Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.0 L+₹1.2 L (4.02%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹37.6 L+₹7.8 L (26.3%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹38.6 L+₹8.8 L (29.7%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹38.8 L+₹9.0 L (30.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
13 May 2024, 6:00 pmClosed
GE I R AND D EAST BANGALORE 93
GE I R AND D EAST BANGALORE 93
REPAIR REPLACEMENT OF UNSERVICEABLE SUBMAIN WIRING POINT WIRING SWITCHES SOCKETS AND EARTHINGS FOR BUILDING UNSERVICEABLE DISTRIBUTION BOARDS INDUSTRIAL SOCKETS CEILINGS EXHAUST FAN INCLUDING ALLIED WORKS AT VARIOUS LOCATIONS AT GE OFFICE COMPLEX
2024_MES_650796_1
8477/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D EAST BANGALORE 93
please refer tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D EAST BANGALORE 93
₹96,000
Yes
8 Jun 2024
23 Apr 2024
21 May 2024
23 Apr 2024
13 May 2024
7 May 2024
24 Apr 2024 - 4 May 2024
Amount
Supply and fix Point wiring complete with multi stranded copper conductor cable of size 1.5 sq.mm (for phase and neutral ) PVC insulated, unsheathed, FRLS cable, 1100 volts grade conforming to IS 694 multistranded, drawn through in and including rigid PVC surface type conduit / casing capping on walls/ floors/ ceiling etc with and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sq.mm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, including cutting chases to the walls / floors/ ceiling and repairing the surfaces to match with the existing finish after work, complete all as specified and as directed for one light/ fan/exhaust fan point controlled by one way switch. NOTE:- Quoted rate deemed to be Included the taking down carefully un serviceable aluminium/ copper point wiring (light, fan, socket or power) complete with accessories for reuse/ offering under sch of credit and making good the disturbed surface as the existing one, complete all as specified and directed.
All as per Sl Item No.1 above but one light point controlled by 02 two way switches complete all as specified and as directed.
All as per Sl Item No.1 above but one three pin socket outlet 6 Amps socket on the same board with other switches complete all as specified and as directed.
All as per Sl Item No.1 above but one 3 pin socket point 5 Amps on the independent board complete all as specified and as directed.
All as per Sl Item No.1 above but one bell point controlled by one bell push complete all as specified and as directed.
Supply and fix for point wiring complete with multi stranded copper conductor cable of size 1.5 sq.mm PVC insulated, unsheathed, FRLS cable , 1100 volts grade conforming to IS 694 multistranded , drawn through in and including rigid PVC type conduit concealed in walls / floors/ ceiling etc and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sq.mm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chassis to the wall s/ floors/ ceiling and repairing with existing surface after work ,complete all as specified and as directed for One light/ fan/exhaust fan point controlled by one way switch. Note:- Including taking down carefully U/S aluminium/ copper point wiring (light, fan, socket or power) complete with accessories removing all material for reuse/ issued under sch of credit and making good the disturbed surface as the existing one, complete all as specified and directed.
All as per Sl Item No 1 here-in-before but using copper conductor 2.5 sqmm PVC insulated unsheathed FRLS cable with copper conductor size 2.5 sqmm PVC insulated unsheathed continuous earth continuity for 3 pin 15 amps socket outlet independently all as specified and as directed. NOTE:- Quoted rate deemed to be Included the taking down down carefully un serviceable aluminium/ copper power point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc , removing all material for reuse/offering under sch of credit and making good the disturbed surface to match with the existing finish, complete all as specified and directed.
Supply and fix in replacement switch modular type single pole 1 way 6 Amps 230 volt complete all as specified and directed.
Supply and fix in replacement switch modular type single pole 2 way 6 Amp 230 volt complete all as specified and directed.
Supply and fix in replacement Socket Modular type 6A 2-3pin combined 2 module 230Volts grade all as specified and directed.
Supply and fix in replacement switch modular type 1 way 16A, 1 module all as specified and directed.
Supply and fix in replacement Socket Modular type 6A/16A 2-3pin combined 2 module 230Volts grade all as specified and directed.
Supply and fix in replacement Modular switch bell push 6 Amps one module all as specified and directed.
Supply and fix in replacement modular type fan regulator 120 W two module complete all as specified and directed.
Supply and fix in replacement bell AC 230V single phase all as specified and directed.
Supply and fix in replacement for ceiling rose surface bakelite two to three terminal complete all as directed.
Supply and fix in replacement for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
Supplying and fixing in replacement for LED batten with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver1 x 20 watts fixing on wall/ celling with down rod of suitable length complete all as specified as directed.
Supply and fixing in replacement for 10 Watt LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing in replacement for round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling of any height/location including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. NOTE:- 1. All necessary fixing/connecting arrangements to be provided by the contractor without any extra cost to Govt.. 2. Quoted rate is to be deemed to included the charges of necessary boom fit.
Supply and fixing in replacement for LED luminaires square type 2' x 2' 36 Watt with Environmental friendly new generation aesthetical designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstong / gypsum or similar ceiling mounting system including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed. NOTE :- 1. All necessary fixing/connecting arrangements to be provided by the contractor without any extra cost to Govt. 2. Quoted rate is deemed to be included the charges of necessary boom fit.
Supply and fix in replacement LED high bay light fittings 150W, IP66 very high efficiency round high bay in PDC housing suitable for industrial application. The luminaire has efficacy upto 150Lm/W to reduce quantity/wattage thereby reducing operational cost complete all as specified and directed. NOTE :- 1. All necessary fixing/connecting arrangements to be provided by the contractor without any extra cost to Govt. 2. Quoted rate is deemed to be included the charges of necessary boom fit.
Dismantling the ceiling fan complete of any type and size, cleaning, servicing, greasing to bearings checking of nuts, bolts , safety split pin, bushes , capacitor and complete one coat of spray painting with Duco paint or equivalent including writing of fan No with apporved stencils as directed by Engr-in- charge testing and refixing all as specified and directed. Note :- Expendable stores like cotton waste/cleaning materials, grease, lubricants, machine screws, safety split pin, bolts/nuts and transportation to and from site to work place are deemed to be included in rate quoted.
Dismantling all components of ceiling fan 1200mm sweep, cutting and removing burnt out copper winding from the rotor assy and rewinding with super enamelled copper winding wire of suitable gauge and turns with necessary insulation materials, varnishing, reassembling, greasing to bearing, replacing bushes, replacement of capacitor and complete testing all as specified and directed. Note:- (a) The spares like ball bearing, capacitor and GM bush required for repair the ceiling fan will be measured and paid separately under respective items of BoQ. (b) Expendable stores like cotton waste /cleaning materials, grease, lubricants, machine screws, safety split pin, bolts, nuts and transportation to and fro from site to work place are deemed to be included in rate quoted.
All as per Sl Item No.24 here in before but for 1400mm sweep ceiling fan all as specified and directed.
All as per Sl Item No.24 here in before but for upto 300mm sweep exhaust fan all as specified and directed.
All as per Sl Item No.24 here in before but for 300 mm to 450mm sweep exhaust fan all as specified and directed.
All as per Sl Item No.24 here in before but for 400 mm to 450mm sweep wall mounted fan all as specified and directed.
All as per Sl Item No.24 here in before but for 400 mm to 450mm sweep pedestal fan all as specified and directed.
Supply only fan bearings suitable for ceiling fan /exhaust fan of the existing size of superior quality complete all as specified and directed
Supply and fix in replacement of capacitor 2.5mfd suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed
Supply and fix in replacement of capacitor 4.0mfd suitable for exhaust fan complete all as specified and directed
Material and labour for one coat of painting the exhaust fan along with down rod and blades using spray gun with existing colour with Duco paint or equivalent at the site including dismantling the fan from the hook and refixing complete all as specified and as directed.
Supply and fix in replacement for sub main wiring complete with 2 runs of 4 sq.mm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor confirming to IS-649, 1100 volts grade with colour code and drawn through and including 25mm dia PVC non metallic rigid conduits and conduit accessories run on surface of wall / floors / ceiling etc and connecting terminal ends including 1x 4 sq.mm PVC insulated unsheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth complete all as directed and specified. Note: (i) Two runs of 4.0 sq.mm copper cable, one run of earth wire of 4 sq.mm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM. (ii) Quoted rate is deemed to be Included the taking down carefully un serviceable aluminium/ copper wiring complete, removing all material for reuse/ offerirng under sch of credit and making good the disturbed surface to match with the existing one, complete all as directed.
Supply and fix in replacement for sub main wiring complete with 2 runs of 6 sq.mm PVC Insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including concealed 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 1x6 sq.mm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: (i) Two runs of 6.0 sq.mm copper cable, one run of earth wire of 6.0 sq.mm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM. (ii) Quoted rate is deemed to be Included the taking down carefully un serviceable aluminium/ copper wiring complete, removing all material for reuse/ offerirng under sch of credit and making good the disturbed surface to match with the existing one, complete all as directed.
Supply and fix in replacement for sub main wiring complete with 4 runs of 10 sq.mm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 1x10 sq.mm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: (i) Four runs of 10 sq.mm copper cable, one runs 10 sq.mm earth wire and 25mm dia PVC conduit shall be measured and paid as one RM. (ii) Quoted rate is deemed to be Included the taking down carefully U/S aluminium/ copper wiring complete, removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
Supply and fix in replacement for sub main wiring complete with 2 runs of 2.5 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 1x2.5 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: (i) Two runs of 2.5Sqmm copper cable, One runs 2.5 Sqmm earth wire and 25mm dia PVC conduit shall be measured and paid as one RM. (ii) Quoted rate is deemed to be Included the taking down carefully U/S aluminium/ copper wiring complete, removing all material for reuse/ issued under sch of credit and making good the disturbed surface as the existing one, complete all as directed.
Supply and fix in replacement of MCB DB SPN 4 way DB double door type single phase 230 Volts complete including dismantling the old one all as specified and directed. Note :- Including Taking down carefully U/S DB's complete, removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
All as per Sl Item No -38 here in before but of 8 Way 230 Volt all as specified and directed.
All as per Sl Item No - 38 here in before but of 12 Way 230 Volt all as specified and directed.
Supply and fix in replacement of MCB DB TPN 4 way DB double door type single phase 415 Volts complete including dismantling the old one all as specified and directed. Note :-Quoted rate is deemed to be Included the taking down carefully U/S DB's complete, removing all material for reuse/ issued under sch of credit and making good the distrubed surface as the existing one, complete all as directed.
All as per Sl Item No- 41 above but of 6 Way DB double door all as specified and directed.
Supply and fix in replacement for Single pole and neutral enclosure with a two pin and earth plug and socket plug and socket complete with one MCB single pole of 20 Amps, 240V all as specified and directed.
Supply and fix in replacement of MCB SPN 32Amps 230 Volts C curve single phase including dismantling the old one all as specified and directed.
All as per Sl Item No 44 above but MCB SPN 40 to 63 Amps 240 Volt complete all as specified and directed
Supply and fix in replacement of MCB SP 5-32Amps 230 Volts single phase including dismantling the old one all as specified and directed.
Supply and fix in replacement of MCB TPN 40-100 Amps 415 Volts three phase including dismantling the old one all as specified and directed.
Supply and fix in replacement of MCB TPN 16-32Amps 415 Volts three phase including dismantling the old one all as specified and directed.
Supply and fix in replacement of MCB TP 25-63 Amps 415 Volts three phase including dismantling the old one all as specified and directed.
Supply and fixing LED building security light 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including 1.5 Mtr length GI tubing medium grade 25mm dia bent to shape with necessary CI clamps, bolts etc for fixing and connecting from ceiling rose to filling with 3 core 1.5 sq.mm insulated copper cable complete all as specified and directed.
Earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm galvanised iron strip complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire 4mm dia above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
Supply and fix for complete repair of the Earth pit cover, funnel, bolts & nuts, GI pipe, Salt and charchol complete set as per requirements. Chamber cover should be marked as Earth pit. All the Lift earth pit value to be measured and report to be submitted to the office for record all as directed and specified. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre. 2. Rates are included the repair/marking and testing complete. 3. If new earthing GI wire 4mm dia/Strip required will be measured and paid seperately. 4. Earth resistance not exceeding 1.0 ohm.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specifed and directed. Note : 1. All necessary fixing/connecting arrangements of nuts, bolt, MS rod to be provided by the contractor without any extra payment from department. 2. Quoted rate is to be deemed the charges of necessary boom fit.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
All as per Sl Item No- 57 above but of cap 40 W complete all as specified and directed
Supplying of LED tube rod of 20W suitable for fixing of fluorescent tube light fittings of 36/40W all as specified and directed.
Supplying of LED 4 pin type rod of 18W suitable for fixing of fluorescent light fittings of 36W all as specified and directed.
Supply and fix for disconnecting burnt LT Cable from MCCB /Main Switch etc and cleaning the bus bar and removing carbon and rusted nut bolts etc complete and reconnecting the LT Cable after replacement of aluminium lugs, glands etc for the 10 sqmm to 35 sqmm 3.5 core as per direction of Engr-in- Charge.
RRK PROJECTS
Lucky Enterprises
M/S Sneha Enterprises
Vishwas Enterprises
GKR and CO
ABHISHEK CONSTRUCTIONS
Meghana and Gowda Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .