Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
15 Jul 2026, 1:00 pm
Similar tender results from the same govt authority in the past 3 years.
Operation, Maintenance and Repair of Electrical assets at Abhinandan Rest House, Tilak Bridge New Delhi (For Three Years)
92-SRDEE-G-DLI-2026-27
92-SRDEE-G-DLI-2026-27
Open
36 Months
New Delhi, Delhi
₹0
₹3.2 L
23 Jun 2026
23 Jun 2026
1 Jul 2026
A-Provision of Man Power for day to day Electrical Maintenance Work at
Provision of 04 no. Skilled manpower. Details as per technical scope of work (36 months x 4 skilled staff =144 man-months + leave reserve 24, Total man-month = 144+24= 168) (Unit= Man-month) & as per explanatory note and special conditions of contract.
Provision of 04 no. Un-Skilled manpower. Details as per technical scope of work (36 months x 4 unskilled staffs =144 man-months + leave reserve 24, Total man-month = 144+24= 168) (Unit=Man-month) & as per explanatory note and special conditions of contract. Above/
B-Maintenance Contract of DG sets, Transformers with switch gears and
Scheduled quarterly maintenance of 02 Nos. of Transformers of capacity 2000 KVA, 11/0.415 kV, located in substation at Abhinandan Rest House Tilak Bridge as per CAMTECH guideline including checking/inspection /rectification of bushing, transformer oil, dehydrating breather, examination for cracks & dirt deposit, dielectric strength & water content, checking of oil level and 1 ensuing proper level of oil. Items to be Inspected- Bushing, Transformer Oil & Dehydrating breather. Action required if inspection shows unsatisfactory condition- Clean or replace Bushing, Take suitable action to restore quality of oil (Payment for such suitable action like centrifuging shall be covered under other items of schedule) and Make up oil if required ( Payment for suitable action like oil supply shall be covered under other items of schedule) (02 Nos. x 04 quarters x 03 years = 24 quarters-No.) & as per explanatory note. (Unit= One-Job)
Scheduled yearly maintenance of 02 Nos. of Transformers of capacity 2000 KVA, 11/0.415 kV, located in substation at Abhinandan Rest House Tilak Bridge as per CAMTECH guideline 2 including checking/inspection/rectification of transformer oil, insulation resistance, oil filled bushing and gasket joints. Items to be Inspected- Transformer Oil, Insulation Resistance, Oil filled bushing and Gasket joints. Action required if inspection shows unsatisfactory condition -Filter or replace if not in order (Payment for such suitable action like filter supply shall be covered under other items of schedule), Process if required, Filter or replace and tighten the bolts evenly to avoid uneven pressure. (02 Nos. x 03 years = 06 year-No.) & as per explanatory note. (Unit= One-Job)
Comprehensive Annual Maintenance contract of 01 Nos. of 2000 KVA capacity of DG Set installed at Abhinandan Officers' Rest House Tilak Bridge, New Delhi comprising of Diesel Engine, Alternator, Battery & AMF/Control Panel installed. 1. The work included all type of breakdown and 3 schedule maintenance including replacement of defective materials. 2. As far as possible all maintenance and repair shall be done at site. 3.All the materials/spares shall be of OEM. 4. Replacement of fuel filter and engine oil at every service as per maintenance guide line issued by manufacturer. 5. B-check of each Engine is required to be carried out after every 300 Hrs. / 06 months working of DG sets & as per explanatory note.
Quarterly Preventive Maintenance of LT control panels, Bus duct/Bus trunking 4 systems, street lights, starter, LT switch Distribution board at different places in the substation and Abhinandan officer rest house. (As per list attached) The preventive maintenace of panels will be done as per explanatory note. (04 Qtrs x 03 Years = 12 Qtrs) (Unit= One-Job) Above/
C-Supply of Electrical Materials on requirement basis for Maintenance
Supply of PVC conduit pipe of 25 mm size conforming to IS. 9537 Part-III (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement & as per explanatory note.
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (or Latest Version) & as per explanatory note. 1x1.5 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (or Latest Version) & as per explanatory note. 1x2.5 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (or Latest Version) & as per explanatory note. 1x4.0 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (or Latest Version) & as per explanatory note. 1x6.0 sq.mm
Supply of following sizes FRLS PVC insulated multi stranded copper conductor single core cable conforming to IS 694 (or Latest Version) & as per explanatory note. 1x10.0 sq.mm
Supply of Exhaust Fan 150 mm, 230V, 50HZ, AC, Single Phase, Minimum air delivery confirming to IS: 2312:1967 or latest & as per explanatory note.
Supply of Exhaust fan, 250mm Sweep, modular plastic body, white colour, with lower 8 shutters, supply voltage 220V-240V AC, single phase, 50Hz, minimum Air delivery 800 cubic meter per hour, and conforming to IS 2312 or latest & as per explanatory note. Acceptable Makes: Bajaj, Usha, Havells, Orient, Phillips, Crompton or equivalent make.
Supply for Replacement of defective capacitor 2.5/3.5/4 Mfd: Supply of ISI marked 2.5 MFD capacitors for electric ceiling Fan to work on 230V, 50Hz confirming to IS:1709/1984 latest (reviewed 2021) & as per explanatory note. Makes: Havells/ EPCOS/ TIBCON or equivalent make.
Rewinding of all type of Fan motor as per specification & as per explanatory note.
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 1 or 2 Module
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 3 Module
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 4 Module
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 6 Module
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 8 Module
Supply of following modular base and cover plate on existing modular metal boxes etc. of the same Make as per site requirement. and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. 12 Module
Supply of LED Tubelight complete fitting with batten, (18-20 Watt), 1200 17 mm(±2%)length, Retro fitment, T- 8 type LED tube light fitting with inbuilt driver conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED based light fitting type D for Mirror area having wattage 8 to 10W 18 (approx.) complete with driver as per IS, IE rules, site requirement and prior approval of sample conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED street light fitting complete with driver (40-45 watts) CRI >= 70, SDCM 19 (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED street light fitting complete with driver (90-95 watts) CRI>=70, SDCM 20 (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of surface/recess mounted 12-15W LED Down lighter, CRI Index 70, IP 20, LED 21 Type :low power LED(<1W) P.F 0.90, cool white, die cast aluminum housing, Size 6 inch, complete in all respect, conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of recess mounted 5-6W LED Down lighter, CRI Index 70, IP 20, LED Type :low 22 power LED(<1W) , P.F 0.90, cool white, die cast aluminum housing, Size 6 inch, complete in all respect conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED light luminaries 595x595mm size, recessed mounting fitting, as per IS : 10322 having system wattage 36/40 Watt, CRI>= 80, SDCM (standard deviation color matching) <3, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement with suitable frame to avoid droping down of fitting of make Phillips, Bajaj, Havells or similar conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED single bracket 9-10 watt fitting complete, CRI >= 80, SDCM (standard 24 deviation color matching) <3 conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED double bracket 9-10 watt fitting complete, CRI >= 80, SDCM (standard 25 deviation color matching) <3 conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of LED bulk head light 10-12 watt fitting complete, CRI >= 80, SDCM 26 (standard deviation color matching) <3 conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of 05 meter LED strip of wattage 20 to 24 Watt complete with driver, CRI >= 27 80, SDCM (standard deviation color matching) <3 and as per latest IS & IE rules conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note.
Supply of ceiling rose, 3 plate conforming to IS : 371-1999 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement & as per explanatory note.
Supply of PVC Batten/Angle Holder conforming to IS : 1258-2005 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement & as per explanatory note.
Supply of following modular switch /socket on the existing modular plate & switch 30 box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. 6/10 ampere switch
Supply of following modular switch /socket on the existing modular plate & switch 31 box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. 6 ampere socket
Supply of following modular switch /socket on the existing modular plate & switch 32 box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. 16 ampere switch
Supply of following modular switch /socket on the existing modular plate & switch 33 box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. 16/6 Amp socket heavy duty with safety shutter
Supply of following modular switch /socket on the existing modular plate & switch 34 box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. Modular rotary step fan regulator
Supply of following modular switch /socket on the existing modular plate & switch box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. Modular 6 amp 35 two way Switch
Supply of following modular switch /socket on the existing modular plate & switch box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. Blanking Plate
Supply of following modular switch /socket on the existing modular plate & switch box of same Make as per site condition including connections but excluding modular plate etc. as required as per IS, IE rules and site requirement complete & as per explanatory note. DND & MMR
Maintenance of Geysers, Supply of geyser thermostat as and when required & as per explanatory note.
Maintenance of Geysers, Supply of geyser Heating element as and when required & as per explanatory note.
Maintenance of Geysers, Cleaning of Geyser Tank and repairing & as per explanatory note.
Supply of MCBs 6-32 Amp DP "C" series as per IEC 60898-1 or latest & IE rules and site requirement & as per explanatory note.
Supply of following rating and breaking capacity and pole MCCB with 42 thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. Make and model as per site requirement and as per IS/IEC 60947 or latest & as per explanatory note. 100A, 36 KA, 4 pole MCCB
Supply of following rating and breaking capacity and pole MCCB with 43 thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. Make and model as per site requirement and as per IS/IEC 60947 or latest & as per explanatory note. 63A, 36 KA, 4 pole MCCB
Supply of RCBOs 25 Amp 30/100/300 mA 2P as per requirement and IEC 61009-1 or latest & as per explanatory note.
Supply of RCBOs 40 Amp 30/100/300 mA 2P as per requirement and IEC 61009-1 or latest & as per explanatory note. Above/
D-Electrical work as and when required. 580443.20 Below/P
Manning for meeting emergency/breakdown repairs, 1 skilled staff & as per explanatory note. (Unit= Man-days)
Manning for meeting emergency/breakdown repairs, 1 unskilled staff & as per explanatory note. (Unit= Man-days)
Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per 3 IS:3043 (or latest version) including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400 mm) on top, and water pipe etc. with charcoal/coke and salt as required and provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory note.
Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) & as per explanatory note.
Detection of fault in underground HT (11 KV) / LT cable of any size by using electronic fault detection machine including digging of trench sand refilling to the original shape after laying of cable after rectification of fault & as per explanatory note.
Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS:7093 or latest /IE rules and site requirement and satisfaction to the Railway representative & as per explanatory note. 50-95 sq. mm
Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS:7093 or latest /IE rules and site requirement and satisfaction to the Railway representative & as per explanatory note. 120-185 sq. mm
Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS:7093 or latest /IE rules and site requirement and satisfaction to the Railway representative & as per explanatory note. 240-400 Sq. mm
Supply, erection, testing and commissioning of End termination of 2.0 C / 4.0 C x 70 to 240 sq. mm. LT XLPE cable as per specification. (One set means lugs in R-Y-B-N) conforming to IS:13573-1(2011) or latest & as per explanatory note.
Supply and erection of fire bucket stand as per drg. no RE/UMB/FB/SK/07 mod A 10 (Approx. wt. 51 kg) legs will be grouted with cement concrete (1:3:6 mix) size 12"x12"x18" alongwith four no. fire bucket 09ltr capacity (approx. weight 1.4 kg) per stand filled with dry flowing stand & as per explanatory note.
Supply and erection of fire extinguisher 6 kg capacity suitable for ABC class of fire 11 dry chemical powder ISI make stored pressure type initially charged with discharge hose & nozzle including fixing clamp as per IS 15683 (reviewed in 2023) and IS 4308 (reviewed in 2024) & as per explanatory note.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
List of Inventory
ATTACHMENT
SuitewiseInventoryofelectricalitems_compressed.pdf Suite wise Inventory
ATTACHMENT
SpecialConditionsofContract.pdf
ATTACHMENT
explanatorynote.pdf
ATTACHMENT
Tenderdocument-92.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
InventoryofElectricsub-stationpowersupplyequipments.pdf
ATTACHMENT
SuitewiseInventoryofelectricalitems_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid