14) SSDAC/HASSDAC/MSDAC Maintenance Register15) Block Instrument Maintenance Register16) Track Circuit Maintenance Register17) Mechanical Lifting Barriers Maintenance Register18) Electrical Lifting Barriers Maintenance Register19) Electrically Operated Point Maintenance Register20) Electronic Interlocking Maintenance Register21) Location Box Maintenance Register22) Earth Testing Record Register23) Joint Inspection of Points and Crossings Register24) Joint Inspection of Track Circuits25) Joint Inspection of Track Circuits with OHE26) Diesel Generator/Solar Panel Register27) UFSBI Maintenance Register (Inspection: Consignee).Unit: number=per register) | 1000.00 | — | 358 | 3,58,000 |
| 37 | Supply of Clip On Meter of Model Numbers Fluke 317 or similar with the following specification.1) True RMS responding.2) Voltage - DC 600V, AC 600V, DC accuracy - ±1% + 4 digit.3) AC accuracy - ±1.5% + 5 digit4) Current - DC 600A, AC 600A, AC accuracy: - ±1.5% + 5 counts, AC I DC current measurement.5) Unique 40A low frequency measurements capability with 0.01A resolution.6) Special filter circuit to enable accurate measurement of PWM output.7) Additional measurement of resistance8) Continuity check feature9) Data hold features with large, easy to read backlight display.10) Calibration certificate(Inspection: Consignee) | 3.00 | — | 20,086 | 60,258 |
| 38 | Supply of Double Walled Corrugated Numbers (DWC) HDPE duct of outer Diameter 63mm and inner Diameter 50mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The duct shall be supplied along with push-fit type O-ring coupler or end cap (To be procured from RDSO approved firms) (Inspection: Consignee). | 200.00 | — | 875 | 1,75,000 |
| 39 | Supply of Double Walled Corrugated Numbers (DWC) HDPE duct of outer Diameter 180mm and inner Diameter 153mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The duct shall be supplied along with push-fit type O-ring coupler or end cap (To be procured from RDSO approved firms) (Inspection: Consignee). | 30.00 | — | 3,827 | 1,14,810 |
| 40 | Supply of Double Walled Corrugated Numbers (DWC) HDPE duct of outer Diameter 1250mm and inner Diameter 217mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The duct shall be supplied along with push-fit type O- ring coupler or end cap (To be procured from RDSO approved firms) (Inspection: Consignee). | 30.00 | — | 6,561 | 1,96,830 |
| 41 | Supply of Cable Route Locator Numbers consists of a transmitter and a receiver, both equipped with rechargeable batteries. The transmitter (Tx) has a power output capacity of 10 watts, ensuring effective signal transmission for accurate cable tracing. The receiver is capable of providing a graphical representation on its display, enabling easy identification of the cable route. When the cable is aligned vertically on the display, the receiver automatically indicates the depth of the cable along with the current flowing through it, without requiring manual intervention. The system offers a detectable depth range of up to 10 meters. The unit is supplied with a 10-meter direct connection cable along with all standard accessories required for operation. (Model No. Tech Magix) of Make: Telogica or better; (Inspection: Consignee). | 1.00 | — | 3,77,600 | 3,77,600 |
| Schedule total | ₹2,28,94,796 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-18_1.pdf
ATTACHMENT
GCCCorrectionSlipNo-12.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
GCCCorrectionSlipNo.11.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
MakeinindiaPolicy1.pdf
ATTACHMENT
Experience.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
Acceptanceofe-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .