Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹30.6 L+₹28,552 (0.94%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹31.0 L+₹72,040.10 (2.38%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹31.1 L+₹82,368.90 (2.72%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹31.9 L+₹1.6 L (5.17%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
4 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS TO BLDG No. T- 25 TO T- 28A (SINGLE LIVING ACCN) AND CERTAIN REV AND MINOR WORKS AT DINJAN MIL STN UNDER GE DINJAN
2021_MES_494523_1
C/8357/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹56,000
Yes
29 Jan 2022
14 Dec 2021
6 Jan 2022
14 Dec 2021
4 Jan 2022
28 Dec 2021
60 days
Amount
Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed.
M&L for second class hardwood, scantlings, framed and fixed, wrought complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) grade Fe 290 (Gde E-165) quality -A, including distance pieces, cleats etc. complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
S&F for steel work in tubular truses including special shaped washer etc complete using ERW or inductionbut welded tubes conforming to IS 1161 - 1979 grade St-240 complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.
Dismantling weather boarding,any description, fixed in any position with nails complete all as specified and as directed.
S&F for 20 mm thick, second class hard wood boarding, clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete all as specified and as directed.
Taking down chowkats or frame, not exceedig 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
Taking down chowkats or frames, exceeding 1.5 but not exceeding 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and as directed.
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S&F for pressed steel frames for doors local work shop made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using Plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F for pressed steel frames for doors local work shop made of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using Plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
M&L for 35mm thick 2nd class hard wood plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed, Sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a).
M&L for 35 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and as directed in SSR Part I Section 8 clause 8.24 (a).
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed.
S&F for 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for 75 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
S&F for 100 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
S&F for 100 mm long, aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and as directed.
S&F for second class hardwood, small fittings such as brackets of any type, latch & hinge blocks, shaped door & window stops and the like, including all necessary labours; articles not exceeding 200 cu.cm each complete all as specified and as directed
M&L for anodised aluminium section, medium anodic coating of grade AC 15 for frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed.
M&L for anodised aluminium window and ventilator shutters, fixed type, with or without sash bar, using aluminium section weighing not less than 0.55Kg per metre including necessary joining cleats, glazing clips, rubber neoprene packing, aluminium handles 2 numbers in each shutter, hinges, anodised aluminium snap beading, screws etc complete all as specified and as directed.
S&F for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tracks, or galvanised wire staples complete all as specified and as directed.
S&F for 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
Taking down and refixing the shutters of any description exceeding 1 sqm but not exceeding 2 sqm each in the same opening complete as directed.
S&F in repairs curtain rails, harrison rail, aluminium alloy chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortor (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of chalk whiting primerfor distemper complete all as specified and as directed.
M&L for preparation of plastered surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of walls by complete removal of existing treatment including chalk whiting on wall etc and applying two coat of distemper oil emulsion over a coat of chalk whiting primer for distemper including wall care putty (minimum 1.5mm thick) complete all as specified and as directed.
M&L for preparation of plastered surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparing plastered surfaces of ceiling and applying one coats of white wash complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles of size 300mmx200mmx7-8mm thick, on vertical surfaces, including 10 mm thick backing of cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20 to 25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 15 mm thick, screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for machine cut kota stone, 20 to 25mm thick as in riser of steps, skirting, dado and pillar laidover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and 10 mm thick, screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, as in cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortar (1:6) and cutting, rounding to edge of slab, polishing complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.
M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, as in skirting, dado, etc, including 10 mm thick backing of cement mortar (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
S&F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and as directed.
M&L for 100 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and as directed.
M&L for chequered cement concrete tiles of size 25cm x 25cm x 20mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in under layer of roof treatment to provide gradient and slope and finishing the surface rough to recieve mortar complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including plaster etc, cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:4 finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming to IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm
Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 litres but not exceeding 1000 Litres complete all as specified and as directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
S&F in repairs 15 mm bore, stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs 15 mm bore, bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs vitreous china wash basin, size 550x400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No. C0406 of Parryware/Hindware/Cera.
S&F in repairs 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repairs 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F in repairs, swival shower of PTMT 15mm bore (minimum weight 40 gms) including shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (minimum wt 40 gms) complete all as specified and as directed.
S&F for Towel Rail, 600mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete 1:2:4 type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0287/0288 of Parryware/Hindware/Cera.
S&F in reapirs 10 litre capacity, PVC valve less syphonic duel type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
Dismantling of 100mm bore, PVC/cast iron or reinforced concrete /SWG drain pipes, etc with fittings jointed in cement mortar and taking out of trenches, floor or walls if required complete all as specified and as directed.
S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints laid in trenches, floor complete all as specified and as directed.
S&F for 75 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints laid in trenches, floor complete all as specified and as directed.
S&F for 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F for 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F in repairs 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) vent cowl complete all as specified and as directed.
Surface excavation averaging 15cm deep and n.exc 30cm deep and getting out including removing the same to a distance n exc 50 metre, depositing as directed as in soft/loose soil complete all as specified.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distancenot exceeding 50m and making good surface in soft/loose soil as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation of post holes filling and mass concrete, etc complete all as specified and directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, Cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in floor laid in panels/base of floor, etc, and finished the cement concrete surfaces even and fair without using extra cement making impressions of expanded metal whilst the concrete is green complete all as specified and directed.
Forming Construction joints 100mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
M&L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 75mm thick sand layer complete all as specified and as directed.
Taking down aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box (sunken type) 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
All as per item No 108 above but for one 3 pin socket outlet, 5/6 Amps on Independent board complete all as specified and directed.
All as per item No 108 above but for one 5/6 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 108 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board complete all as specified and directed.
S&F for switch piano, 5/6 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5/6 Amps, flush type bearing ISI marked complete all as specified and directed.
S&F for switch socket combination, 2 in 1, 5/6 Amps, flush type, 240 volts bearing ISI marked complete all as specified and directed.
S&F for switch socket combination, 2 in 1, 6/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and directed.
S&F for stepped type (five steps) electronic fan regulator flush type complete all as specified and directed. Make : Anchor, Model No. 14502 or equivalent.
S&F for 20 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG/Wipro.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED lamp 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj /Surya.
S&F in repairs factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and directed.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with 200 Apms rated common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing MCBs complete all as specified and as directed. Make : Cat No. DBDD04 of HPL/L&T/Havells.
S&F for MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make: Cat No. 408609 to 408617 of Legrand / Havells / L&T.
S&F for MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408587 to 408595 of Legrand / Havells / L&T.
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
S&F for 35/36 Watt LED building security light new generation energy saving and environtal friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including taking down unserviceable light fitting complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG/Wipro.
S&F in repairs for test point terminal box made of gun metal or phosphorous bronze,size 75x75x25 mm, drilled and screwed and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screwed including removing the existing old unsv one complete all as specified and as directed.
S&F in repairs sheet metal enclosure, single pole and neutral with two pin and earth plug complete with one single pole MCB, 20 Amps, 240 volts complete all as specified and as directed. Make : Havell's/L&T/Siemens/HPL/Legrand.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hardstanding using trenchless technology complete all as directed. Note: Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for galvanised iron tube light grade 40 mm bore laid in trenches/road/drain/wall alongwith all fittings complete all as specified and directed with MS clamp and nut bolts and washers etc, including taking down old GI tubing alongwith all fixing accessories complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed.
M/S HAZARIKA CONSTRUCTION
FREEZCON
M/S CHANDAN ENTERPRISE
Construction House
M/s. R. K. Trading Company
JANATA CONSTRUCTION
MAZUMDAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .