Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC KAGZI MOHALLA DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | ₹44.6 L Quoted ₹44.9 L | L1 | Accepted-AOC AWARD |
| 2 | L2₹47.0 L+₹2.0 L (4.48%)Rejected-Finance 1ST FLOOR 100 FT ROAD NEAR HERO HONDA AGENCY OPP NARANG CHILDREN HOSPITAL BIBIWALA ROAD NORTH ESTATE | ₹47.0 L+₹2.0 L (4.48%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹47.4 L+₹2.5 L (5.54%)Rejected-Finance | ₹47.4 L+₹2.5 L (5.54%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹48.1 L+₹3.2 L (7.04%)Rejected-Finance VILL PO MANOHAR CHHAPRA MOTIPUR DISTT MUZAFFARPUR PIN 843111 | MOTIPUR | MUZAFFARPUR | BIHAR | 843111 | ₹48.1 L+₹3.2 L (7.04%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹48.8 L+₹3.9 L (8.61%)Rejected-Finance 13 CEMENTRY ROAD DANAPUR CANTT PATNA BIHAR | PATNA | PATNA | BIHAR | 801503 | ₹48.8 L+₹3.9 L (8.61%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹41.4 L
EMD Value
₹82,700
Closing Date
3 Feb 2024, 6:00 pmClosed
GE
GARRISON ENGINEER DANAPUR CANTT PIN 801503
PROVISION OF PARKING SHED NEAR BLDG NO EW5 SPECIAL REPAIR TO ROOFING FALSE CEILING AND FLOORING/PLASTERING WORK AND ELECTRIC REWIRING IN BLDG NO EW11 AND SPECIAL REPAIR TO ROOFING FALSE CEILING AND FLOORING/PLASTERING WORK AND ELECTRIC REWIRING IN B
2024_MES_637222_1
GE/DNR/T-66 OF 2023-24 / 8744/E8
Open Tender
Civil Works
Item Rate
180 days
BARAUNI
AS PER NIT
8 documents required · 8 mandatory
₹500
GE DANAPUR
₹82,700
Yes
12 Feb 2024
13 Jan 2024
5 Feb 2024
13 Jan 2024
3 Feb 2024
29 Jan 2024
Amount
Dismantling of corrugated or semi corrugated Asbestos Cement (AC) sheets in roof covering complete all as specified and directed.
S & F of 6 mm thick asbestos cement corrugated or semi-corrugated sheets fixed with ‘L’ type or ‘J’ type or cranked hook bolts and washers as in roof covering, walls etc. complete all as specified and directed.
S & F of 6 mm thick asbestos cement two-piece adjustable plain wing ridge fixed with coach screws and washers as in roof covering, walls etc. complete all as specified and directed.
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M&L brick work using 'B' class brick built in cm (1:6) straight or curved on plan exceeding 6.00 mtr mean radius except brick complete all as specified and as directed.
Dismantling floor, hearth or wall, roof tiling including cement mortar bedding (but not backing), complete all as specified and as directed.
M & L 25 mm thick cement concrete (1:2:4), type B-1, using 20 mm graded stone aggregate as in floors including finishing the surface rough complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25 thick over 20mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed in coloured cement to match with the floor and polishing complete and all as specified and directed by EIC.
M&L Machine cut kota stone slab flooring 20-25 thick as a riser of step, skirting, dado and piller laid over 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry ad pointed in coloured cement to match with the floor and polishing complete and all as specified & directed by EIC.
Taking down cement plaster from brick/concrete surfaces including raking out joints, hacking for key and scrubbing down with water etc all as specified and directed.
M&L for Rendring 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall & concrete and applying 2 mm thick wall care putty including preparation complete all as specified and as directed
M & L preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for applying 2mm thick Birla / JK Putty in two layers on old wall ceiling surfaces including complete removal of existing finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete all as specified and directed.
M & L for applying two coats of oil bound distemper on old plastered wall surfaces complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified and directed.
M&L Preparing old wooden surfaces exceeding 10Cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
M&L False ceiling of armstrong with aluminium laminated coating on reverse side, sound absorbing of size 60 x 60 cms, 6 mm thick arm gyp coloured with perforations supported on mild steel powder coated snap grid frame work with supporting hangers comprising GI wire 4 mm dia with size of grid 605 x 605 mm consisting of main and cross tee complete all as aper manufacturer instructions and as directed by Engr-in-Charge. Make:- Armstrong
M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete.
M & L for preparation of old steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint complete.
Cutting holes into or through brick or concrete wall, built in cement mortar superficial area n.exc 150 Sqcm including making good in CM 1:4 complete all as specified and directed.
S & F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 Sqm complete all as specified and directed.
Taking down chowkat with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
M & L for 2nd class hard wood (SAL) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats complete all as specified and directed.
S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (with sash bars) divided into squares, with plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkats for door etc complete, size of member of shutter as specified in SSR Part -I, Sec 8, clause 8.20 (b) complete all as specified and directed.
S& F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and directed...
S&F aluminum alloy anodised sliding door bolts with hasp & staple & fixing clips of sheet cast extruded section & fixing bolts & sliding bolts of extruded section 300 mm long complete all as specified and directed.
S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as spd.
S&F mild steel, 150mm long ordinary helical door spring incl roller and roller plate complete all as specified and directed
S&F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed
S&F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified.
S & F of 150 mm size (Overall length of cover plate) floor door stopper of aluminium body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
S&F in repair Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks etc complete all as spd.
S&F Mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, cooler stands and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe – 290 Gde E -- 165 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate for insertion of hold fast incl necessary form work etc complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in floor/plinth protection laid in suitable panels finished even and fair all as spd . 6mm Joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 gde and three part of sand ( all by weight) complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed.
M & L for old size brick work with sub class 'B' bricks laid flat in floors laid in dry complete all as specified and directed .
M&L for 100 mm thick PCC type C2, 1:3:6 (40 mm graded stone aggregate) finished even & fair complete all as spd and as directed
M&L for 55 mm thick PCC type B1, 1:2:4 (20 mm graded stone aggregate) finished even & fair complete all as spd and as directed
M&L for Rubber moulded coloured PCC chequered tile 20cm x 20 cm x 20-22 mm thick set, jointed and pointed in neat cement slurry in floors (with grey cement and pigments) including Screed bed 20mm thick or bedding of mortar (CM 1:6).
S & F of 35 mm thick factory made plain, framed, panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per IS – 1003 (Part – I) made of kiln seasoned & chemically pressure treated 2nd class hardwood complete all as specified and directed.
M&L PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings including form work complete all as directed by Engr-in-Charge.
Excavation in post hoes (or similar hole )each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layer not exceeding 25 cm
S & F steel work in tubular trusses incl spl shaped washer etc. Complete using ERW or induction built welded tubes confirming.
S&F pre-painted galvalume aluminium zinc coating GI based semi-corrugated steel sheet 0.50mm thick of colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by E-in-Charge
Taking down carefully copper / aluminium point wiring (light, fan, switch,socket or power, Bell & Two way point) complete with fitting such as switches, sockets, ceiling rose,sketch light fittings etc, and making good the disturbed surface of walls and floors etc complete all as specified and directed.
Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.
M & L for Point wiring in repairs with PVC insulated unsheathed electric FRLS cable 1100 volts grade, single core, having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including concealed conduit non metallic PVC 20 mm bore with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor connected to earth dolly by providing suitable lugs complete iincluding MS Galvanised boxes 1.6mm thick with 3mm thick laminatedsheet for mounting switches sockets etc complete all as specified and directed. for the following. Make of Cable : Polycab/Havell's/ Finolex and Make of PVC conduit : Plaza/Kalinga Premium/AKG :-
All as per item No 54 but one light/fan bell point controlled by one switch complete all as specified & directed
All as per item no 54 above but one 5 Amps socket out let point controlled by one switch on same board with other switches.
All as per item no 54 above but one 5 Amps socket out let point on independent board controlled by one switch.
All as per item no 54 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
Supply and fixing switch piano flush button single pole one way 5 amps, 240 Volts complete all as specified and directed.
Supply and fixing socket outlet flush type 5 Amps, 5 pin, 240 Volts complete all as specified and directed.
Supply and fixing switch piano flush button single pole one way 15 Amp 240 volt complete all as specified and directed.
Supply and fixing socket outlet flush type multipurpose 2 in 1, 3 pin 5 and 15 Amp, 240 volts complete all as specified and directed.
Supply and fixing Ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed.
Supply and fixing for batten/angular fittings complete all as specified and directed.
Supply and fix LED Lamp 7/8 watt complete all as specified and directed.
Supply and fixing for electronic Fan regulator 450 watt step type complete all as specified and directed.
Supply and fixing double door SPN DBs eight way of powder coated DB's suitable for MCB's fitted with bus bar,Neutral link,Earth bar and Din ral as per existing finishing complete all as specified and directed .
Supply and fixing with MCB SPN 5 to 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing MCB SP 240 volts 5 to 40 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing LED tube light batten box type with single tube 1x 18/20 watt T8 lamps type with one nos. LED tube rod of 18/20 Watt complete with both end bi-pin holder and all accessories internally pre wired and fixed to wall/ceiling incl fittings accessories and connecting with all accessories with twin core twisted flexible copper conductor cable suitable size all as specified and directed. Make- Havells/ Bajaj/Philips/Crompton/Eveready.
M&L for Sub main wiring four run of single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in & including non metallic rigid PVC conduit 20 mm bore including PVC insulated unsheathed two run of 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete.
Supply and fixing of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete
M/S Priya Trading Agency
HARINANDAN RAI SONS
M/S ANAND MOHAN ENTERPRISES
M/S PRAVIN ENTERPRISES
jaglalchoudharyandsons
M/s Mukesh and company
ANAHITAS INFOSOLUTIONS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .