Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹2.6 CrAdmitted-Finance | ₹2.6 Cr | Admitted-Finance |
| 2 | ₹2.6 CrAdmitted-Finance | ₹2.6 Cr | Admitted-Finance |
| 3 | ₹2.9 CrAdmitted-Finance | ₹2.9 Cr | Admitted-Finance |
| 4 | ₹3.0 CrAdmitted-Finance | ₹3.0 Cr | Admitted-Finance |
| Sl No | Description | Qty | Unit | Alliance Transcon Pvt. Ltd. | Trade Linkers Associates | AJAY CONSTRUCTION | M/S CHOUDHARY ELECTRICAL WORKS |
|---|---|---|---|---|---|---|---|
| 1.00 | Schedule A | 1 | BOQ2 | 2,48,95,844 ₹2.5 Cr | 2,49,62,620 ₹2.5 Cr | 2,72,52,470 ₹2.7 Cr | 2,84,40,800 ₹2.8 Cr |
| 2.00 | Schedule B | 1 | BOQ3 | 14,26,024 ₹14.3 L | 9,71,940 ₹9.7 L | 23,42,810 ₹23.4 L | 7,50,070 ₹7.5 L |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
23 Jan 2026, 2:00 pmClosed
Executive Engineer, TLMD-IV, Jammu
Office of Executive Engineer, TLMD-IV, Jammu
Replacement of Old/ Deteriorated/ Damaged Control Cables of 220/132/33 KV Grid Station Barn.
2026_PDD_299854_1
TLMD-IV/J/15 Dated 03-01-2026 of 2025-26
Open Tender
Electrical Works
270 days
Gss Barn
As per SBD and NIT
4 documents required · 4 mandatory
₹5,000
Executive Engineer, TLMD-IV, Jammu
₹6.0 L
Office of Executive Engineer, TLMD-IV, Jammu
14 Feb 2026
3 Jan 2026
24 Jan 2026
3 Jan 2026
23 Jan 2026
3 Jan 2026
6 Jan 2026
Schedule A
Schedule B
Item Wise BoQ
BoQ_Ver3.0
Replacement of Old/ Deteriorated/ Damaged Control Cables of 220/132/33 KV Grid Station Barn.
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE OF SUPPLY (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SUPPLY OF CONTROL CABLES and M.K along with all accessories
2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
10 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
12 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
19 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
2 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 16 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
Galvanized Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self- supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Supply of 1 No Cable Fault Detector for control cables at Grid station
Item Wise BoQ
BoQ_Ver3.0
Replacement of Old/ Deteriorated/ Damaged Control Cables of 220/132/33 KV Grid Station Barn.
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE OF SUPPLY (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
ERECTION OF CONTROL CABLES, M.K , TESTING AND COMMISSIONING SAFE STORAGE, HANDLING, PRESERVATION INCLUDING FIXING OF LUGS, FERRULES, GLANDS OF VARIOUS SORTS, DISMANTLING OF EXISTING CABLES, M.K THEIR PACKING AND CARRIAGE TO THE DIVISIONAL STORE
2 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
5 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
8 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete of reputed make
10 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
12 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
16 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
19 Core, 2.5 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
2 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 6 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
4 Core, 16 sq mm, 1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete
Erection of Galvanized Marshalling kiosk its earthing and termination complete in all respect
Construction/Repairing of 220/132 cable ducts main as well as sub main
Dismantling of existing 1100 V, PVC insulated, PVC sheathed, FRLS, copper conductor control cable of various cores such as 2/5/8/12/16 2.5 sqmm complete in all respect and carriage thereof back to divisional store.
Dismantling of existing M.K Box complete in all respect and carriage thereof back to divisional store.
Construction/Repairing of cable trays
Construction of cable duct covers
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
SBD.pdf
Tender Documents • 0.39 MB
STR.pdf
Tender Documents • 0.30 MB
scope.pdf
Tender Documents • 0.28 MB
BOQ_972795.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid