EE, BCD, Building Division, Khunti
EE, BCD, Building Division, Khunti
Renovation of Community Health Centre at Karra, District- Khunti.
2026_BCD_121302_1
BCD/EE, Building Div.Khunti-16/2026-27
Open Tender
Civil Works - Buildings
Works
180 days
Khunti
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.2 L
20 Nov 2026
20 Nov 2026
30 Nov 2026
20 Nov 2026
28 Nov 2026
20 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. | 679.1 | M2 | - | - |
| 2 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | 474.86 | M2 | - | - |
| 3 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. | 204.24 | M2 | - | - |
| 4 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. | 710.18 | M2 | - | - |
| 5 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. | 3,522.01 | M2 | - | - |
| 6 | Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) | 2,558.85 | M2 | - | - |
| 7 | Water proofing for Old and New Roof Slab:- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:
(a) surface preparation:-Providing and cleaning of concrete surface to remove dust, oil, grease Including removal of existing loose paint/ coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to Identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sands 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same withcement slurry including all material, labour, tools complete.
(b)1st Coat Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green 1st coat should be applied @1.50 kg/SqmU/coat. For the AND purpose of measurement the entire treated surface will be measured."
(c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface, 2nd coat should be applied @0,7 kg/ Sqmt/coat. For the purpose of measurement the entire treated surface will be measured." After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:- Sika Topseal 109hl /Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYK Aquafin TG Product Performance- Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder- Density 1.6 kg/l (mixed density) at +27°C Tensile Strength -
2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength-4 N/mm2 (According to FIP 5.15) (According to ASTM D 2370) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According To ASTM D 2370)
(d) Protection of treated surface with PCC The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1:1,5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the screed concrete (paid separately for this items). All comers shall be just leveled with the screed concrete to ensure smooth discharge VERNMES of water-the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture Insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc .For the purpose of measurement the entire treated surface will be measured." (e)Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand- Sika India Pvt.Ltd. /MYK Schomberg/Dr Per M AND Fixit/Fosroc Warranty for five years. | 1,355.4 | M2 | - | - |
| 8 | Covering of treated surface with PCC: Providing 50 mm thick Cement with aaproved quality of stone chips of 20mm to 6 mm size gradedENT OF Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2mt SCHED Mixingcement concrete in mixer with admixture of integral water prooting /SCHEDULE/and cleaned sand of F.M 2.5 to 3 including screening, shuttering, and MENT OF ND SCHED and placing in position, striking curing, taxexand royality all complete as SCHE per building specifiction and directions of E/I.Panels that has been left RNMENT SCH/ should be casted next day. There should be 6 mm gap between Panel ERNMENT S Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X GO AND 4211C, Dr.fixit Pidiproof LW + or Equivalent.AND | 1,355.4 | M2 | - | - |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 710.18 | M2 | - | - |
| 10 | Supplying and fixing new wooden fillets wherever necessary: Hollock wood fillets | 24 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
F-2-16.pdf
Tender Documents • 3.87 MB
BOQ_164110.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .