Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC | ₹1.0 Cr | 1 | Accepted-AOC DUE TO LOWER SIDE OF RATES |
| 2 | 2₹1.1 Cr+₹7.0 L (6.85%)Rejected-AOC | ₹1.1 Cr+₹7.0 L (6.85%) | 2 | Rejected-AOC DUE TO HIGHER SIDE OF RATES |
| 3 | 3₹1.1 Cr+₹10.1 L (9.87%)Rejected-AOC | ₹1.1 Cr+₹10.1 L (9.87%) | 3 | Rejected-AOC DUE TO HIGHER SIDE OF RATES |
| 4 | 4₹1.2 Cr+₹17.3 L (16.9%)Rejected-AOC VPO DAULATPUR DISTT HISAR 125122 | DAULATPUR | HISAR | HARYANA | 125122 | ₹1.2 Cr+₹17.3 L (16.9%) | 4 | Rejected-AOC DUE TO HIGHER SIDE OF RATES |
| 5 | 5₹1.3 Cr+₹23.7 L (23.1%)Rejected-AOC | ₹1.3 Cr+₹23.7 L (23.1%) | 5 | Rejected-AOC DUE TO HIGHER SIDE OF RATES |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
29 Apr 2020, 2:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PUBLIC HEALTH ENGINEERING DIVISION NO. 2, HISAR
Providing Raw Water arrangements by pumping for four No WW village Niyana Kharar Alipur Kulana and Mayyar from Balsamand Branch at RD 42800L Distt Hisar Const of 450mm id RCC pipe channel RCC SS Tank, RCC Sump RCC Pump Chamber Installation of Pumpi
2020_HRY_125887_1
113965 Dated 14.11.2019
Open Limited
Civil Works - Buildings
Works
180 days
HISAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
EXECUTIVE ENGINEER
₹2.1 L
Yes
17 Jun 2020
8 Apr 2020
29 Apr 2020
8 Apr 2020
29 Apr 2020
8 Apr 2020
Amount
Supply & Erection of Horizontal spindle split casing type pumping sets of minimum Four (4) Star rating duties directly coupled to AC squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. A) Raw water pump set 6000 Lpm , 50 mtr head
Supply and fixing following CI D/F pipe and specials/ bell mouth/ including cost of joining materials, laying, jointing, refilling including making adequate support of masonry/concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the Department as per plan shown from the foundatiion wall of pump chamber for all the raw water and clear water pumping sets at water works in position, as per specification given in schedule No.II For Pumping Machinery A) Detail of pipe and specials a) CI D/F bends, Reducers, tees , tappers, tail piece blank flange etc
B) CI D/F pipes ii. 250mm i/d for delivery
iii. 300mm i/d for suction
c) Bell Mouth c) 250mm i/d
Supply, erection, testing and commissioning of Wall mounted electrical panel board , fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900mm having following items : a) For Raw water pump sets for 6000 Lpm x 50 M head = 2 No. a) Main switch 165 Amp 2 No.(L&T, Siemens, ABB) b) Volt meter 100 x 100mm range 0 to 1000 volt 1 No.(AE/KAPPA/L&T) c) Amp meter 100x100mm range 0 to 250 Amp 2 Nos(AE/KAPPA/L&T) d) CT 250/5 3 Nos (AE/KAPPA/L&T) e) VSS 1 No. & ASS 2 No. of approved make f) SPP 2 No. of approved make g) Motor starter, star delta, 2 No. for 6000 LPM x 50 M Head Motor (L&T Siemens, AAB) h) Capacetor of suitable capacity = 2 No i) Indicating Lamp-One set j) Change over switch 165 Amp = 1 No
Supply erection, testing of ISI marked Aluminium wire for 2 Nos motors with under ground system in PVC and flexible pipes copper wire size 2 x 70 sq Sq mm complete in all respects with accessories like thimble etc.
Supply erection, testing of ISI marked Aluminium wire for 1 No panel boards from mainswitch to panel and wiring of panel with size 120 sq mm (Aluminium wire) ISI marked complete in all respects with accessories like thimble etc. complete in all respect
Supply ,erection, testing of light fittings including wire in the Pump Chamber with material upto 10 points including switch, button, plug, PVC conduit pipe & copper wire etc. as per approved specifications complete in respects.
Providing and fixing exhaust fans 18" i/d (450 mm) complete with suitable G.I. sheet of approved make compete in respects.
Providing and fixing ceiling fan 1400 mm (56") with speed adjuster of reputed make compelte ( make Crompton, Usha, Bajaj, Orient) comp-lete in respect
Supply, erection, testing, of reputed make CFL Vapour light 100 watts with fitting and accessories complete in respect
Supply, erection, testing & commissioning of standard make 160 KVA 11/0.433 KVA 3 phase 50 cycle copper wound outdoor type transformer with annual tape charge and termination complete in all respect as per details in DNIT (Kirloskar / ABB/ GE make)
Supply, erection, testing & commissioning of 3 HP electric driven dewatering pumping set capacity 5m3 per hour 15 meter total head with wiring starter, switches and G.I. pipes and specials canvas hose and accessories as per specification in schedule No. II etc. complete in all respects.
Distribution System A) DI Plain Ended Tees, Bends, Reducers etc. for distribution system
Supply, erection, testing and commissioning of 200 KVA Diesel generating set noise control acoustic enclosure radiator cooled 3 phase, 4 wire , 50 cycles 415 + (-) volts AC alternator coupled directly through a set of flexible coup;ong on a common MS fabricated base frame with diesel engine complete as per approved NIT. The rating should be at 1500 RPM a) Diesel Engine c) Alternator c) Base Plate d) Battery 24 V e) 1x120 sq mm 3.0 core XLPE Aluminium = 20 mtr f) Tools AMF Panel a) Motorized change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp b) Under voltage/over voltage relay = 2 No 415 VAC c) Engine starter relay 24 VDC 1 No d) Electronic Timer 24 VDC 1 No. e) Electronic Timer 24 VAC 2 No f) Auxiliary relay 220 VAC 2 No g) Auxiliary relay 220 VAC 3 No h) Metering set 415 VAC 1 set (Amp meter, volt meter, ASS, VSS, Phase indicators, control fuse, frequenecy meter CT's) i) Metering set 24 VDC (Amp motor, volt meter) j) Over load protection for DC 1 No k) Battery charger 24 VDC (Blueron Make) l) Copper bus bar of suitable size m) KWH meter 96 square mm size n) Starting fuse botton and key switch (on/off) o) Engine protection unit with audio visual alarm and shut down for low lubricating oil pressure and high coolent temperature p) Indicating lamp for low lubricating oil pressure high coolant temperature, set running, loan on , DC control on. Note :- Control panel shall have the provision to provide auto manual failure panel (AMFP)
Operatiion & Maintenance of water works (disinfection material supplied by the PHED) as per schedule IV for a period of 5 years ( 60 months) after three months of trial run (will be charged to the A/Mtc.Estimate) i) Operatiion & Maintenance during the defect liability period (Operatiion only)
Ist year Operatiion & Maintenance after defect liability period
2nd year Operatiion & Maintenance
3rd year Operatiion & Maintenance
4th year Operatiion & Maintenance
Bidder Name
Amount
RAM PHAL SINGH CONT
NASEEB SINGH CONTRACTOR
Subham Construction Company
JAI SINGH CONTRACTOR
THE GARHI ADARSH COOP L AND C SOCIETY LIMITED
Subham Construction Company
THE GARHI ADARSH COOP L AND C SOCIETY LIMITED
NASEEB SINGH CONTRACTOR
RAM PHAL SINGH CONT
THE GARHI ADARSH COOP L AND C SOCIETY LIMITED
JAI SINGH CONTRACTOR
NASEEB SINGH CONTRACTOR
RAM PHAL SINGH CONT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .