Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC SAI VILLA C 65 EKTA NAGAR BAREILLY 243122 U P C 09 HQ CESC PUNE | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹15.7 L+₹2.8 L (21.7%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹17.4 L+₹4.5 L (35.0%)Rejected-Finance BUNGLOW 19 THE MALL KAMPTEE CANTT | KAMPTEE CANTT | NAGPUR | MAHARASHTRA | 441001 | L3 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Military Engineer Services, Garrison Engineer, Kamptee 441001
REPAIR TO SEWAGE LINE, SEPTIC TANKS AREA DRAINAGE AND OTHE RELATED WORKS AT MD ACCN AREA UNDER AGE B/R-I AT GE KAMPTEE
2025_MES_704406_1
8774/E8
Open Tender
Civil Works
Item Rate
270 days
Kamptee
All as per NIT
8 documents required · 8 mandatory
₹500
GE Kamptee
₹40,000
Yes
16 Jun 2025
15 Apr 2025
21 May 2025
15 Apr 2025
19 May 2025
29 Apr 2025
Amount
Demolition and breaking up drain pipes (salt glazed ware, AC or RCC Pipes) of any description and size set in cement mortar complete all as specified and directed.
M&L for concrete bed in PCC 1:3:6 type C2 (using 40mm graded stone aggregated) to drain pipes including packing under and haunching against the sides of the pipes after laying & testing for any dia of pipes complete all as specified and directed.
M&L for SGSW (Grade 'A') drain pipes confirming to IS size 150mm laid in trenches and jointed in CM 1:2 complete all as specified and directed.
M&L for reinforced concrete pipes, class NP2, laid and jointed complete with collar for the 200mm internal dia of pipes complete all as specified and directed.
All as per item No 4 above but 300mm dia complete all as specified and directed.
All as per item No 4 above but 450mm dia complete all as specified and directed.
All as per item No 4 above but 600mm dia complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft/loose soil.
All as per item No 8 above but depth exceeding 1.5m and not exc 3.0 m depth complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) not exc 50m and deposited where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200mm internal dia of pipe complete all as specified and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete incl demolition of brick work built in cement mortar all as specified
M&L for half brick thick brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:4 incl demoltion of brick work in cement mortar complete all as specified
M&L for 15mm thick plaster in CM 1:6 on fair face of brick walls finished even and smooth without using extra cement complete all as specified
M&L for preparation for new surfaces of wall applying two coat of cement base paint on wall over chalk whiting etc complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (using 20mm graded stone agg) as in slab and shelves supported on walls incl demolition of reinforeced cement concrete of any description and in any position all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L form work to soffits of suspended slab such as roof slab and similar work n. exc 200mm thick (horizental or sloping) rough finished flat surface all as specified
M&L for providing cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping benching, bed plates and the similar including, weathering, slightly rounded or chamfered edges and throating complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for dewatering of soak well or sewage pit of any dia and depth manually or by using pump and removal of sludge if any to a distance exc 1.5Km but n. exc 5Km out of MoD land complete all as specified and directed
M&L for removing of small vegetation /bushes /roots /plants/grass etc from any position of buildings and removel of rubbish to a distance exc 50m and including making good disturbed surface by repair work including matching with the existing surface complete all as specified and directed
M&L for Opening of manhole covers, taking out sludge from septic tanks, inspection chambers, manholes by removing sludge in solid, semi solid state or liquid state by manually or by pressure pump including removal of sludge to a distance exc 1.5Km but n.exc 5Km out of MoD land complete all as specified and directed (Note : Measurements will be taken only after dewatering of the septic tank and no extra payment will be made for dewatering the same)
S&F in repair CI oval access doors or eye pieces with required bolt and rubber gasket suitable for 100mm bore CI pipe complete all as specified and directed
M&L for cleaning of SGSW / RCC Pipe 150mm internal dia of any depth by rodding or by using pressure pump completely including manholes and removal of sludge to a distance exc 1.5Km and n.exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of SGSW/RCC Pipe 100mm internal dia of any depth by rodding or by using pressure pump completely including man holes and removal of sludge to a distance exc 1.5Km and n. exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of RCC Pipe 200 mm internal dia of any depth by rodding or by using pressure pump completely including manholes and removal of sludge to a distance exc 1.5Km and n.exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of RCC Pipe 300 mm internal dia of any depth by rodding or by using pressure pump completely including manholes and removal of sludge to a distance exc 1.5Km and n.exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of blocked drain Upto depth 1.50 m by removing sludge and flush with water and removal of sludge to a distance exc 1.5Km and n. exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of blocked drain depth exc 1.50 m by removing sludge and flush with water and removal of sludge to a distance exc 1.5Km and n. exc 5Km out of MoD land complete all as specified and directed
M&L for cleaning of blocked WC and SWG Pipe line upto 1st manhole any depth by rodding or by using pressure pump completely including 1st manhole and removal of sludge to a distance exc 1.5Km and n. exc 5Km out of MoD land complete all as specified and directed
M&L for 75mm thick PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in plinth protection/path laid in panels, finish the top surfaces even and rough to receive tile etc incl demolition of cement concrete 75mm thick as in plinth protection/path complete all as specified and directed
Taking down of PVC, pipes of any size or pattern including all fittings etc complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed
S&F in repair 110mm bore PVC (SWR) junction single (single T) equal or unequal with oval access door 110mm dia, jointed with approved adhesive complete all as specified and directed
S&F in repair PVC (SWR) bend 110mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed
S&F in repair PVC (SWR) pipe 75mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to wall complete all as specified and directed
S&F in repair 75mm bore PVC (SWR) junction single (single T) equal or unequal with oval access door 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed
S&F in repair PVC (SWR) bend 75mm dia, any radius as required and jointed with approved adhesive complete all as specified and directed
S&F in repair PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe in run lead with dia of outlet 75mm complete all as directed
S&F stack clamp out of 50mm x 5mm flat iron and 16mm dia round iron stays incl bolts and nuts and securing ends of stays to wall and roof for 75mm dia bore pipe complete all as specified and directed.
S&F stack clamp out of 50mm x 5mm flat iron and 16mm dia round iron stays incl bolts and nuts and securing ends of stays to wall and roof for 100mm dia bore pipe complete all as specified and directed
S&F in repair Plastic water closet seat cover , white colour closed pattern with flat bottom and mild steel chromiuim plated hanging divice for EWC.
S&F in repair Vitreous chine wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair vitreous china water closet Orissa pattern of size 580 X440mm white ISI marked with cast iron 'P' or 'S' trap including provn of cement concrete bedding including connections to flushing cistern/pipe and making good disturbed portion to match existing surfaces complete all as specified.
S&F in repair PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action push type with inlet ball valve and float including flush pipe long 32mm dia, ball valve, handle, bracket etc complete all as specified and directed.
S&F in repair PVC connection 15mm bore dia 450mm long with 2 Nos PTMT nuts with washer complete all as specified
S&F in repair PVC (SWR) floor trap with grating including jointing with solvent cement to waste pipe in run lead with dia of outlet 75mm complete all as directed
S&F in repair flush pipe of polythene of low or high density 32 mm PVC for low level flushing cistern complete all as specified and directed.
Dismantling of unserviceable floor, hearth or wall tiling incld cement mortar bedding (but not backing) and removal of rubbish/ debris from premises of MOD Land complete all as specifed and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile n exceeding 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:4 finished fair and even for laying floor finishes/ tiles etc complete all as specified and directed.
M&L for coloured Glazed ceramic tiles in vertical surfaces 350x250 x7mm / 450 x 350x 7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over 10mm thick rendering or bedding layer of cement mortar 1:4 incl dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11Sqm but n. exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 incl 25mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floor finished rough to receive floor/screed incl demolition of cement concrete floor 40mm thick complete all as specified and directed
S&F for 15mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor incl taking up or down 15mm dia bore of galvanised iron steel tubing and connections including cleaning for refixing, cutting in wall/floor complete all as specified
Refixing only 15mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified
S&F for 20mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor incl taking up or down 20mm dia bore of galvanised iron steel tubing and connections including cleaning for refixing, cutting in wall/floor complete all as specified
Refixing only 20mm bore dia of medium grade galvanised steel tubing with all fittings and fixed complete to wall or laid in floor complete all as specified
NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 18,200.00]
M/s DS Khekde (BID ID -3291669)
M/s T.S.JOHAR (BID ID -3300417)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .