Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.4 L+₹3.9 L (14.9%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L2 | Rejected-Finance Being L2 |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
10 Nov 2021, 6:00 pmClosed
GE (MIS) MHOW
GARRISON ENGINEER (MAINT) INF SCHOOL MHOW
SPL REPAIR TO TOILET BLOCK OF BUILDING NO DL 28 AT PW DIV INF SCHOOL UNDER GE MIS MHOW
2021_MES_481177_1
8422/GE (MIS) /Mhow
Open Tender
Civil Works
Item Rate
180 days
GE (MIS) MHOW
as per tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) MHOW
₹61,000
Yes
26 Nov 2021
12 Oct 2021
12 Nov 2021
12 Oct 2021
10 Nov 2021
26 Oct 2021
Amount
Demolition of cement concrete n.exc 15 cm depth of any description and in any position not otherwise specifically provided (below or above ground level) including removal of concrete debris from site up to 500 metre all as specified and directed.
Demolition of cement concrete exc 15 cm depth of any description and in any position not otherwise specifically provided (above ground level) including removal of concrete debris from site up to 500 metre all as specified and directed.
Taking down old tarfelt of existing water proofing treatment on RCC roof surface including roughening surface of old concrete floor by picking,sweepeing, cleaning, and washing etc. and removing at low laying area complete all as specified and directed.
M&L for PCC 1 : 1.5 : 3 type A0 using 12.5mm graded stone aggregate laid on sunken floor surfaces of existing RCC slab ,average thickness 50mm, laid in slope mixed with integral water proofing compound manufactured by Dr FIXIT LW+ @ 200 ml/bag of cement or other equivalent as approved by GE , finish the surface even & smooth without using extra cement as in repair to sunken portion treatment all as specified and directed. (Note : Liquid water proofing compound shall be measured and paid seperately under relevent item).
M&L for rendering 15mm thick in CM 1:3 mixed with liquid water proofing compound as per manufactured instruction and finished the surface even and smooth without using extra cement as in sunken floor surfaces and vertical surface of RCC slab, complete all as specified and directed. (Make:- Dr FIXIT LW+ @ 200ml per Bag of cement (Note : Liquid water proofing compound shall be measured and paid seperately under relevent item).
M&L for applying water proofing chemical treatment to sunken floor and vertical surface of RCC slab by applying a base coat of Dr FIXIT Fast Flex chemical of thickness between 1 to 1.5 mm.
M&L for preparation of surfaces for applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete.
M&L for applying a tack coat of industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces complete all as specified .NOTE: (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat shall be measured and paid separately under this item .)
M&L 3mm thick APP based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.Note: Application of APP membrane shall be carried out through authorised applicator of Manufacturer.
M&L for provide PVC (SWR) spout pipe of 40mm bore & 60cm length in sunken floor including cutting holes in brick walls built in cement mortor and making good the dismantled portion with PCC (1:2:4), type B1 using 20mm graded stone aggregate and finished the disturbed surface to match with existing finish complete all as specified and as directed .
M&L for cutting holes in brick walls built in cement mortor at the starting point of down take soil/waste pipe at any floor, fill the joints with thick mortor in CM 1:3 and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate and finished the disturbed surface to match with existing finish complete all as specified and as directed .
M&L for PCC 1:5:10 type E2 (using 40mm graded brick aggregate) as in filling of sunken portion complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregate , as in bases of floors complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in bases of floors complete all as specified and directed.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete as directed and specified.
M&L for PCC 1:2:4 Type B1 using 20mm graded stone aggregate in roof kerbs or mud stops, benching, rounded or chamfered on edges complete as directed and specified.
M&L Non skid ceramic joint free (coloured tiles) 7 to 8 mm thick square/rectangular area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile and including screed bed 15 mm thick in cement mortar 1:6 complete all as directed and specified.
M&L for 75 mm thick PCC 1:3:6 type C2 using 20mm graded stone aggregate as in plinth protection finished the surfaces of concrete topping even and fair (without using extra cement) including making joint at every 3 metre interval and at corner and filled with mixture of bitumen and sand , laid in alternate bays complete all as specified and directed.
Demolition of brick work built in cement mortar in any position including all quoins, arches & pillars etc. complete all as directed and specified.
M&L for Brickwork with fly ash brick with using modular size brick , straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as directed and specified.
M&L for Brickwork with flyash bricks with using Modular size Brick, straight or curved on plan to any radius in half brick thick walls, built in CM 1:6 complete all as directed and specified.
M&L for RCC 1:2:4 type B1 using 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for formwork to soffits of flat suspended slabs such as roof slabs, floor slabs, landings and similar work; not exc 200mm thick (Horizontal or sloping)
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.
Taking up or down steel water tubing and connection 15 mm bore in pipe including cleaning for re-fixing or removel to store complete all as specified and directed.
All as per item No 25 above but 20 mm bore.
All as per item No 25 above but 25 mm bore.
S&F in repair steel water tubing 15mm bore, medium grade, galvanised, with all fittings and fixed complete in walls and ceilings or laid in floor complete all as specified and directed.
All as per item No 28 above but 20 mm bore.
All as per item No 28 above but 25 mm bore.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) removing serviceable tiles to stores and rubbish off premises complete all as directed and specified.
M&L Glazed ceramic Coloured tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15mm thick rendering of CM 1:4 all as directed and specified.
M&L for granite slabs 20mm thick machine cut, bedded laid over and including cement screed 15 mm thick in CM (1:4) laid and jointed with grey cement slurry , mixed with pigment to match with the shade of slab including grinding,moulding rounding, chamfaring and polishing complete all as specified & directed.
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key scrubbing down with water etc complete all as directed and specified.
M&L for rendering 5mm thick ,on concrete surfaces in cement mortar 1:3 finished on even and smooth without using extra cement on RCC chajja,beam, column and height of building 3 metre to 10 metre ) complete all as specified & directed.
M&L for rendering 15 mm thick in cement mortar 1:4 , mixed with water proofing compound, on brick or concrete fair surfaces, finished even and smooth without using extra cement mixed with liqued water proofing compound Dr FIXIT LW+ @ 200 ml/bag of cement or other equivalent as approved by GE complete all as directed and specified. NOTE: WPC shall be measured and paid separetely under relevant item .
M&L for rendering 15 mm thick in CM 1:6 finished even and smooth without using extra cement etc complete all as directed and specified.
M&L rendering 10mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement etc complete all as directed and specified.
Supply only liquid water proofing compound.
M&L preparation of new plastered surfaces of ceiling and applying three coat of white wash all as directed and specified.
M&L for preparation of old/new plastered surface of wall and applying 2mm thick white cement base wall care putty in two coats (each coat not less than 1mm) over a coat of cement base primer on walls and surface finished even and smooth with sand paper complete all as specified and directed
M&L Preperation of newly plastered wall surfaces and applying two coat of oil bound distempering over a coat of cement primer finished even and smooth complete all as directed and specified.
M&L for preparation of old decorated surfaces of wall including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying two coats of first quality exterior weather proof water base emulsion paint over a coat of primer of same make all as specified and directed. Make: Asian-Apex / Berger- Weather antidust / Nerolac-Excel / Dulux-Weathershield)
S & F in repairs PVC (SWR) Floor trap / Nahani trap plain or multi with stainless steel grating including jointing to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S&F in repairs 15 mm dia Stop cock cast copper alloy fancy type CP with long shank and cup (concealed type) , screw down high pressure, screwed both ends for iron pipe or for union and fixed complete all as directed and specified.
S&F in repairs Angle Stop valves one way, brass chromium plated, , fixed to iron pipe or for unions 15mm bore complete all as directed and specified. Make : Jaquar.
S&F in repair pillar taps (swan neck fancy type) cast copper alloy with capstan head, screwed down ,high pressure with long screwed shanks and fly nuts fixed with 15 mm bore pipes complete all as specified and directed.
S&F in repairs bib taps fancy type cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as directed and specified.
S&F Brass chromium plated shower rose fancy type 125mm size with swivel joints, fixed in repairs complete all as directed and specified.
S&F in repairs PVC low level flushing cistern of 10 litres capicity fixed to wall with bracket including PVC flush pipe 32 mm bore (ISI Marked) complete all as specified and directed.
S&F in repair mild steel chromium plated grating doom 100mm dia with or without waste hole complete all as directed and specified.
S & F in repair vitreous China wash basin white (Oval shaped under counter) of size 550 mmx400 mm including 32 mm brass CP waste coupling and including 45cm long PVC connection with PTMT nut at both ends, pipe complete all as specified and directed.
S&F in repair Vitreous china squatting pan of Orissa patten of size 580mm x 440mm white with P trap and integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 all as directed and specified.
S&F in repairs PVC connection 15mm bore of pipe with brass nut size 450mm long complete all as specified and directed.
S&F in repair Vitreous China uninal bowl, half stall coloured, with CP urinal spreader for fixing with 15 mm dia pipe, union for discharge pipe, PVC waste pipe 32mm bore, providing and fixing plugs, bedding urinals against the wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long steel screws, pointing around the urinal back in cement, complete all as specified and directed.
S&F in repair Waste coupling of 40 mm dia PTMT (half or full threaded) . (Minimum weight 60 gms) complete all as specified and directed.
S&F PVC waste pipe fixed to any type of coupling of 40mm threaded complete all as specified and directed.
S&F in repair Brass chromium plated CP tubular towel rail 20mm dia
S&F Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long fixed in repairs complete all as directed and specified.
S&F in repair Rotational moulded polyethylene water storage tanks Capacity 2000 litre (cylindrical vertical with closed top) hoisted and including 25 mm bore PTMT Nipple and ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass suitable for HDPE water tank. (Minimum weight 25mm- 65gms) including dismantling of old water tanks and removing to store complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks Capacity 1000 litre (cylindrical vertical with closed top) hoisted and including 25 mm bore PTMT Nipple and ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass suitable for HDPE water tank. (Minimum 25mm- 65gms) including dismantling of old water tanks and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm each removing to or from store including cutting holes and making good the disturbed portion of hold fast portion complete as directed and specified.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm removing to or from store including cutting holes and making good the disturbed portion of hold fast portion complete as directed and specified.
S&F factory made solid panel both side prelaminated PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joining together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S&F Solid PVC both side prelaminated door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawings including all fixtures shown on drawings.
S&F pressed steel frames for doors with one with one or more rebates size of frame (105 x 60 mm ) including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as directed and specified.
S&F second class hard wood plain, framed, panelled factory made shutters approved quality 35mm thick (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per I.S.1003 (Part-I) kiln seasoned and chemically pressure treated, fixed with screws etc. complete all as directed and specified.
S&F Butt hinges,cold rolled mild steel and fixed, 100mm size complete all as directed and specified.
S&F Butt Hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, 100mm size complete all as directed and specified.
S&F Extruded aluminium alloy handles fabricated type anodised 200mm size complete all as directed and specified.
S&F 150mm long aluminum anodised barrel tower bolt of extended section complete all as directed and specified.
S&F 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed in repair complete as directed and specified.
S&F in repairs of Mild steel rat tail rod pattern helical door spring of size 300mm including roller and roller plate fixing to iron frame by welding including cutting out old damaged/inactive helical door spring complete all as specified and directed.
S&F Powder coated anodised aluminium window and ventilator shutters, sliding three track type (02x Glass & 01xWiremesh Shutter) type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and roller with aluminium grill of suitable size Channel for fixing etc. complete all as specified (minimum thickness of powder coating 50 micron) complete all as specified and directed.
S&F Powder coated anodised aluminium ventilator (Louvers type) with louvers glass and glass stay, section weighing 0.55 kg/m including necessary joining cleats, glazing clips for fixing of wiremesh, rubber neoprene packing, anodised aluminum snap beading screws etc.(minimum thickness of powder coating 50 micron) complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, screws and nuts botls etc. complete all as specified and directed.
M&L for preparing new wood surface and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L Preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint.over a coat of red oxiedprimer complete all as specified and directed.
M&L for forming 20mm thick Expansion joints filled with pre-formed bituminous filler for depth of 150mm thick slab and top 30mm primed and sealed with sealing compound, Grade ‘A’
S&F 1mm thick Plain, galvanised, mild steel sheeting drilling and fixing with necessary screw, in construction joint, etc (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st-240 including one shop coat of zink chromate primer paint including preparation of surface
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L for Point wiring in repairs with FR LS PVC insulated PVC unsheathed electric cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area drawn in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good and matching disturbed surface of wall with existing surface of wall (cutting except on ceiling for fan point only, on ceiling instead of PVC conduit surface casing caping will be used) & 1.5 sqmm green FR LS PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including galvanised boxes and bakelite sheet for mounting switches, sockets, fan regulators etc for One light point/fan point controlled by one switch . Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/Kalinga/Jindal/Asian .
One light point controlled by one switch
One Exhaust fan point controlled by one switch
One 5amps socket out let point controlled by one switch on same board with other switches.
One 5amps socket out let point on independent board controlled by one switch.
All as per item no 92 here in before but using PVC insulated unsheathed 2.5 sqmm cross sectional area cable for phase /neutral & for earth 2.5 Sq mm green PVC insulated cable for 15 amps socket point on independent board controlled by one switch.
S&F in repair switch piano flush button single pole one way 6 Amp 240 volt complete as directed.
S&F in repair socket outlet flush type 5 pin, 6 amps, 230 volts complete all as directed.
S&F in repair switch piano flush button single pole one way 15 Amp 240 volt complete as directed.
S&F in repair socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 230 volts complete as directed.
S&F in repair ceiling rose surface bakelite three terminal complete all as directed.
S&F in repairs integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. Make:- Havells Cat No. LHEXBLP7PN1W018 , Bajaj cat Pt No. BCLSB 18WH or other equivalent in Wipro
S&F in repairs integrated LED tube light fitting 1x9/10 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square box including taking down the existing complete all as specified and directed .Make:- Havells Cat No. LHEXBLP7IN1W009 Bajaj Cat Pt No. BCLSB 10 WH or other equivalent in Wipro
S&F in repairs LED street light fittings 1x30 Watt, 5700K complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 65 protection fixed on and including sufficient length and appropriate size GI bracket with all accessories duly connection with three core flexible copper cable complete all as specified and directed .Make:- Havells Cat No.LHEXAYP7PN6K030 Crompton Cat No. LSTO-25-CDL, Bajaj Cat No. BCLST 25W LED IV2
S&F in repair double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral complete all as specified and directed by Engr-in-Charge.
S&F in repair MCB SPN 6 to 32 amps 10 KA, 'B' series including connection with suitable size aluminium / copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium / copper lugs including taking down the existing complete all as specified and directed by Engr-in-Charge.
S&F in repair sub main wiring with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FR LS PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge.
S&F Exhaust fan 200mm sweep, AC single phase 230 Volts, non metallic type, complete with louver including electric connection with suitable size copper conductor cable, clamps, nuts, bolts etc including making hole of appropriate size in the existing brick wall and making good the disturbed wall and matching with the existing surface of wall complete all as specified and directed by Engr-in-Charge. Make : Havells Model: Ventil Air-DX white or equivalent in /Bajaj/Crompton
sunway associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .