GEMC-511687706662915
Awarded to WARSI MEDICO SYSTEM AND SERVICES
₹3.9 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| RADIANT WARMER | WARSI IMPEX -R-W | - | 10 NOS | ₹38,500 | 385,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹4.7 L+₹85,000 (22.1%)Qualified Make: zeal
Model: ZEAL REDIANT WARMER A 1 3 A 1 3 ALIGANJ ALIGANJ LUCKNOW UTTAR PRADESH 226024 | LUCKNOW | UTTAR PRADESH | 226024 | Make: zeal
Model: ZEAL REDIANT WARMER | L2 | Qualified | |
| 2 | L3₹4.8 L+₹90,000 (23.4%)Qualified Make: Alliance
Model: AM-INFW-10 JOSHI NAGAR LUDHIANA PUNJAB 141001 | LUDHIANA | PUNJAB | 141001 | Make: Alliance
Model: AM-INFW-10 | L3 | Qualified MSE | |
| 3 | Qualified Make: WARSI
Model: WARSI IMPEX -R-W 10 122 KATRA MADARI KHAN MOTI KATRA AGRA AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | Make: WARSI
Model: WARSI IMPEX -R-W | - | Qualified MSE | |
| 4 | L1₹3.9 LDisqualified Make: ACCUMAX
Model: AI-109 10 106 AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | Make: ACCUMAX
Model: AI-109 | L1 | Disqualified MSE | |
| 5 | Disqualified Make: NA
Model: ISIC & ISI-16C A 158 DDA SHED OKHLA INDUSTRIAL AREA PHASE 2 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: NA
Model: ISIC & ISI-16C | - | Disqualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
13 Aug 2018, 2:00 pmClosed
Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 3 Year (s) Clinical Incubators Or Infant Warmers ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Definition and Clinical Purpose Definition Mains electricity (AC- powered) mobile device that contains an infrared (IR) heating element(s) designed to emit controlled
evenly distributed overhead heat to the body of a newborn/infant patient requiring supplemental heat. This device is equipped with wheels so that it can easily be moved to different areas of a room
ward
or department. * Clinical purpose &Overview of functional requirements It is an electrically powered device with a radiant heating source intended to maintain * 1/10 the thermal balance of an infant by direct radiation of energy in the infrared region of the electromagnetic spectrum. It is a microprocessor controlled unit with heater placed on the over head panel. This work on both servo and manual mode options to maintain the baby temperature at the set value. There are two modes of operation manual and baby (servo) mode. It has Digital displays reading the set and baby observed temperatures seperately. Technical Characteristics (specific to this type of device) facility to display skin set
skin observed temperature in degree C and heat power separately true * have user friendly touch panel control Yes * Type of heater: ceramic ceramic
quartz infrared
calrod heater Audiovisual alarm facility for: Overheating beyond set temperature range
Spurt in Heater output i.e. more than 60% heater output for 10 minutes system should raise alarm and cutoff heater
Power failure
Heater failure
Patient temperature less/Greater than required/set temperature
Probe failure Overheating beyond set temperature range
Probe failure Warmer head should be rotatable in different direction
so as to allow taking X-ray true true
false Observation light Luminance and Colour temperature > = 1000 Lux
Colour temperature range from 3700K to 5100K * 2/10 Battery back up facility for Power failure indication during power fail Yes * desired temperature range 25 to 40 degree C * setable temperature 32 to 38 deg C 32 to 38 deg C * temperature resolution should be: <= 0.1 degree C * Temperature accuracy should be <= 0.2 degree C * facility to lock the keyboard to avoid unwanted user modification of the set parameters Yes * should have separate Bassinet trolley
bed should be tilt-able and have suitable provision for x-ray cassette holder
Mattress foam density should be minimum 25 kg/cm3
transparent collapsible side walls easily detachable for cleaning Yes * Should have a Feather Touch operation with large digital display and comprehensive alarms
Control Panel should be liquid proof and allow easy and hygienic disinfection Yes * Manual Mode can adjust Heater Output 10 -100 %
with 10% increment
an auditory and visual alarm shall be given at least every 15 min Yes * Under manual mode
heater cut off/switch off
if the maximum irradiance at any point of the mattress area exceeds a total irradiance level of 10 mW/cm2 (between 10 to 30 minutes) Yes * 3/10 Bed height from Floor - * Bed Distance from the heat source - * should have lockable castor wheels Yes * Green indicator light shall be indicate that warmer is ready for normal use Yes * Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray Yes * Number of tubing ports (edges covered by silicon rings) on the side walls (For cable management) 4 * Height of the side walls over the mattress 145 * Provision of X-Ray cassette tray of at least 750 mm X 350 mm size
suitable to adopt <= 20mm thick X-Ray cassette Yes * bay bed should be crevice free for ease of cleaning
infection control Yes * mattress used should be of biocompatible material Yes * Skin temperature probe should be small in size [Diameter <= 10 mm & Height <= 4 mm] with biocompatible Baby contact material Yes * Mobility
portability On castors (2 of the castors should have brakes) & Castor size >= 4 inch. * Settings Settings with facility to clearly display the selected mode
Option of Selecting either Manual mode and Baby (Servo) mode settings
Yes * 4/10 Provision for Set temperature range (in servo mode) from 32 to 38 deg C User's interface Manual and Servo controlled temperature regulation * Software and/or standard of communication(where ever required) LED Display and inbuilt software; Interruption and restoration of the power supply does not change the preset values * Others: 1. Device shall not overbalance when placed in any transport position of normal use on a 10° inclined plane from the horizontal plane. 2. Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding. 3. Patient leakage current should be less than 100 μA in normal condition 4. Temperature on the baby mattress should not exceed 43 deg C when the warmer is operating under steady temperature condition 5. Temperature of HEATER GUARDS should not exceed 85 °C in normal use. 6. The Temperature differences on the mattress shall not exceed 2 °C. * PHYSICAL CHARACTERISTICS Overall Height of equipment 1890 * Overall Width of equipment - * Overall Length of equipment - * Overall weight of equipment - * Heat source Configuration >= 60 degree angle adjustment must be * 5/10 possible in the heat source
it should provide shielding to the infant in case of breakage of tubes/bulbs and all surfaces to be made of corrosion resistant material Noise Auditory alarm shall have a sound level of at least 65 dBA at a distance of 3 m from the front of the infant radiant warmer
and the sound level of the alarm shall not exceed 80 dBA on the mattress * Heat dissipation Should maintain desired set temperature and uniform heat distribution in baby cradle * ENERGY SOURCE Power Requirements 220 to 240V
50 Hz AC
± 10% of input * Battery operated Power failure indication during power fail * Protection OVP
earth leakage protection * Power consumption 800 * Compatible to alternate energy supply source; Solar Heating in addition to AC power source): true true
false Thermal reflector to fix the skin probe >= 50 units to be supplied with each equipment unit * ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATIONS Atmosphere Ambiance Operating condition: -Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances. - an ambient air velocity is less than 0.3 m/s. * User's care
Cleaning
Disinfection & Sterility issues Complete unit to be easily washable and sterilizable using both * 6/10 alcohol and chlorine agents. STANDARDS AND SAFETY Certificates
CE European * Performance and safety standards (specific to the device type); Local and/or international IEC-60601-1-2:2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests (Or Equivalent BIS). Shall neet IEC 60601 -2- 21: 2009 Medical Electrical Equipment - Part 2¬21: Particular Requirement for the basic safety and essential performance of infant radiant warmers . should meet IEC 60601-1:2005(or latest) standard requirements. Baby contact material should be biocompatible. Manufacturer should be ISO 13485 certified * Availability of Type Test report from any Govt/NABL accredited iLAC approved laboratory (To be produced by Seller on Buyer's demand if indicated available) true * TRAINING AND INSTALLATION Pre-installation requirements for the equipment Availability of 5 amp/15 Amp. Electrical socket (2 nos) for each warmer at Buyer's facility. * Documentation required to be provided by Seller: User & Operating manual
Certificate of Calibration
Factory inspection report
user training manual * WARRANTY Warranty Scope Shall be onsite and comprehensive i.e. with free service and spares * Warranty period for equipment(Other than nickel chrome 3 3
5 (or higher) 7/10 wire filament and tube of quartz
that shall have lifetime warranty) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subodh Kumar Goyal 160016
GMSH-SECTOR 16
CHANDIGARH 10 15
397429
GEM/2018/B/56249
GeM Contract
Clinical incubators or infant warmers
GeM Contract
15 days
Chandigarh; Chandigarh
PRODUCT
Awarded to WARSI MEDICO SYSTEM AND SERVICES
₹3.9 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| RADIANT WARMER | WARSI IMPEX -R-W | - | 10 NOS | ₹38,500 | 385,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 4 Lakh (s) Experience with Gov. Required 3 Year (s) Clinical Incubators Or Infant Warmers ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Definition and Clinical Purpose Definition Mains electricity (AC- powered) mobile device that contains an infrared (IR) heating element(s) designed to emit controlled | - | - | - |
| evenly distributed overhead heat to the body of a newborn/infant patient requiring supplemental heat. This device is equipped with wheels so that it can easily be moved to different areas of a room | - | - | - |
| ward | - | - | - |
| or department. * Clinical purpose &Overview of functional requirements It is an electrically powered device with a radiant heating source intended to maintain * 1/10 the thermal balance of an infant by direct radiation of energy in the infrared region of the electromagnetic spectrum. It is a microprocessor controlled unit with heater placed on the over head panel. This work on both servo and manual mode options to maintain the baby temperature at the set value. There are two modes of operation manual and baby (servo) mode. It has Digital displays reading the set and baby observed temperatures seperately. Technical Characteristics (specific to this type of device) facility to display skin set | - | - | - |
| skin observed temperature in degree C and heat power separately true * have user friendly touch panel control Yes * Type of heater: ceramic ceramic | - | - | - |
| quartz infrared | - | - | - |
| calrod heater Audiovisual alarm facility for: Overheating beyond set temperature range | - | - | - |
| Spurt in Heater output i.e. more than 60% heater output for 10 minutes system should raise alarm and cutoff heater | - | - | - |
| Power failure | - | - | - |
| Heater failure | - | - | - |
| Patient temperature less/Greater than required/set temperature | - | - | - |
| Probe failure Overheating beyond set temperature range | - | - | - |
| Probe failure Warmer head should be rotatable in different direction | - | - | - |
| so as to allow taking X-ray true true | - | - | - |
| false Observation light Luminance and Colour temperature > = 1000 Lux | - | - | - |
| Colour temperature range from 3700K to 5100K * 2/10 Battery back up facility for Power failure indication during power fail Yes * desired temperature range 25 to 40 degree C * setable temperature 32 to 38 deg C 32 to 38 deg C * temperature resolution should be: <= 0.1 degree C * Temperature accuracy should be <= 0.2 degree C * facility to lock the keyboard to avoid unwanted user modification of the set parameters Yes * should have separate Bassinet trolley | - | - | - |
| bed should be tilt-able and have suitable provision for x-ray cassette holder | - | - | - |
| Mattress foam density should be minimum 25 kg/cm3 | - | - | - |
| transparent collapsible side walls easily detachable for cleaning Yes * Should have a Feather Touch operation with large digital display and comprehensive alarms | - | - | - |
| Control Panel should be liquid proof and allow easy and hygienic disinfection Yes * Manual Mode can adjust Heater Output 10 -100 % | - | - | - |
| with 10% increment | - | - | - |
| an auditory and visual alarm shall be given at least every 15 min Yes * Under manual mode | - | - | - |
| heater cut off/switch off | - | - | - |
| if the maximum irradiance at any point of the mattress area exceeds a total irradiance level of 10 mW/cm2 (between 10 to 30 minutes) Yes * 3/10 Bed height from Floor - * Bed Distance from the heat source - * should have lockable castor wheels Yes * Green indicator light shall be indicate that warmer is ready for normal use Yes * Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray Yes * Number of tubing ports (edges covered by silicon rings) on the side walls (For cable management) 4 * Height of the side walls over the mattress 145 * Provision of X-Ray cassette tray of at least 750 mm X 350 mm size | - | - | - |
| suitable to adopt <= 20mm thick X-Ray cassette Yes * bay bed should be crevice free for ease of cleaning | - | - | - |
| infection control Yes * mattress used should be of biocompatible material Yes * Skin temperature probe should be small in size [Diameter <= 10 mm & Height <= 4 mm] with biocompatible Baby contact material Yes * Mobility | - | - | - |
| portability On castors (2 of the castors should have brakes) & Castor size >= 4 inch. * Settings Settings with facility to clearly display the selected mode | - | - | - |
| Option of Selecting either Manual mode and Baby (Servo) mode settings | - | - | - |
| Yes * 4/10 Provision for Set temperature range (in servo mode) from 32 to 38 deg C User's interface Manual and Servo controlled temperature regulation * Software and/or standard of communication(where ever required) LED Display and inbuilt software; Interruption and restoration of the power supply does not change the preset values * Others: 1. Device shall not overbalance when placed in any transport position of normal use on a 10° inclined plane from the horizontal plane. 2. Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding. 3. Patient leakage current should be less than 100 μA in normal condition 4. Temperature on the baby mattress should not exceed 43 deg C when the warmer is operating under steady temperature condition 5. Temperature of HEATER GUARDS should not exceed 85 °C in normal use. 6. The Temperature differences on the mattress shall not exceed 2 °C. * PHYSICAL CHARACTERISTICS Overall Height of equipment 1890 * Overall Width of equipment - * Overall Length of equipment - * Overall weight of equipment - * Heat source Configuration >= 60 degree angle adjustment must be * 5/10 possible in the heat source | - | - | - |
| it should provide shielding to the infant in case of breakage of tubes/bulbs and all surfaces to be made of corrosion resistant material Noise Auditory alarm shall have a sound level of at least 65 dBA at a distance of 3 m from the front of the infant radiant warmer | - | - | - |
| and the sound level of the alarm shall not exceed 80 dBA on the mattress * Heat dissipation Should maintain desired set temperature and uniform heat distribution in baby cradle * ENERGY SOURCE Power Requirements 220 to 240V | - | - | - |
| 50 Hz AC | - | - | - |
| ± 10% of input * Battery operated Power failure indication during power fail * Protection OVP | - | - | - |
| earth leakage protection * Power consumption 800 * Compatible to alternate energy supply source; Solar Heating in addition to AC power source): true true | - | - | - |
| false Thermal reflector to fix the skin probe >= 50 units to be supplied with each equipment unit * ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATIONS Atmosphere Ambiance Operating condition: -Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances. - an ambient air velocity is less than 0.3 m/s. * User's care | - | - | - |
| Cleaning | - | - | - |
| Disinfection & Sterility issues Complete unit to be easily washable and sterilizable using both * 6/10 alcohol and chlorine agents. STANDARDS AND SAFETY Certificates | - | - | - |
| CE European * Performance and safety standards (specific to the device type); Local and/or international IEC-60601-1-2:2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility -Requirements and tests (Or Equivalent BIS). Shall neet IEC 60601 -2- 21: 2009 Medical Electrical Equipment - Part 2¬21: Particular Requirement for the basic safety and essential performance of infant radiant warmers . should meet IEC 60601-1:2005(or latest) standard requirements. Baby contact material should be biocompatible. Manufacturer should be ISO 13485 certified * Availability of Type Test report from any Govt/NABL accredited iLAC approved laboratory (To be produced by Seller on Buyer's demand if indicated available) true * TRAINING AND INSTALLATION Pre-installation requirements for the equipment Availability of 5 amp/15 Amp. Electrical socket (2 nos) for each warmer at Buyer's facility. * Documentation required to be provided by Seller: User & Operating manual | - | - | - |
| Certificate of Calibration | - | - | - |
| Factory inspection report | - | - | - |
| user training manual * WARRANTY Warranty Scope Shall be onsite and comprehensive i.e. with free service and spares * Warranty period for equipment(Other than nickel chrome 3 3 | - | - | - |
| 5 (or higher) 7/10 wire filament and tube of quartz | - | - | - |
| that shall have lifetime warranty) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Subodh Kumar Goyal 160016 | - | - | - |
| GMSH-SECTOR 16 | - | - | - |
| CHANDIGARH 10 15 | - | - | - |
Exempted
15 Oct 2018
24 Sept 2018
contract_GEMC-511687706662915.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_397429.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .